N,N-dimethylhydrazinC2H8N2

Details
CAS-No.:57-14-7
UN-No.:1163
EC-No.:200-316-0
Hazard identification number:663
Warning sign
  • 663
  • 1163
Hazard signs
GHS02
GHS05
GHS06
GHS08
GHS09
Occupational exposure limit
  • TWA (ppm) 0,01
  • TWA (mg/m3) 0,025
  • H: 225
    Highly flammable liquid and vapour
  • H: 301 + 311 + 331
    Toxic if swallowed, in contact with skin or if inhaled
  • H: 314
    Causes severe skin burns and eye damage
  • H: 335
    May cause respiratory irritation
  • H: 350
    May cause cancer. 
  • H: 411
    Toxic to aquatic life with long lasting effects
Melting point:-58 °C
Boiling Point:63 °C
Density (at 20 °C, if not notified otherwise):0,78 g/cm3
Ionization:7.29 ± 0.05 eV
Flash Point:-18 °C
Ignition Temperature:240 °C
Vapour Pressure (at 20 °C, if not notified otherwise):164 hPa
Lower Explosive Limit:2 Vol.-%
Upper Explosive Limit:20 Vol.-%
Hazardous Effects:C
diamond314

Details

Diamond-Red3Flammability: Flammable with normal temperature 
Diamond-Yellow1Instability: Instable when heated 
Diamond-WhiteSpecial: Water suitable as an extinguishing agent 
Diamond-Blue4Health: Extremely dangerous 
DG-EA:2WE
Also known as:
  • 1,1-Dimethylhydrazin
  • 1,1-Dimethylhydrazine
  • as-Dimethylhydrazine
  • C2H8N2
  • DHM
  • Dimazin
  • Dimazine
  • Dimethylhydrazin
  • DMH
  • N,N-Dimethylhydrazin
  • u-Dimethylhydrazine
  • UDMH
  • Unsymmetrical dimethylhydrazine

Suitable products for N,N-dimethylhydrazin C2H8N2

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Electrochemical sensor XS

DrägerSensor XS

  • Electrochemical sensor XS
  • ​monitoring of toxic gases and oxygen deficiency including hydrides, amines, organic vapours
  • compatible with: X-am 3000 and X-am 7000
  • measuring range: in vol.-% and ...

Gas Detection Tubes

Short-term Tubes

Dräger Short-term Tubes

  • Short-term Tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • display for clear readability of results
  • can be used in explosive areas
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Stationære gasdetektorer og sensorer

Detektor til giftige gasser og ilt

Dräger Polytron® 7000

  • Detektor til giftige gasser og ilt
  • ​Sensor: Elektrokemisk sensor
  • Installation: Indbygget sikkerhed
  • Interface: 4-20 mA, bus, HART ®
  • IP-klasse: 66/67 og SIL2
  • Specielt: Display
Detektor til giftige gasser og ilt

Dräger PointGard 2100

  • Detektor til giftige gasser og ilt
  • ​Sensor: Elektrokemisk sensor
  • Installation: Ikke eksplosionssikker
  • Interface: 4-20 mA, relæer
  • IP-klasse: IP 54
  • Specielt: Selvstændig gasmåler
Detektor til giftige gasser og ilt

Dräger Polytron® 5100 EC

  • Detektor til giftige gasser og ilt
  • ​Sensor: Elektrokemisk sensor
  • Installation: Med øget sikkerhed eller flammesikker
  • Interface: 4-20 mA, relæer
  • IP-klasse: IP 65/66/67
  • Specielt: Displays 
Detektor til giftige gasser og ilt

Dräger Polytron® 6100 EC WL

  • Detektor til giftige gasser og ilt
  • ​Sensor: Elektrokemisk sensor
  • Installation: Indbygget sikkerhed
  • Interface: Trådløs
  • IP-klasse: 66/67 og SIL2
  • Specielt: Trådløs 
Detektor til giftige gasser og ilt

Dräger Polytron® 8100 EC

  • Detektor til giftige gasser og ilt
  • ​Sensor: Elektrokemisk sensor
  • Installation: Øget sikkerhed eller flammesikker
  • Interface: 4-20 mA, relæer, bus, HART ®
  • IP-klasse: IP65/66/67 og SIL2
  • Specielt: ...
null

Electrochemical DrägerSensor®

Filters

Respirator filter Bayonet

Dräger X-plore® Bayonet

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore 3500 ...
Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...

Masks

Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40
Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Single-filter full-face mask

Dräger Panorama® Nova

  • Single-filter full-face mask
  • ​different thread connections: RA thread connection Rd40, PE thread connection M45x3, ESA plug-in connector, P Dräger plug-in connection
  • EPDM or silicone mask body, ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger X-plore® 6570

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • silicone mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • ​Dräger specific bayonet connection – lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...

Åndedrætsværn med turboenhed og filtre

Filters for PAPR

Dräger X-plore® 8000 Filters

  • Filters for PAPR
  • Particle, gas and combination filters available
  • To be used with powered air purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odour filter

null

Dräger X-plore® 8000

Protective Suits

Gas-tight suit

Dräger CPS 5800

  • Gas-tight suit
  • SCBA worn over the protective suit
  • four suit sizes (M-XXL)
  • diagonal zipper for donning without assistance
  • suit material Zytron® 500, limited use

Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat