CuffGuard is an automated continuous pressure regulator designed for precise inflation, continuous regulation, and automatic deflation of endotracheal tube (ETT) cuffs during ventilation therapy. Continuous cuff pressure control keeps the pressure around the setpoint and requires less hands-on time from staff. As a result, CuffGuard can help prevent ventilator-associated pneumonia (VAP) by maintaining optimal ETT cuff pressure.1
ETT cuff underinflation is a known risk factor for micro-aspiration and ventilator associated pneumonia (VAP). To prevent complications associated with both under- and over-inflation of the tracheal cuff, it is commonly used that cuff pressure should … More information
be maintained at approximately 25 cmH2O. But, despite routine manometer checks of the cuff pressure, under- and over-inflation are very common in intubated patients. To improve tracheal seal and prevent VAP, continuous cuff pressure control has been advised.1CuffGuard automatically measures and maintains the set ETT cuff pressure reliably and accurately (see technical data), preventing under- or over-inflation of the endotracheal cuff. The constant cuff pressure not only effectively protects the trachea … More information
from damage (e.g., oedema, necrosis)2, but also helps to prevent the risk of VAP. It eliminates the need to manually adjust ETT cuff pressure, resulting in less hands-on staff time. In the event of an accidental leak or extubation, CuffGuard provides an alarm.CuffGuard is simple and intuitive to use. During intubation, it provides automated and controlled cuff inflation at defined setpoint once the endotracheal tube is inserted. The ETT cuff pressure must be maintained within an optimal range. However, th … More information
is can change during ventilation (e.g., certain care procedures, coughing, ventilator asynchronies), CuffGuard will always regulate and maintain the ETT cuff pressure around the desired setpoint. It provides temporary over-inflation for specific procedures (e.g., patient hygiene, specific surgery, dental care). For extubation, it provides rapid and active deflation.The large colour display with automatic screen rotation is particularly easy to read. CuffGuard can be powered by mains, USB, and battery, allowing for versatile installation options. The mounting clamp allows for optimal positioning on a pole or rail of the ventilator.The disposable connecting tube with antibacterial filter helps prevent the risk of cross-contamination. A LUER connector on the ETT side ensures full compatibility with endotracheal tubes. The LUER lock connector on the CuffGuard side of the tube avoids the risk of accidental disconnection.1 Nseir S et al. Continuous control of tracheal cuff pressure for VAP prevention: a collaborative meta‑analysis of individual participant data. Ann. Intensive Care (2015) 5:43 DOI 10.1186/s13613-015-0087-32 Nazari R et al. The changes of endotracheal tube cuff pressure during manual and intermittent controlling in intensive care units. Iranian J Nursing Midwifery Res 2020;25:71-5.