Dräger Polytron® 3000

The Dräger Polytron® 3000 is an intrinsically safe gas detector for the continuous monitoring of toxic gases and oxygen in ambient air. It is the part of a new generation of gas detectors developed on a modular platform. Communication to the central control system is done via a 4 to 20 mA signal.

Simple, quick installation

The Polytron 3000 consists of two components, the dockingstation, for mechanical and electrical installation, and the Polytron 3000 transmitter. The dockingstation can be mounted and wired in advance, guarded against rain and dust by a modular cover until time of commissioning. During commissioning, the Polytron 3000 is simply inserted into the dockingstation and secured with a quick lock mechanism. After inserting the sensor, the system is ready for operation.

Wide range of applications

With its exceptional electromagnetic compatibility and a variety of mounting options, the CE marked Polytron 3000 is suitable for many different areas of application ranging from chemical to the semiconductor industries.

Easy to operate and maintain

The operation and maintenance of the Polytron 3000 is easy. The tried and tested DrägerSensor is equipped with an integrated data memory that contains all calibration information. This allows the Polytron 3000 to accept a pre-calibrated sensor, speeding up maintenance or sensor change. If preferred, the sensor can be field calibrated in the transmitter.

Explosion Protection

For global use the Polytron 3000 is approved according to ATEX, IECEx, UL and CSA.

Downloads

Product information: Dräger Polytron® 3000 (PDF)
Product information: Dräger Polytron® 3000 (PDF)

The Dräger Polytron® 3000 is an intrinsically safe gas detector for the continuous monitoring of more than 60 toxic gases and oxygen in ambient air. It is the part of a new generation of gas detectors developed on a modular platform. Communication to the central control system is done via a 4 to 20 mA signal.

Download

SIL Brochure, en
SIL Brochure, en

Safety Instrumented Systems are used to reduce the risk for the protection of people, plants, and environment.

Download

Fixed gas detectors, sensors and substances

Dräger fixed gas detectors can be used with different sensors and...

Search for substance

Please enter a substance

Product configurations

for the fixed gas detector Dräger Polytron 3000

Utilise for 46 Substances

16 matching DetectorFGDS

Technical Data

Key Facts

Type
Transmitter
Measuring Principle
Electrochemical
Cable entry
M20
Display
Intrinsic Safety
Flameproof
Increased Safety
SIL
✓ SIL 1 (IEC 61508-2)
4-20 mA
Bus
HART®
Wireless

Technical Data

Power Supply
12 to 30 V DC, 2-wire
Temperature (operation)
-40°C - 65°C
Humidity
0 to 100% r.h., non-condensing
Pressure (hPa)
700 - 1300
Dimensions (H × W × D)
16,6x13,5x12,9 cm
Weight
1,98 lb
Housing Material
Glass fibre reinforced polyester (GFRP)
Degree of protection (IP class)
IP66

Approvals

ATEX
IECEx
UL
CSA
CE marking
GOST (EAC)
Performance approval
Shipping approval (MED)