Dräger X-am® 5000

The Dräger X-am® 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as O2 and harmful concentrations of toxic gases, organic vapors, odorant and amine.

Ergonomic mobile phone design

Despite its advanced functionality, the Dräger X-am 5000’s practical mobile phone design and light-weight make it comfortable to carry. Reduced to its essentials, the two-button control panel and easy-to-follow menu allow for intuitive use.

Flexible sensor exchange

It is easy to exchange, upgrade, or calibrate the sensors to other gases. The ability to customize the Dräger X-am 5000’ssensors makes more applications possible including the possibility to deploy in a rental fleet.

Poison-resistant Ex sensor

For improved safety when facing unknown and potentially explosive hazards—the Dräger X-am 5000 provides dependable warnings in the event of explosive atmospheres due to the high level of sensitivity of the innovative catalytic ex sensor. It not only responds quickly to explosive gases and combustible organic vapors, it is also highly resistant against sensor poisons such as silicone and hydrogen sulfide. In combination with its long-term stability, this offers an extraordinarily long sensor lifetime of over four years. This will reduce operational costs.

Durable sensor technology

Equipped with durable XXS sensor technology, the Dräger X-am 5000 offers maximum security at extremely low operational costs. The sensor’s resistance, in combination with its long-term stability, provides the sensor with a lifetime in excess of four years, which can help reduce operational costs.

Robust and watertight

The Dräger X-am 5000 is water and dust resistant, according to IP67 standards. The detector remains fully functional and ready for use, even after being dropped into water. The integrated rubber protection and shockproof sensors provide additional resistance to impact and vibration. Moreover, the Dräger X-am 5000 is resistant to electromagnetic interference.

External pump

The optional external pump, which operates with a hose length of up to 45 meters (147 feet) long for the Mark II pump, makes it possible to use the detector for pre-entry measurements into confined spaces such as tanks, shafts, etc. The pump starts automatically when attached to the gas detector.

Area monitoring

In combination with the Dräger X-zone® 5500, the gas detector can be used for various area monitoring applications. Up to 25 Dräger X-zone® 5500 units can be automatically interconnected to form a wireless fence line. This interconnection of the area monitoring devices allow for the fast securing of larger areas, e.g. pipelines or industrial tanks—even within the scope of industrial shutdowns.

Optimum solutions for function or bump tests, calibration and documentation

Simple, fast, and professional: from a function or bump test to complete documentation, users can choose from a range of practical, on-site solutions that offer maximum safety for every application. The automatic test and calibration station Dräger X-dock® and the Dräger Bump Test Station are ideal system extensions that save time and reduce workload. Fresh air, mixed gas and single gas calibrations can be done directly using the Dräger X-am 5000 menu.

Flexible power supply

The Dräger X-am 5000 can be used with the standard alkaline batteries. In addition, it can be fitted with a T4 battery that can be charged while still inside the instrument. The optional Save Energy Mode makes it possible to increase the operating time of the Dräger X-am 5000 to more than 40 hours. This is done by selecting a measurement interval of either one second (the standard), 10 or 20 seconds for the CatEx sensor.

360 Product View

Draeger X-am 5000 360

Downloads

X-am 5000 Product Information, en-us
X-am 5000 Product Information, en-us

(Acrobat .PDF) The Dräger X-am® 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to five-gas detector reliably measures combustible gases and vapors as well as O2 and harmful concentrations of toxic gases, organic vapors, odorant and amine.

Download

CC-Vision Basic 8.1.4
CC-Vision Basic 8.1.4

Release Date: 29th October, 2024

Download

Brochure: Dräger sampling hoses for portable gas detectors
Brochure: Dräger sampling hoses for portable gas detectors

Download

Handbook: An Introduction to Gas-Detection Technology (1st Edition)
CC-Vision Software History, en
Collateral: Beware the Toxic Twins CO+HCN (Infographic)
DrägerSensor & Portable Instruments Handbook (6th Edition), en
DrägerSensor and Portable Instruments Handbook, en, version 4
Driver for DIRA and MILO Interface
Gas Detection Solutions Brochure, en-us
GasVision Software History, en
GasVision Version 8.0.6
IFU Bump Test Station - Short instruction - 9033465 bg-me
IFU SP X-am 2500/5000/5600 - Notes on approval / Sensor data - 9033890 en
Quick Guide X-am 2500/5000/5600
Whitepaper - Toxic Twins, en

Gas detectors, sensors and substances

Dräger gas detectors can be used with different sensors to measure a large number of hazardous substances. Check which sensor fits into this detector by searching for a substance. Contact our experts to get more information.

Search for substance

Please enter a substance

Product configurations

for the gas detector Dräger X-am® 5000

Utilise for 79 Substances

32 matching Sensor(s)

Technical Data

Key Facts

Measurable gases
Ex, O2, CO, H2S, NO2, SO2, + (choice out of > 40 sensors)
Sensorports
4
Number of gases
1 - 5
Sensor technology
CAT + EC

Applications

Personal Air Monitoring
Confined Space Entry
Area Monitoring

Technical Data

Operation time
>12h
Dimensions (W × H × D)
1.89x5.12x1.73 "
Weight
7.76 oz
Battery type
NiMh
Degree of protection (IP class)
IP 67

Features

Dual sensors
CatEx Fullrange
D-Light
Internal pump
X-am Pump
X-zone 5500 Area Monitoring
Bump Test Station
X-dock Station
Bluetooth
Bodyguard Alarm (Panic alarm, Motionless detection)
Smart Configuraton in Dräger Gas Detection Connect
Support of Dräger ConHub (Gateway)

Approvals

ATEX
✓ I M1 Ex da ia I Ma, II 1G Ex da ia IIC T4/T3 Ga
IECEx
✓ Ex da ia I Ma, Ex da ia IIC T4/T3 Ga
c CSA us
✓ Class I Div. 1 Group A, B, C, D, E, F, T4/T3 | A/Ex da ia IIC T4/T3 /Ga
CE
GOST (EAC)
✓ PO Ex da ia I Ma X 0Ex da ia IIC T4/T3 Ga X
Performance approval
Shipping approval (MED/DNV GL)