flame5000_st-1125-2008.jpg
Images (1) Videos (0)
360° (0) Interactive (0)

Product features

Easy to install
The detector is very easy to install using a stainless steel mounting bracket which swivels to ensure that the device is always optimally aimed towards potential sources of fire. Installation is further simplified when using the video output as instant verification of correct positioning and alignment is given visually.
Flexible outputs
With built in relays, the Flame 5000 can be operated as a stand alone alarm device with no need for further control equipment. Alternatively it can be integrated in to a control system using its 3 relay out puts, or a 0 to 20 mA signal. Although the Flame 5000 transmits live video images, it is not necessary to utilise them, the transmitter will still be a fully functioning flame detector. In addition, a built in memory card allows recording before and after an alarm to give event analysis to the user.
Safe and fast intervention
Live video provides instant visual verification of fire eliminating the need to send personnel in to potentially hazardous situations, and reducing the risk of injury. An optical verification facility checks the window for contamination and ensures its field of view is not compromised by obstructions placed immediately in front of the detector.
Highly visible LED status indication
A highly visible three coloured LED is positioned at the front of the Flame 5000. This enables quick status indication in the field without the need to visit the control panel. Green indicates normal operation, yellow indicates fault, and red indicates the presence of flame.
Maximum field of view and detection range
The Dräger Flame 5000 can detect fires of 0.1 m² or greater at a distance of 44 m within a 90° horizontal field of view. The detector’s Field of View is a rectangular pyramid shape and represents a radial projection of the sensing element; this gives it the greatest standard coverage area and range of any flame detector currently available.
Immunity against false alarms SIL 2 Verified
The image processing algorithms of the Dräger Flame 5000 are so sophisticated that false alarms commonly associated with infra red or ultra violet flame detectors are eliminated. This false alarm immunity makes the Flame 5000 suitable for SIL 2 applications.
Worldwide approvals
With FM, CFM, IECEx and ATEX approval, the Flame 5000 is accepted world wide. This acceptance is enhanced with a range of metric and imperial threads, and both PAL and NTSC video modes.

Related Products

Flame Detection

Dräger FS-5000
Dräger FS-5000

The Dräger FS-5000 is used to simulate the presence of fire or flames to test the correct operation of the Dräger Flame 5000 CCTV Detector.

flame1300_st-341-2004.jpg
Dräger Flame 1300

The Dräger Flame 1300 is an explosion-proof infrared flame detector for detection of organic substance fires such as hydrocarbon fuels. The Flame 1300 offers reliable and fast detection of flames with high immunity to false alarms

flame1700_st-341-2004.jpg
Dräger Flame 1700

The Dräger Flame 1700 is an explosion-proof ultraviolet flame detector for detection of fires in substances that emit ultraviolet radiation such as hydrogen, silicon hydride (silane) or metals. The Flame 1700 offers reliable and fast detection of flames with high immunity to false alarms

flame2300_st-341-2004.jpg
Dräger Flame 2300

The Dräger Flame 2300 is an explosion-proof combined UltraViolet/InfraRed flame detector, which detects fires of substances that emit infrared and ultraviolet radiation such as hydrocarbon fuels. The Flame 2300 offers reliable and fast detection of flames with high immunity to false alarms

Flammable Detection

polytron_pulsar_st-3932-2005.jpg
Dräger Polytron Pulsar 2

The Dräger Pulsar 2 is an open path infrared gas detector. Representing the very latest advances in open pat technology – the Dräger Polytron Pulsar 2 is intended for the detection of a range of gaseous hydrocarbons. This includes the alkane series from methane to hexane, propylene, ethylene, methanol and ethanol. Equipped with either a terminal box or a certified cable entry point, the detector incorporates flexible installation.

pir7200_st-11660-2007.jpg
Dräger PIR 7200

The Dräger PIR 7200 is an explosion proof infra red gas detector for the continuous monitoring of carbon dioxide (CO2) Reliable in the harshest environments – the infrared-optical transmitter Dräger PIR 7200 offers drift-free optics for accurate CO2 detection.

Toxic Detection

Dräger Polytron 7000
Dräger Polytron 7000

The Dräger Polytron 7000 is an intrinsically safe gas detector for the continuous monitoring of toxic gasses and oxygen. With its unique modular design and total flexibility: The Dräger Polytron 7000 is a truly universal transmitter that can satisfy all toxic and oxygen measurement applications on a single platform. SIL 2 Approval guarantees no unrevealed failures.

polytron2xptox_st-1392-2006.jpg
Dräger Polytron 2 XP Tox

The Dräger Polytron 2 XP Tox is an explosion proof gas detector for continuous monitoring of toxic gases and oxygen in ambient air. The transmitter converts the signal from an electrochemical sensor to 4 to 20 mA analog, HART® or RS 485 digital signal output. The unit is designed for one-man calibration, and offers a variety of diagnostics and self test features.

Control Systems

regard_2-669-95.jpg
Dräger REGARD control system

Tried and tested thousands of times and infinitely flexible. The modular Regard control system can be individually adapted to any monitoring task. Suitable for SIL 2 systems, the Regard system is also ATEX approved, and meets EMC directive standards.

Regard-3900.jpg
Dräger REGARD 3900

The Regard 3900 is a standalone, autonomous control system for up to 16 gas detectors. It is fully configurable and monitors the concentration of toxic gases, oxygen and combustible gases and vapours.

Accessories

flammensimulator_fs5000_st-8006-2008.jpg
Flame Simulator Dräger FS-5000

Flame simulator for the testing of flame detectors which evaluate video signals (CCTV)

Order no.: 420 93 07

System Components

regard_2-669-95.jpg
Dräger REGARD control system

Tried and tested thousands of times and infinitely flexible. The modular Regard control system can be individually adapted to any monitoring task. Suitable for SIL 2 systems, the Regard system is also ATEX approved, and meets EMC directive standards.

Regard-3900.jpg
Dräger REGARD 3900

The Regard 3900 is a standalone, autonomous control system for up to 16 gas detectors. It is fully configurable and monitors the concentration of toxic gases, oxygen and combustible gases and vapours.

regard2400_st-5647-2006.jpg
Dräger REGARD 2400 and REGARD 2410

Whether they are mounted to a wall or integrated in the switch cabinet - the flexible small control units Regard 2400 and Regard 2410 reliably monitor the concentration of toxic gases and oxygen as well as combustible gases and vapours.

regard_1_st-335-2004.jpg
Dräger REGARD-1

Robust, reliable and very cost effective. The compact Regard-1 is a complete standalone system for the control of a single gas detector; suitable for monitors of toxic gases, oxygen, combustible gases and vapours.

Product Information

Literature

Brochure: Gas List 2011 (PDF)

List of detectable gases and vapours.

Brochure: More than the sum of their components (PDF)

For over 70 years, Dräger has been one of the technology leaders in gas detection.

Brochure: At the heart of gas detection systems (PDF)

When there’s danger in the air ... this can quickly pose a high risk to humans, the environment, and all types of property and systems. Recognize the threat before it is too late.

Brochure: Functional Safety and gas detection systems (PDF)

Safety Instrumented Systems are used to reduce the risk for the protection of people, plants, and environment.

Brochure: Explosion protection and gas detection systems (PDF)

Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion protection measures it may be preferable to detect them before they become ignitable.