Dräger Simultaneous Test Sets

Tubes
  • Measures five different gases at the same tim
  • Air is simultaneously drawn with Dräger-Tube pump
  • For different combinations of organic and inorganic gases
  • Several different simultaneous test sets available
Dräger Simultaneous Test Sets Tubes
Dräger simultaneous test sets

Reliable safety with the smallest laboratory behind glass

Quick Links
Specifications
Accessories
Downloads
Contact us

Highlights

Risks and potential dangers at a glance: The Simultaneous Test Sets allow the measurement of five different gases at the same time.

Simultaneous measurement

In the Simultaneous Test Sets, five Dräger-Tubes are arranged next to each other in a stable rubber sleeve. The air to be monitored is simultaneously drawn in through the tubes by a Dräger-Tube pump. Quick determinations are made about the presence o More Information

System solution

Each five tube set is comprised of tubes specially calibrated as a system to provide rapid results in the presence of select gases and vapors. Gases and vapors present below the threshold of the first calibration mark may not be indicated.

Fast results

The device delivers fast and reliable results for different combinations of organic and inorganic gases.

Specifications

Dräger VOICE
Your hazmat-based safety product finder

Access relevant information and specific safety equipment recommendations for more than 1,500 hazardous substances.

See the whole Product System.

This product is part of a Dräger system solution. Combine it with the following system components.

Connective Products

CDS Kit
CDS Kit

​The Civil Defense Simultest (CDS) Kit is based on Dräger-Tube simultaneous test sets to check for blood, blister, lung and nerve agents. Each set tests for five chemical agents at once, providing results in under 5 minutes. The kit includes all necessary pumps, tube set adapters and laminated instruction cards in a rugged Pelican case.

CDS-Simultaneous Test Set I
CDS-Simultaneous Test Set I

​Drager-Tubes: S-mustard, phosgene, hydrocyanic acid, lewisite, N-Mustard; measurement time approximately 3 minutes.

CDS-Simultaneous Test Set V
CDS-Simultaneous Test Set V

​Drager-Tubes: cyanogen chloride, S-mustard, phosgene, chlorine, phosphoric acid esters; measurement time approximately 3 minutes.

Pumps for Gas Detection Tubes - Dräger accuro
Dräger accuro
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas
More Information
HazMat Simultest Kit
HazMat Simultest Kit

​The HazMat Simultest Kit is designed to quickly determine the presence or inorganic and organic gases and vapors evolved from a residential or industrial fire, flammable liquids and gases and substances released from a chemical leak / spill.

Simultaneous Test Container Fumigation II
Simultaneous Test Container Fumigation II

​Dräger-Tubes: formaldehyde, phosphine, hydrocyanic acid, methyl bromide, ethylene oxide; measurement approximately 4 minutes.

Simultaneous Test Set Conductive Compounds
Simultaneous Test Set Conductive Compounds

​​Measurement of carbon monoxide, hydrocyanic acid, hydrochloric acid, nitrous gas, formaldehyde; measurement time approximately 2 minutes.

Simultaneous Test Set I for inorganic fumes
Simultaneous Test Set I for inorganic fumes

​Simultaneous Test Set I for inorganic fumes Dräger-Tubes: acid gas, hydrocyanic acid, carbon monoxide, basic gas, nitrous gas; measurement time approximately 40 seconds.

Simultaneous Test Set I Fumigation
Simultaneous Test Set I Fumigation

​Dräger-Tubes: formaldehyde, phosphine, hydrocyanic acid, methyl bromide, ammonia; measurement time approximately 3 minutes.

Simultaneous Test Set II for inorganic fumes
Simultaneous Test Set II for inorganic fumes

​Dräger-Tubes: sulfur dioxide, chlorine, hydrogen sulfide, phosphine, phosgene; measurement time approximately 40 seconds.

Simultaneous Test Set III for organic fumes
Simultaneous Test Set III for organic fumes

​Measurement of ketones, aromatics, alcohols, aliphatic hydrocarbons, chlorinated hydrocarbons; measurement time approximately 40 seconds.

Accessories

Adapter simultaneous test set
Adapter simultaneous test set
The adapter is ordered separately and used with the five tube sets to draw the air through all the tubes simultaneously. A tube scoring tool is included to facilitate removing the ends of the tubes.
Bar probe 400
Bar probe 400


Is used for clearance measurements in containers, e.g. intermodal shipping containers.
Dräger TO 7000
Dräger TO 7000

Using the tube opener Dräger TO 7000, conventional Short-Term Tubes as well as Ampoule and Double Tubes can be opened safety with few jagged edges left behind.

Extension hose simultaneous test
Extension hose simultaneous test

​For use with accuro or X-act 5000 in conjunction with the simultaneous tube sets.

Downloads

Download product information, instructions for use and other important files.
Next Steps

Get in touch with Dräger

smiling woman
Draeger, Inc. – Safety
7256 S. Sam Houston W Pkwy., Suite 100 Houston, TX 77085