Dimethyl etherC2H6O

CAS-No.:
115-10-6
UN-No.:
1033
EC-No.:
204-065-8
Hazard identification number:
23
Warning sign:
  • 23
  • 1033
Hazard signs
GHS02
GHS04
Occupational exposure limit
WEEL (US)
  • TWA (ppm) 1000
  • H: 220
    Extremely flammable gas.
  • H: 280
    Contains gas under pressure; may explode if heated
  • Melting point:
    -222.7 °F
  • Boiling Point:
    -12.64 °F
  • Density (at 20 °C, if not notified otherwise):
    0,0021146 g/cm3
  • Ionization:
    10.025 ± 0.025 eV
  • Flash Point:
    -43.96 °F
  • Ignition Temperature:
    464 °F
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    5100 hPa
  • Lower Explosive Limit:
    2,8 Vol.-%
  • Upper Explosive Limit:
    24,4 Vol.-%
  •  
diamond 4 0 3
Details
Diamond-Red4Flammability: Easily flammable 
Diamond-Yellow0Instability: No danger for normal conditions 
Diamond-Blue3Health: Very dangerous 
DG-EA:2WE
Also known as:
  • Dimethyl ether
  • DME 99.99
  • GRILLO-one

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for Dimethyl ether C2H6O

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Multi-gas detector

Dräger X-am® 8000

  • Multi-gas detector
  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapors and oxygen

Multi-gas detector

Dräger X-am® 5600 Personal Monitor

  • Multi-gas detector
  • ​1 to 6 gas detection device
  • for personal air monitoring 
  • detection of explosive, flammable and toxic gases as well as vapours and oxygen

Infrared Sensors

Infrared sensors

  • Infrared Sensors
  • ​monitoring of explosive mixtures and CO2
  • recommended for frequent occurrence of explosive gases
  • compatible with: X-am 5600 / 7000 / 8000
  • measuring range: lower explosion limit up to 100 vol.%, for ...

Fixed Gas Detectors and Sensors

Flammable Gas Detectors

Dräger Polytron® 8200 CAT

  • Flammable Gas Detectors
  • ​Sensor: Catalytic bead sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: Display
Flammable Gas Detectors

Dräger Polytron® 5200 CAT

  • Flammable Gas Detectors
  • ​Sensor: Catalytic bead sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: Display
Catalytic bead sensor

Catalytic Bead DrägerSensors®

  • Catalytic bead sensor
  • ​Seamless monitoring of combustible gases and vapors
  • Compatible with: Polytron 8200, Polytron 5200, PointGard 2200, PEX 3000, Polytron SE Ex
  • B121 measuring range: LEL in vol%, ...

Powered Air Purifying Respirators and Filters

​PAPR filters

Dräger X-plore® 8000 Filters

  • ​PAPR filters
  • Particle, gas and combination filters available
  • To be used with powered air-purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odor filter
Powered Air-Purifying Respirator

Dräger X-plore® 8000

  • Powered Air-Purifying Respirator
  • Protection without breathing resistance
  • Different breathing filters and head / face pieces available
  • Protection class IP65
  • For Ex zones 1, 2, 21 and 22

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat