Dräger Polytron® 8310 IR Flammable Gas Detectors

Dräger Polytron® 8310 IR

Contact us

Dräger Polytron® 8310 IR

The Dräger Polytron® 8310 IR is an advanced explosion proof transmitter for the detection of combustible hydrocarbon gases in the lower explosion limit (LEL). It uses an infrared DrägerSensor® IR that can be configured for methane, propane or ethylene. Besides a 3 wire 4 to 20 mA analog output with relays, it also offers HART®, Modbus and Fieldbus protocols making it compatible with most control systems.

Poison-resistant and fail-safe – the DrägerSensor® IR

​DrägerSensor IR is a cost-effective alternative to catalytic bead sensors while offering several benefits: It is poison-resistant against chemicals that can shorten a catalytic bead pellistor’s life. Long life optics result in lower maintenance costs compared to pellistors. IR technology is inherently fail-safe, meaning no unrevealed failures. Improved performance with excellent long-term stability and fast response times.

Easy device management via digital communication

The Dräger Polytron 8310 is equipped with digital interfaces allowing for quick and easy remote interrogation of the transmitter’s state. Integration with existing asset management systems such as PACTware is possible via DTM. In addition to the common HART® communication system, the fieldbus interfaces PROFIBUS® PA, FOUNDATION fieldbus H1, and Modbus RTU are also available.

Same design, same operating principle

The Dräger Polytron 8310 belongs to the Polytron 8000 series. All transmitters in this series have the same design and user interface. This allows for uniform operation with reduced training and maintenance requirements. The large graphic backlit display shows status information clearly and in an easy to use format. The measured gas concentration, selected gas type, and measuring unit are displayed during normal operation. Colored LEDs (green, yellow and red) provide additional alarm and status information. The Polytron 8310 is operated by means of a magnetic wand over contact surfaces.

Three relays for controlling external equipment

Upon request, the Dräger Polytron 8310 can also be supplied with three integrated relays. This enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm. Audible alarms, signal lights or similar devices can thus be controlled locally without an additional cable between the transmitter and central controller.

Safe, robust housing for every application

Polytron 8310 features a Class I, Div. 1 rated explosion proof enclosure made from aluminium or stainless steel, making it suitable for a wide range of environmental conditions.

Make the impossible possible with the remote sensor

The remote sensor connection housing allows you to install the sensor separately from the device electronics. This 'external' installation makes it easier to use if the sensor has to be installed in a difficult to access or unfavorable position.

Data logger

The Polytron 8310 has a data logger, which records measuring and event data from the past years. A graph function displays the history of the past 15 minutes on a time/concentration graph.

Downloads

Polytron 8310 IR Product Information, en-us
Polytron 8310 IR Product Information, en-us

Download

PolySoft V1.21.0 Setup
PolySoft V1.21.0 Setup

Download

AI Junction Box Ex d 4544286 ME
AI Junction Box Ex d 4544286 ME

Download

Dräger Polytron 8xx0 DD HART Simatic PDM for the firmware version: 3.2.1
Dräger Polytron 8xx0 firmware for bootloader version 4.0.4
Dräger Polytron 8xxx comDTM MB Setup V2.5.0
Dräger Polytron 8xxx DD FF AMS V4.0
Dräger Polytron 8xxx DD FF Field Connector V4.0
Dräger Polytron 8xxx DD HART® AMS 1.x R400.2.
Dräger Polytron 8xxx DD HART® AMS FW1.x
Dräger Polytron 8xxx DD HART® AMS FW2.0.x
Dräger Polytron 8xxx DD HART® Field Connector 475 FW1.x
Dräger Polytron 8xxx DD HART® Field Connector 475 FW2.0.x
Dräger Polytron 8xxx DD HART® PDM V2.0
Dräger Polytron 8xxx DD PB PDM V4.0
Dräger Polytron 8xxx DTM FF Setup V1.0.0.1054
Dräger Polytron 8xxx DTM HART® Setup V2.2.0.722
Dräger Polytron 8xxx DTM MB Setup V1.0.652.0
Dräger Polytron 8xxx DTM PB Setup V1.0.0.1054
Explosion Protection Brochure, en
Gas Dispersion Brochure, en
IFU Polytron 8000 series - Safety Manual - 9033307 en-us
IFU SP Polytron 5xx0, Polytron 8xx0 - Notes on Approval - 4544300 en-me
More than the sum Brochure, en
Polytron 8000 Device DTM (1.0.0.1054) for FF H1_
Polytron 8000 Device DTM (1.0.0.1054) for Profibus PA(003)
Polytron 8000 Device DTM (2.2.0.701) for 0x52_
Polytron 8xx0 HART Certificate of Registration, en
PROFIBUS PA system desciption, en
SIL Brochure, en

Fixed gas detectors, sensors and substances

Dräger gas detectors can be used with different sensors to detect a large number of hazardous substances. Check which sensor fits into this detector by searching for a substance. Contact our experts to get more information on our wide portfolio.

Search for substance

Please enter a substance

Product configurations

for the device Dräger Polytron 8310

Utilise for 16 Substances

2 matching Sensor(s)

Technical Data

Key Facts

Type
Transmitter
Response time
Cable entry
M20 or 3/4" NPT
Display
Intrinsic Safety
Flameproof
Increased Safety
SIL
✓ SIL 2 (IEC 61508-2)
4-20 mA
Bus
HART®
Wireless

Technical Data

Power Supply
10 to 30 V DC, 3-wire
Temperature (operation)
-40°C - 65°C
Humidity
0 to 100 % r.h., non-condensing
Pressure (hPa)
700 - 1300
Dimensions (H × W × D)
0.28x0.15x0.13 m
Weight
8.82 lb
Housing Material
Epoxy coated copper-free aluminum or stainless steel SS 316L
Degree of protection (IP class)
IP65/66/67

Approvals

ATEX
IECEx
UL
CSA
CE marking
GOST (EAC)
Performance approval
Shipping approval
FM

Compare with related Products

Get in touch with Dräger