This website uses cookies. By using the website you agree to our cookie policy. You can change your cookie settings in your browser.Find out more

2-ChloroacetophenoneC8H7ClO

CAS-No.:
532-27-4
UN-No.:
1697
EC-No.:
208-531-1
Hazard identification number:
60
Warning sign:
  • 60
  • 1697
Hazard signs
GHS05
GHS06
GHS08
Occupational exposure limit
ACGIH (US)
  • TWA (ppm) 0.05
  • TWA (mg/m3) 0.32
NIOSH (REL) (US)
  • TWA (ppm) 0.05
  • TWA (mg/m3) 0.3
NIOSH (US)
  • IDLH (mg/m3) 15
OSHA (PEL) (US)
  • TWA (ppm) 0.05
  • TWA (mg/m3) 0.3
  • H: 300
    Fatal if swallowed.
  • H: 311 + 331
    Toxic in contact with skin.
    Toxic if inhaled.
  • H: 315
    Causes skin irritation
  • H: 318
    Causes serious eye damage.
  • H: 334
    May cause allergy or asthma symptoms or breathing difficulties if inhaled
  • H: 335
    May cause respiratory irritation
  • Melting point:
    138.2 °F
  • Boiling Point:
    476.6 °F
  • Density (at 20 °C, if not notified otherwise):
    1,32 g/cm3
  • Ionization:
    9.6 eV
  • Flash Point:
    244.4 °F
  • Hazardous Effects:
    Ss, Sr
diamond 1 0 4
Details
Diamond-Red1Flammability: Flammable when heated 
Diamond-Yellow0Instability: No danger for normal conditions 
Diamond-Blue4Health: Extremely dangerous 
DG-EA:2Z
Also known as:
  • 2-chloro-1-phenylethanone
  • 2-Chloroacetophenone
  • alpha-Chloroacetophenone
  • Chloromethyl phenyl ketone
  • Phenacyl chloride
  • Phenacylchlorid
  • Phenyl chloromethyl ketone
  • Tear gas

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for 2-Chloroacetophenone C8H7ClO

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Filters

Respirator filter Bayonet

Dräger X-plore® Bayonet Filters

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore ...

Masks

Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • Dräger specific bayonet connection - lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...

Powered Air Purifying Respirators and Filters

​PAPR filters

Dräger X-plore® 8000 Filters

  • ​PAPR filters
  • Particle, gas and combination filters available
  • To be used with powered air-purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odor filter
Powered Air-Purifying Respirator

Dräger X-plore® 8000

  • Powered Air-Purifying Respirator
  • Protection without breathing resistance
  • Different breathing filters and head / face pieces available
  • Protection class IP65
  • For Ex zones 1, 2, 21 and 22

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat