Dräger Polytron® 5200 CAT
Contact usDräger Polytron® 5200 CAT
Flammable Gas Detectors
- Sensor: Catalytic bead sensor
- Installation: Increased Safety or flameproof
- Interface: 4-20 mA, Relays
- IP class: IP 65/66/67
- Special: Display
Fast and stable – the DrägerSensor Ex … DD
The latest generation type DD gas sensor is based on the proven catalytic bead principle. Innovative dual active elements result in good long-term zero stability. Dräger has raised the bar yet again for poison resistance. The resulting long service life provides low ownership costs. Measuring performance has also been improved. The innovative gas inlet allows the sensor to respond to gas within a matter of seconds.
Same design, same operating principle
Polytron 5200 belongs to the Dräger Polytron 5000 series. All transmitters in this series have the same design and user interface. This allows for uniform operation with reduced training and maintenance requirements.
The backlit display shows status information clearly with quick access to functions using a non-intrusive magnetic wand. The gas concentration and measurement unit are displayed during normal operation. Colored LEDs (green, yellow and red) provide additional alarm and status information.
Three relays for controlling external equipment
Upon request, the Dräger Polytron 5200 can also be supplied with three integrated relays. This enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm. Audio alarms, signal lights, or similar devices can thus be controlled locally without an additional cable between the transmitter and central controller.
Safe, robust housing for every application
Polytron 5200 features a Class I, Div. 1 rated explosion proof enclosure made from aluminum or stainless steel, making it suitable for a wide range of environmental conditions. A protection type “e” version includes a convenient docking station which allows installation in hazardous atmospheres without running conduit (where approved).
Make the impossible possible with the remote sensor
An available remote sensor condulet housing allows the sensor to be installed up to 30 meters (100 feet) away from the Polytron transmitter. The sensor splash guard with integrated tubing nipple permits one person to perform a full calibration of a remote mounted sensor from the transmitter.
Images and Videos
Downloads

Polytron 5200 CAT Product Information, en-us
The Dräger Polytron® 5200 CAT is a cost effective explosion proof transmitter for the detection of flammable gases in the lower explosion limit (LEL). It uses a catalytic bead DrägerSensor® Ex … DD, which will detect most flammable gases and vapors. A 3 wire 4 to 20 mA analog output with relays makes it compatible with most control systems.


PolySoft 1.11.0 Setup
Sensors and substances
Dräger Sensors for fixed gas detectors can be used to measure a large number of hazardous substances. Check the different sensors by searching for a substance. Get in contact with our experts to get more information.
Product configurations
Utilise for 29 Substances
6 matching SensorFGDS
Technical Data
Key Facts
- Type
- Transmitter
- Response time
- Cable entry
- M20 or 3/4" NPT
- Display
- ✓
- Intrinsic Safety
- ✗
- Flameproof
- ✓
- Increased Safety
- ✓
- SIL
- ✓ SIL 2 (IEC 61508-2)
- 4-20 mA
- ✓
- Bus
- ✗
- HART®
- ✗
- Wireless
- ✗
Technical Data
- Power Supply
- 10 to 30 V, 3-wire
- Temperature (operation)
- -40°C - 80°C
- Humidity
- 0 to 100 % r.h., non-condensing
- Pressure (hPa)
- 700 - 1300
- Dimensions (H × W × D)
- 0.28x0.15x0.13 m
- Weight
- 8.82 lb
- Housing Material
- Epoxy coated copper-free aluminum or stainless steel SS 316L
- Degree of protection (IP class)
- IP65/66/67
Approvals
- ATEX
- ✓
- IECEx
- ✓
- UL
- ✓
- CSA
- ✓
- CE marking
- ✓
- GOST (EAC)
- ✓
- Performance approval
- ✓
- Shipping approval
- ✗
- FM
- ✗