FormaldehydeCH2O

CAS-No.:
50-00-0
UN-No.:
2209
EC-No.:
200-001-8
Hazard identification number:
80
Warning sign:
  • 80
  • 2209
Hazard signs
GHS05
GHS06
GHS08
Occupational exposure limit
ACGIH (US)
  • TWA (ppm) 0.1
  • TWA (mg/m3) 0.12
  • STEL (ppm) 0.3
  • STEL (mg/m3) 0.37
NIOSH (REL) (US)
  • TWA (ppm) 0.016
  • STEL (ppm) C 1 (15min)
NIOSH (US)
  • IDLH (ppm) 20
OSHA (PEL) (US)
  • TWA (mg/m3) 0.75
  • STEL (mg/m3) 2
  • H: 200
    Unstable Explosive.
  • H: 201
    Explosive; mass explosion hazard.
  • H: 301 + 311 + 331
    Toxic if swallowed.
    Toxic in contact with skin.
    Toxic if inhaled.
  • H: 314
    Causes severe skin burns
    and eye damage.
  • H: 317
    May cause an allergic skin reaction
  • H: 335
    May cause respiratory irritation
  • H: 341
    Suspected of causing genetic defects.

  • H: 350
    May cause cancer.
  • H: 370
    Causes damage to organs (or state all
    organs affected, if known) (state route of exposure if it is conclusively proven that no other routes of exposure cause the hazard).
  • Melting point:
    -178.6 °F
  • Boiling Point:
    -2.2 °F
  • Density (at 20 °C, if not notified otherwise):
    0,8153 g/cm3
  • Ionization:
    10.88 ± 0.01 eV
  • Flash Point:
    122 °F - 185 °F
  • Ignition Temperature:
    806 °F
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    4378...4420 (gas); 2 (37% solution) hPa
  • Lower Explosive Limit:
    7 Vol.-%
  • Upper Explosive Limit:
    73 Vol.-%
  • Hazardous Effects:
    C, Ss, M
diamond 4 0 2
Details
Diamond-Red4Flammability: Easily flammable 
Diamond-Yellow0Instability: No danger for normal conditions 
Diamond-Blue2Health: Dangerous 
DG-EA:2YE
Also known as:
  • Carbonyl hydride
  • Formalin
  • Formol
  • HCHO
  • Methanal
  • Methyl aldehyde
  • Methylene glycol
  • Methylene oxide
  • Oxomethane
  • Oxymethylene

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for Formaldehyde CH2O

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Multi-gas detector

Dräger X-am® 8000

  • Multi-gas detector
  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapors and oxygen

Single-gas detector

Dräger Pac® 8000

  • Single-gas detector
  • for personal air monitoring 
  • detection of 29 different gases - including special gases such as nitrogen dioxide, ozone or phosgene
  • non-disposable

Multi-gas detector

Dräger X-am® 5000

  • Multi-gas detector
  • ​1 to 5 gas detection device
  • for personal air monitoring 
  • detection of flammable and toxic gases and organic vapours as well as oxygen and harmful concentrations
Multi-gas detector

Dräger X-am® 5600 Personal Monitor

  • Multi-gas detector
  • ​1 to 6 gas detection device
  • for personal air monitoring 
  • detection of explosive, flammable and toxic gases as well as vapours and oxygen

Electrochemical sensor XS

DrägerSensor® XS

  • Electrochemical sensor XS
  • ​monitoring of toxic gases and oxygen deficiency including hydrides, amines, organic vapours
  • compatible with: X-am 3000 and X-am 7000
  • measuring range: in vol.-% and ...
Electrochemical sensor XXS

DrägerSensor® XXS

  • Electrochemical sensor XXS
  • ​monitoring of toxic gases and lack of oxygen
  • compatible with: Pac series and X-am family
  • measuring range: in vol.-% and ppm

Gas Detection Tubes

Multi-Gas Detector

Dräger X-act® 7000

  • Multi-Gas Detector
  • ​Precise gas measurment in the lower ppb range
  • Based on colorimetric chemical sensor technology
  • All calibration information on the RFID
  • Benzene measurement starting at 1 ppb
  • Ten ...
Short-term tubes

Dräger-Tubes® for short-term measurements

  • Short-term tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Dräger Simultaneous Test Set

Dräger Simultaneous Test Sets

  • Dräger Simultaneous Test Set
  • ​Parallel measurement of five gases
  • Air is simultaneously drawn with Dräger-Tube pump
  • For different combinations of organic and inorganic gases
  • Several different ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • can be used in explosive areas
  • highly visible end of measurement indicator
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Fixed Gas Detectors and Sensors

Toxic Gases and Oxygen Detector

Dräger Polytron® 6100 EC WL

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: Wireless
  • IP class: 66/67 and SIL2
  • Special: Wireless 
Toxic Gases and Oxygen Detector

Dräger Polytron® 8100 EC

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: ...
Toxic Gases and Oxygen Detector

Dräger Polytron® 7000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: 4-20 mA, Bus, HART ®
  • IP class: 66/67 and SIL2
  • Special: Display
Toxic Gases and Oxygen Detector

Dräger PointGard 2100

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Non-explosion proof
  • Interface: 4-20 mA, Relays
  • IP class: IP 66
  • Special: Self-contained gas monitor
Toxic Gases and Oxygen Detector

Dräger Polytron® 5100 EC

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: displays 
Electrochemical gas detector

Electrochemical (EC) DrägerSensor®

  • Electrochemical gas detector
  • ​Continuous monitoring of toxic gases and oxygen
  • Compatible with: Polytron 8100, Polytron 7000, Polytron 6100, Polytron 5100, Polytron 3000, PointGard 2100
  • Measuring ...

Filters

Respirator filter Bayonet

Dräger X-plore® Bayonet Filters

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore ...

Masks

Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • Dräger specific bayonet connection - lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...

Powered Air Purifying Respirators and Filters

​PAPR filters

Dräger X-plore® 8000 Filters

  • ​PAPR filters
  • Particle, gas and combination filters available
  • To be used with powered air-purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odor filter
Powered Air-Purifying Respirator

Dräger X-plore® 8000

  • Powered Air-Purifying Respirator
  • Protection without breathing resistance
  • Different breathing filters and head / face pieces available
  • Protection class IP65
  • For Ex zones 1, 2, 21 and 22

Protective Suits

Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use 

Splash Suit

SPC 4700 with CVA 0700

  • Splash Suit
  • ​Ventilated splash-protective suits
  • Continuous supply of breathing air and cooling airflow (type 3 suit)
  • Coated barrier protection material CPM or carrier fleece material CLF
  • Limited ...

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat