Vanadium pentoxideV2O5

CAS-No.:
1314-62-1
UN-No.:
2862
EC-No.:
215-239-8
Hazard identification number:
60
Warning sign:
  • 60
  • 2862
Hazard signs
GHS07
GHS08
GHS09
Occupational exposure limit
ACGIH (US)
  • TWA (mg/m3) 0.05 (I)
NIOSH (REL) (US)
  • STEL (mg/m3) C 0.05 (metal)
NIOSH (US)
  • IDLH (none) 35 mg V/m3 dust
  • IDLH (none) 35 mg V/m3 fume
OSHA (PEL) (US)
  • STEL (mg/m3 (resp)) C 0.5
  • STEL (mg/m3) C 0.1 (fume)
  • H: 302 + 332
    Harmful if swallowed or if inhaled
  • H: 318
    Causes serious eye damage.
  • H: 335
    May cause respiratory irritation
  • H: 341
    Suspected of causing genetic defects.

  • H: 361 d
    Suspected of damaging the unborn child.
  • H: 372
    Causes damage to organs (state all organs affected, if known) through prolonged or repeated exposure (state route of exposure if it is conclusively
    proven that no other routes of exposure cause the hazard)

  • H: 411
    Toxic to aquatic life with long lasting
    effects
  • Melting point:
    1274 °F
  • Density (at 20 °C, if not notified otherwise):
    3,35 (25°C) g/cm3
  • Hazardous Effects:
    M, R
  •  
diamond 0 2 3
Details
Diamond-Red0Flammability: No explosion danger 
Diamond-Yellow2Instability: Strong chemical reactions 
Diamond-Blue3Health: Very dangerous 
DG-EA:2X
Also known as:
  • dioxovanadiooxy(dioxo)vanadium Divanadium pentaoxide divanadium pentoxide Divanadiumpentaoxide Divanadium_Pentaoxide London Chemicals & Resources Ltd Vanadium pentaoxide Vanadium Pentoxide
  • Divanadium pentoxide dust
  • Divanadium pentoxide fume
  • Vanadic anhydride dust
  • Vanadic anhydride fume
  • Vanadin(V)-oxide
  • Vanadium dust
  • Vanadium fume
  • Vanadium oxide dust
  • Vanadium oxide fume
  • Vanadium pentaoxide dust
  • Vanadium pentaoxide fume
  • Vanadium pentoxide fused flakes
  • Vanadium(V) oxide

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for Vanadium pentoxide V2O5

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Filters

Respirator filter Rd40

Dräger X-plore® Rd40 Filters

  • Respirator filter Rd40
  • ​standard thread connection Rd40 (40mm)
  • robust aluminium housing
  • to be used with full face masks with standard thread connection Rd40 (40mm)

Respirator filter Bayonet

Dräger X-plore® Bayonet Filters

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore ...

Masks

Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • Dräger specific bayonet connection - lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...
Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40

Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger X-plore® 6570

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • silicone mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...

Powered Air Purifying Respirators and Filters

​PAPR filters

Dräger X-plore® 8000 Filters

  • ​PAPR filters
  • Particle, gas and combination filters available
  • To be used with powered air-purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odor filter
Powered Air-Purifying Respirator

Dräger X-plore® 8000

  • Powered Air-Purifying Respirator
  • Protection without breathing resistance
  • Different breathing filters and head / face pieces available
  • Protection class IP65
  • For Ex zones 1, 2, 21 and 22

Protective Suits

Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use 

Splash Suit

SPC 4700 with CVA 0700

  • Splash Suit
  • ​Ventilated splash-protective suits
  • Continuous supply of breathing air and cooling airflow (type 3 suit)
  • Coated barrier protection material CPM or carrier fleece material CLF
  • Limited ...

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat