BiphenylC12H10

CAS-No.:
92-52-4
UN-No.:
3077
EC-No.:
202-163-5
Hazard identification number:
90
Warning sign:
  • 90
  • 3077
Hazard signs
GHS07
GHS09
Occupational exposure limit
ACGIH (US)
  • TWA (ppm) 0.2
  • TWA (mg/m3) 1.3
NIOSH (REL) (US)
  • TWA (ppm) 0.2
  • TWA (mg/m3) 1
NIOSH (US)
  • IDLH (mg/m3) 100
OSHA (PEL) (US)
  • TWA (ppm) 0.2
  • TWA (mg/m3) 1
  • H: 315
    Causes skin irritation
  • H: 319
    Causes serious eye irritation
  • H: 335
    May cause respiratory irritation
  • H: 410
    Very toxic to aquatic life with long lasting effects

  • Melting point:
    156.2 °F
  • Boiling Point:
    491 °F
  • Density (at 20 °C, if not notified otherwise):
    1,04 g/cm3
  • Ionization:
    8.16 ± 0.13 eV
  • Flash Point:
    235.4 °F
  • Ignition Temperature:
    1004 °F
  • Lower Explosive Limit:
    0,6 Vol.-%
  • Upper Explosive Limit:
    5,8 Vol.-%
diamond 1 0 2
Details
Diamond-Red1Flammability: Flammable when heated 
Diamond-Yellow0Instability: No danger for normal conditions 
Diamond-Blue2Health: Dangerous 
DG-EA:2X
Also known as:
  • Biphenyl
  • Dibenzol
  • Diphenyl
  • Phenyl benzene
  • Phenylbenzol

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for Biphenyl C12H10

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Gas Detection Tubes

Short-term tubes

Dräger-Tubes® for short-term measurements

  • Short-term tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • can be used in explosive areas
  • highly visible end of measurement indicator
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Filters

Respirator filter Bayonet

Dräger X-plore® Bayonet Filters

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore ...

Masks

Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • Dräger specific bayonet connection - lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...