Acetic AcidC2H4O2

Details
CAS-No.:64-19-7
UN-No.:2789
EC-No.:200-580-7
Hazard identification number:83
Warning sign
  • 83
  • 2789
Hazard signs
GHS02
GHS05
Occupational exposure limit
  • IDLH (ppm) 50
Occupational Exposure Limits may differ for your Province. Review your local Occupational Health and Safety Act for more information.
  • H: 226
    Flammable liquid and vapour

  • H: 314
    Causes severe skin burns
    and eye damage.
Melting point:17 °C
Boiling Point:118 °C
Density (at 20 °C, if not notified otherwise):1,05 g/cm3
Ionization:10.65 ± 0.02 eV
Flash Point:38.5 °C
Ignition Temperature:485 °C
Vapour Pressure (at 20 °C, if not notified otherwise):15,8 hPa
Lower Explosive Limit:6 Vol.-%
Upper Explosive Limit:17 Vol.-%
diamond20 2

Details

Diamond-Red2Flammability: Flammable when warm 
Diamond-Yellow0Instability: No danger for normal conditions 
Diamond-Blue2Health: Dangerous 
DG-EA:2P
Also known as:
  • Acetic acid (aqueous)
  • Dilute acetic acid
  • Ethanoic acid
  • Glacial acetic acid (pure compound)
  • H3C-COOH
  • Methanecarboxylic acid

Suitable products for Acetic Acid C2H4O2

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Multi-gas detector

Dräger X-am® 8000

  • Multi-gas detector
  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapors and oxygen

Multi-gas detector

Dräger X-am® 3500

  • Multi-gas detector
  • ​1 to 4 gas detection device
  • for clearance measurement
  • detection of flammable gases and vapours as well as O2, CO, H2S, NO2 and SO2
Multi-gas detector

Dräger X-am® 5000

  • Multi-gas detector
  • ​1 to 5 gas detection device
  • for personal air monitoring 
  • detection of flammable and toxic gases and organic vapours as well as oxygen and harmful concentrations
Multi-gas detector

Dräger X-am® 2500

  • Multi-gas detector
  • ​1 to 4 gas detection device
  • for personal air monitoring 
  • detection of flammable gases and vapours as well as O2, CO, NO2, SO2 and H2S
Catalytic Ex-Sonsors

Dräger Catalytic Ex-Sensors

  • Catalytic Ex-Sonsors
  • ​monitoring of explosive mixtures
  • high poisoning resistance to silicones and H2S
  • compatible with: X-am family
  • measuring range: lower explosion limit up to 100 vol.-%

Gas Detection Tubes

Short-term tubes

Dräger-Tubes® for short-term measurements

  • Short-term tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • can be used in explosive areas
  • highly visible end of measurement indicator
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Fixed Gas Detectors and Sensors

Flammable Gas Detectors

Dräger Polytron® 5200 CAT

  • Flammable Gas Detectors
  • ​Sensor: Catalytic bead sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: Display
Flammable Gas Detectors

Dräger Polytron® 8200 CAT

  • Flammable Gas Detectors
  • ​Sensor: Catalytic bead sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: Display
Toxic Gases and Oxygen Detector

Dräger Polytron® 8100 EC

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: ...
Toxic Gases and Oxygen Detector

Dräger Polytron® 5100 EC

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: displays 
Toxic Gases and Oxygen Detector

Dräger PointGard 2100

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Non-explosion proof
  • Interface: 4-20 mA, Relays
  • IP class: IP 54
  • Special: Self-contained gas monitor
Toxic Gases and Oxygen Detector

Dräger Polytron® 3000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: with Intrinsic Safety
  • Interface: 4-20 mA
  • IP class: IP66 and SIL1
  • Special: -
Toxic Gases and Oxygen Detector

Dräger Polytron® 7000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: 4-20 mA, Bus, HART ®
  • IP class: 66/67 and SIL2
  • Special: Display
null

Electrochemical (EC) DrägerSensor®

null

Catalytic Bead DrägerSensors®

Filters

Respirator filter Bayonet

Dräger X-plore® Bayonet Filter

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore ...

Dräger X-plore® Rd40 Filter

Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...

Masks

Single-filter full-face mask

Dräger Panorama Nova®

  • Single-filter full-face mask
  • ​​different thread connections: RA thread connection Rd40, PE thread connection M45x3, ESA plug-in connector, P Dräger plug-in connection
  • EPDM or silicone mask body, ...
Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • Dräger specific bayonet connection - lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...
Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40

Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...

Powered Air Purifying Respirators and Filters

Filters for PAPR

Dräger X-plore® 8000 Filters

  • Filters for PAPR
  • Particle, gas and combination filters available
  • To be used with powered air purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odour filter

null

Dräger X-plore® 8000

Protective Suits

Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use 

SPC 4700 with CVA 0700

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat