Methyl chlorideCH3Cl

CAS-No.:
74-87-3
UN-No.:
1063
EC-No.:
200-817-4
Hazard identification number:
23
Warning sign:
  • 23
  • 1063
Hazard signs
GHS02
GHS04
GHS08
Occupational exposure limit
ACGIH (US)
  • TWA (ppm) 50
  • TWA (mg/m3) 103
  • STEL (ppm) 100
  • STEL (mg/m3) 207
NIOSH (US)
  • IDLH (ppm) 2000
OSHA (PEL) (US)
  • TWA (ppm) 100
  • STEL (ppm) C 200
  • STEL (ppm) C 300 (5min)
  • H: 220
    Extremely flammable gas.
  • H: 280
    Contains gas under pressure; may explode if heated
  • H: 351
    Suspected of causing cancer.
  • H: 361 f
    Suspected of damaging fertility.
  • H: 373
    May cause damage to organs (state all organs affected, if known) through prolonged or repeated exposure (state route of exposure if it is conclusively
    proven that no other routes of exposure cause the hazard)

  • Melting point:
    -143.32 °F
  • Boiling Point:
    -10.84 °F
  • Density (at 20 °C, if not notified otherwise):
    0,0023065 (0°C) g/cm3
  • Ionization:
    11.26 ± 0.03 eV
  • Ignition Temperature:
    1157 °F
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    4900 hPa
  • Lower Explosive Limit:
    7,6 Vol.-%
  • Upper Explosive Limit:
    19 Vol.-%
  • Hazardous Effects:
    C
  •  
diamond 4 0 2
Details
Diamond-Red4Flammability: Easily flammable 
Diamond-Yellow0Instability: No danger for normal conditions 
Diamond-Blue2Health: Dangerous 
DG-EA:2WE
Also known as:
  • Chloromethane
  • Chloromethane MeCl Methyl Chloride
  • Methyl chloride
  • Monochloromethane

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for Methyl chloride CH3Cl

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Multi-gas detector

Dräger X-am® 8000

  • Multi-gas detector
  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapors and oxygen

Multi-gas detector

Dräger X-am® 5600 Personal Monitor

  • Multi-gas detector
  • ​1 to 6 gas detection device
  • for personal air monitoring 
  • detection of explosive, flammable and toxic gases as well as vapours and oxygen

Infrared Sensors

Infrared sensors

  • Infrared Sensors
  • ​monitoring of explosive mixtures and CO2
  • recommended for frequent occurrence of explosive gases
  • compatible with: X-am 5600 / 7000 / 8000
  • measuring range: lower explosion limit up to 100 vol.%, for ...

Gas Detection Tubes

Sampling tubes

Dräger sampling tubes and systems

  • Sampling tubes
  • ​analysis of the sample in a laboratory
  • measurement of complex compounds and mixtures of substances possible 
  • detection of low concentrations possible 
Short-term tubes

Dräger-Tubes® for short-term measurements

  • Short-term tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • can be used in explosive areas
  • highly visible end of measurement indicator
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Fixed Gas Detectors and Sensors

Flammable Gas Detector

Dräger Polytron® 8700 IR

  • Flammable Gas Detector
  • Sensor: IR Sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: Display
Flammable Gas Detectors

Dräger PointGard 2700

  • Flammable Gas Detectors
  • Sensor: IR Sensor
  • Installation: Non-explosion proof
  • Interface: 4-20 mA, Relays
  • IP class: IP 66
  • Special: Self-contained gas monitor, remotely mounted Dräger PIR 7000
Flammable Gas Detector

Dräger Polytron® 5700 IR

  • Flammable Gas Detector
  • Sensor: IR Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: display

Flammable Gas Detectors

Dräger PIR 7000

  • Flammable Gas Detectors
  • ​Sensor: IR Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA and Bus, HART®
  • IP class: IP66/67 and SIL 2
  • Special: Response Time <1 second

Protective Suits

Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use 

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat