Compare

Dräger Polytron® 7000

Toxic Gases and Oxygen Detectors
  • Monitors toxic gases or oxygen
  • Offers flexibility to configure the transmitter to fit exact application
  • Uses proven electrochemical DrägerSensors optimised for industrial applications
Dräger Polytron® 7000 Toxic Gases and Oxygen Detectors
Dräger Polytron® 7000 Toxic Gases and Oxygen Detectors
Compare

Focus on Safety: Detect toxic gases and oxygen with precision

Quick Links
Specifications
Accessories
Downloads
Explore all substances
-40°C - 65°C
Temperature (operation)
Glass fibre reinforced polyester (GFRP)
Housing Material
C4H6, C4H10S, C3H8O, C2H4O, C2H4O2, C4H6O2, C2H2, NH3 and more
Substances
See all relevant substances
Open full specifications

Highlights

The Dräger Polytron® 7000 gas detector can satisfy all toxic gas and oxygen measurement applications on a single platform. It meets compliance requirements, as well as the high specification requirements of customized solutions.

Intuitive operation

Dräger developed the simple and structured operation concept of the Polytron 7000 in collaboration with its customers. The large graphic display shows status information with the help of pictograms and plain text and guides the user through calibrati More Information

Dräger Polytron® 7000 Toxic Gases and Oxygen Detectors -

Communication interfaces

The Polytron 4-20 mA signal can communicate with the control system using HART®, LON, PROFIBUS® or FOUNDATION Fieldbus™, and can take over the link between the Dräger Polytron 7000 and the control system. The modular design allows for the subsequent  More Information

Dräger Polytron® 7000 Toxic Gases and Oxygen Detectors -

Intelligent sensors

The Dräger Polytron 7000 can measure 100 different gases. The DrägerSensors that were specifically developed for year-round, permanent use in a stationary gas detection systems are known for their long life and the excellent measuring quality. The bu More Information

Software options

With three different software dongles, different functions can be built into the transmitter that adjust it to requirements specific to its use. With the sensor test dongle, the Dräger Polytron 7000 performs many different patented sensor tests that  More Information

Robust enclosure

The design of the compact, impact-resistant, fiber-glass reinforced plastic enclosure is guarded against dust and splashing in accordance with IP66/67. The transmitter has been approved according to the SIL2 specification and it offers highest resist More Information

Pump module

An internal pump that sends the gas mixture to the sensor is a further module option. The pump is an integral part of the Dräger Polytron 7000. Not to be used in hazardous areas.

Relay module

The Dräger Polytron 7000 can be equipped with a relay module. It can thus be used as an independent gas detection system with two concentration alarms and one interference alarm. Not to be used in hazardous areas.

Specifications

-40°C - 65°C
Temperature (operation)
Glass fibre reinforced polyester (GFRP)
Housing Material
C4H6, C4H10S, C3H8O, C2H4O, C2H4O2, C4H6O2, C2H2, NH3 and more
Substances
See all relevant substances

Key Facts

Type
Transmitter
Measuring Principle
Electrochemical
Cable entry
M20
Display
Intrinsic Safety
Flameproof
Increased Safety
SIL
SIL 2 (IEC 61508-2)
4-20 mA
Bus
HART®
Wireless

Technical Data

Power Supply
16.5 to 30 V DC 2-wire
Temperature (operation)
-40°C - 65°C
Humidity
0 to 100% r.h., non-condensing
Pressure (hPa)
700 - 1300
Dimensions (H × W × D)
16.6x13.5x12.9 cm
Weight
1.98 lb
Housing Material
Glass fibre reinforced polyester (GFRP)
Degree of protection (IP class)
IP66/67

Approvals

ATEX
IECEx
UL
CSA
CE marking
GOST (EAC)
Performance approval
Shipping approval (MED)

Dräger VOICE
Your hazmat-based safety product finder

Access relevant information and specific safety equipment recommendations for more than 1,500 hazardous substances.

See the whole Product System.

This product is part of a Dräger system solution. Combine it with the following system components.

Connective Products

Controller - Dräger REGARD 3000
Dräger REGARD 3000
  • Modular control system for various gas and vapour monitoring
  • Multi-coloured status light signals system status
  • Allows combination of Input, Relay, and Gateway modules
More Information
Controller - Dräger REGARD 3920
Dräger REGARD 3920
  • Standalone control system with up to 16 configurable measuring channels
  • Modular setup for plant-specific customization
More Information
Controller - Dräger REGARD 7000
Dräger REGARD 7000
  • Highly expandable control and analysis system
  • Monitors various gases and vapours
  • Suitable for complex gas warning systems
More Information
Sensors for Fixed Gas Detectors - Electrochemical (EC) DrägerSensor®
Electrochemical (EC) DrägerSensor®
  • Fast response, high accuracy, great stability, long life
  • Detects over 100 toxic gases and oxygen
  • Robust and long-life sensors
More Information

Accessories

Calibration adapter DrägerSensor AC
Calibration adapter DrägerSensor AC
Adapter for permanent gassing and the calibration of transmitters with electrochemical DrägerSensorAC. Also suitable for continual use in connection with the sampling unit.

Order No.: 6809380
Calibration bottle
Calibration bottle
For the calibration of electrochemical sensors (not type L). Creates a defined gas concentration when using Dräger test gas ampoules.

Order No.: 68 03 407
Docking station
Docking station
For the easy and time-saving mounting and commissioning of the Dräger Polytron 3000 or 7000. It is required for each Polytron 3000 or 7000.

Order No.: 83 17 990
Dräger Polysoft
Dräger Polysoft

Configuration and calibration software for the following stationary gas detection systems: PIR 7000, PIR 7200, Polytron 7000, including status and diagnosis functions.

Order No.: 83 23 405

Dräger Remote Sensor
Dräger Remote Sensor
For the remote operation of the sensor at a distance of up to 30 m. Suitable for wall and duct mounting depending on the accessories used.

Order No.: 83 17 275
Duct mount kit
Duct mount kit
Enables the mounting of the Dräger Polytron 7000 onto exhaust ducts or pipes. With 90° swings, the transmitter can be put into a user-friendly position.

Order No.: 83 17 150
Gassing adapter
Gassing adapter
Adapter for permanent gassing and the calibration of transmitters with electrochemical sensors (not type AC), catalytic sensors (pellistors) and transmitters of type Polytron IR CO2 and Polytron IR Ex HC. Also suitable for continual use in connection with the sampling unit.

Order No.: 68 06 978
Pump adapter DrägerSensor AC
Pump adapter DrägerSensor AC
Special pump adapter for the DrägerSensor AC. Only use in combination with the calibration adapter AC (Part No.: 6809380).

Order No.: 8317976
Rain guard Dräger Sensor AC
Rain guard Dräger Sensor AC
Guards the DrägerSensor AC against rain water

Order No.: 6809379
Splash guard DrägerSensor
Splash guard DrägerSensor
Guards the DrägerSensors against splashing water. Not suitable for the DrägerSensor AC.

Order No.: 6812510
Test Gas Ampule
Test Gas Ampule
Designed for use with the calibration bottle, these test gas ampules are available for the following gases/concentrations:

Test gas ampule / Order No.:
SO2 10 ppm / 68 07 763
SO2 50 ppm / 68 07 764
NO2 10 ppm / 68 07 765
NO2 50 ppm / 68 07 766
CO 100 ppm / 68 07 920
CO 300 ppm / 68 07 921
NH3 300 ppm / 68 07 923
NH3 50 ppm / 68 07 924
SO2 1 ppm / 68 07 925
SO2 4 ppm / 68 07 926
Cl2 8 ppm / 68 07 928
HCN 10 ppm / 68 07 929
H2S 10 ppm / 68 08 140
H2S 20 ppm / 68 08 141
H2S 40 ppm / 68 08 142
H2S 100 ppm / 68 08 143
Viton® Calibration Adapter
Viton® Calibration Adapter
The Viton® adapter is designed for zero-point tests and the calibration of transmitters with electrochemical sensors (not type AC), catalytic sensors (pellistors) and Polytron IR CO2 and Polytron IR Ex HC type transmitters.

Order No.: 68 10 536
Next Steps

Get in touch with Dräger

smiling woman
Draeger Safety Canada Ltd.
​2425 Skymark Ave, Unit 1 Mississauga, ON L4W 4Y6