propan-2-thiolC3H8S

CAS-No.:
75-33-2
UN-No.:
2402
EC-No.:
200-861-4
Hazard identification number:
33
Warning sign:
  • 33
  • 2402
Hazard signs
GHS02
GHS07
GHS09
  • H: 225
    Highly flammable liquid and vapour
  • H: 317
    May cause an allergic skin reaction
  • H: 410
    Very toxic to aquatic life with long lasting effects
  • Melting point:
    -131 °C
  • Boiling Point:
    53 °C
  • Density (at 20 °C, if not notified otherwise):
    0,82 g/cm3
  • Ionization:
    9,15 eV
  • Flash Point:
    -20 °C
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    300 hPa
  • Lower Explosive Limit:
    1,77 Vol.-%
  • Hazardous Effects:
    Ss

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for propan-2-thiol C3H8S

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Fixed Gas Detection and Sensors

Toxic Gases and Oxygen Detector

Dräger Polytron® 7000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: 4-20 mA, Bus, HART ®
  • IP class: 66/67 and SIL2
  • Special: Display
Toxic Gases and Oxygen Detector

Dräger Polytron® 5100 EC

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: displays 
Toxic Gases and Oxygen Detector

Dräger Polytron® 6100 EC WL

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: Wireless
  • IP class: 66/67 and SIL2
  • Special: Wireless 
Toxic Gases and Oxygen Detector

Dräger Polytron® 8100 EC

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: ...
Toxic Gases and Oxygen Detector

Dräger PointGard 2100

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Non-explosion proof
  • Interface: 4-20 mA, Relays
  • IP class: IP 66
  • Special: Self-contained gas monitor

Dräger X-node

Electrochemical Gas Detector

Electrochemical DrägerSensor®

  • Electrochemical Gas Detector
  • ​continuous monitoring of poisonous gases and oxygen
  • compatible with: Polytron 8100, Polytron 7000, Polytron 6100, Polytron 5100, Polytron 3000, PointGard ...

Filters

Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...
Respirator filter Rd90

Dräger X-plore® Rd90 Filters

  • Respirator filter Rd90
  • ​Dräger specific Rd90 connection
  • robust aluminium housing
  • to be used in combination with X-plore 4700 half masks
Respirator filter Bayonet

Dräger X-plore® Bayonet

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore 3500 ...

Masks

Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...
Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Single-filter full-face mask

Dräger Panorama® Nova

  • Single-filter full-face mask
  • ​different thread connections: RA thread connection Rd40, PE thread connection M45x3, ESA plug-in connector, P Dräger plug-in connection
  • EPDM or silicone mask body, ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • ​Dräger specific bayonet connection – lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...

Powered Air Purifying Respirator

Filters for PAPR

Dräger X-plore® 8000 Filters

  • Filters for PAPR
  • Particle, gas and combination filters available
  • To be used with powered air purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odour filter

null

Dräger X-plore® 8000

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat