Dräger SensorAlive is a self-testing H2S sensor compatible with the Polytron 8100 transmitter and the PointGard 2100 standalone gas detection system running the latest firmware.
SensorAlive performs a LifeTest on a daily basis to check the function and sensitivity of the integrated electrochemical sensor. The LifeTest consists of two sequential activations of the gas generator, a sensitivity test, and an obstruction test of … More Information
the sensor using 2 internal nozzles. A single test takes about 8 minutes to complete. The complete LifeTest process, including the conditioning of the gas generator, performing two sequential tests, and evaluating the sensor data, extends over a period of approximately 8 hours. During this time, the sensor retains its ability to detect gas.The calibration interval of electrochemical sensors can be extended when usin … More Information
g SensorAlive. The calibration interval can be determined and adjusted according to application requirements as SensorAlive performs a daily check and issues a warning or error message if there is a deviation.Coupled with the Dräger … More Information
Polytron 8100 transmitter, Dräger SensorAlive provides access to proven measurement technology, permitting usage in Zone 1 / Div 1 rated hazardous atmospheres. Remote sensor installations up to 30 meters (100 feet) away from Polytron 8100 transmitters are supported.The Dräger SensorAlive is also plug-and-play ready thanks to built-in electronic intelligence and pre-calibration.