Dräger Polytron 5200 CAT

The Dräger Polytron 5200 CAT is a cost-effective, explosion-proof transmitter designed for detecting flammable gases and vapours. It uses the catalytic DrägerSensor Ex… DQ. Due to the 3-wire operation and the 4 to 20 mA analogue output, you can combine the transmitter with most evaluation systems in your gas detection system.

Fast and stable: The DrägerSensor Ex … DQ

The built-in type-DQ gas sensor is based on the proven catalytic bead measuring principle. It has excellent long-term stability with outstanding poison resistance. And this is the reason for its durability. Due to the novel gas inlet opening, the sensor responds to gas in only a few seconds. This allows you to react immediately with countermeasures and prevent the development of a flammable atmosphere.

Same design, same operating principle

The Dräger Polytron 5200 belongs to the Polytron 5000 series. All transmitters in this series have the same design and user interface. This allows for uniform operation with reduced training and maintenance requirements. The large graphic backlit display shows status information clearly and in an easy to use format. The measured gas concentration and measuring unit are displayed during normal operation. Coloured LEDs (green, yellow and red) provide additional alarm and status information. You can evaluate the sensor signal by using the 4 to 20 mA output. The Polytron 5200 is operated by means of a magnetic wand over contact surfaces.

Three relays for controlling external equipment

Upon request, the Dräger Polytron 5200 can also be supplied with three integrated relays. This enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm. Audible alarms, signal lights or similar devices can thus be controlled locally without an additional cable between the transmitter and central controller.

Safe, robust housing for every application

The Polytron 5200 is explosion-proof and conforms to explosion protection type "d". For the increased safety type 'e' protection, an additional terminal box is available. This also makes pre-assembly easier. Depending on the environmental conditions, you can choose the Dräger Polytron 5200 with either an aluminium or stainless steel housing.

Make the impossible possible with the remote sensor

The remote sensing head allows you to install the sensor separately from the transmitter. This allows you to simply place the sensor closer to the gas cloud in hard-to-reach locations. The display remains visible at eye level.

Downloads

Polytron-5200-CAT Product Information, en
Polytron-5200-CAT Product Information, en

The Dräger Polytron 5200 CAT is a cost-effective, explosion-proof transmitter designed for detecting flammable gases and vapours. It uses the catalytic DrägerSensor Ex… DQ. Due to the 3-wire operation and the 4 to 20 mA analogue output, you can combine the transmitter with most evaluation systems in your gas detection system.

Download

AI Polytron 5xx0/8xx0 Docking Station for e-version 9033242 ME
AI Polytron 5xx0/8xx0 Docking Station for e-version 9033242 ME

Download

IFU Polytron 5000 Series 9033903 ME
IFU Polytron 5000 Series 9033903 ME

Denne brugsanvisning er kun til oplysning. Brugsanvisningen, der følger med produktet, skal altid læses og følges.

Download

IFU SP Polytron 5xx0, Polytron 8xx0 - Notes on Approval - 4544300 en-me

Fixed gas detectors, sensors and substances

Dräger fixed gas detectors can be used with different sensors and...

Search for substance

Please enter a substance

Product configurations

for the fixed gas detector Dräger Polytron 5200

Utilise for 30 Substances

7 matching DetectorFGDS

Technical Data

Key Facts

Type
Transmitter
Measuring Principle
Catalytic Bead Sensor
Response time
Cable entry
M20 or 3/4" NPT
Display
Intrinsic Safety
Flameproof
Increased Safety
SIL
✓ SIL 2 (IEC 61508-2)
4-20 mA
Bus
HART®
Wireless

Technical Data

Power Supply
10 to 30 V, 3-wire
Temperature (operation)
-40°C - 80°C
Humidity
0 to 100 % r.h., non-condensing
Pressure (hPa)
700 - 1300
Dimensions (H × W × D)
28x15x13 cm
Weight
8,82 lb
Housing Material
Epoxy coated copper-free aluminum or stainless steel SS 316L
Degree of protection (IP class)
IP65/66/67

Approvals

ATEX
IECEx
UL
CSA
CE marking
GOST (EAC)
Performance approval
Shipping approval
FM