Acetic acid butyl esterC6H12O2

Details
CAS-No.:123-86-4
UN-No.:1123
EC-No.:204-658-1
Hazard identification number:30
Warning sign
  • 30
  • 1123
Hazard signs
GHS02
GHS07
Occupational exposure limit
  • TWA (ppm) 50
  • TWA (mg/m3) 238
  • STEL (ppm) 150
  • STEL (mg/m3) 712
  • H: 226
    Flammable liquid and vapour
  • H: 336
    May cause drowsiness or dizziness
Melting point:-106.6 °F
Boiling Point:260.6 °F
Density (at 20 °C, if not notified otherwise):0,88 g/cm3
Ionization:9.92 ± 0.05 eV
Flash Point:80.6 °F
Ignition Temperature:734 °F
Vapour Pressure (at 20 °C, if not notified otherwise):10,7 hPa
Lower Explosive Limit:1,2 Vol.-%
Upper Explosive Limit:8,5 Vol.-%
diamond30 1

Details

Diamond-Red3Flammability: Flammable with normal temperature 
Diamond-Yellow0Instability: No danger for normal conditions 
Diamond-Blue1Health: Low risk. Filter recommended 
DG-EA:3Y
Also known as:
  • 1-Butyl acetate
  • Acetic acid n-butyl ester
  • Acetic acid, butyl ester (8CI, 9CI)
  • Butyl acetate
  • Butyl ethanoate
  • MFA-75B
  • MHG-80B
  • n-Butyl acetate
  • n-Butyl ester of acetic acid
  • TKA-90SB

Suitable products for Acetic acid butyl ester C6H12O2

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Multi-gas detector

Dräger X-am® 8000

  • Multi-gas detector
  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapors and oxygen

Multi-gas detector

Dräger X-am® 3500

  • Multi-gas detector
  • ​1 to 4 gas detection device
  • for clearance measurement
  • detection of flammable gases and vapours as well as O2, CO, H2S, NO2 and SO2
Multi-gas detector

Dräger X-am® 5000

  • Multi-gas detector
  • ​1 to 5 gas detection device
  • for personal air monitoring 
  • detection of flammable and toxic gases and organic vapours as well as oxygen and harmful concentrations
Multi-gas detector

Dräger X-am® 2500

  • Multi-gas detector
  • ​1 to 4 gas detection device
  • for personal air monitoring 
  • detection of flammable gases and vapours as well as O2, CO, NO2, SO2 and H2S
Multi-gas detector

Dräger X-am® 5600 Personal Monitor

  • Multi-gas detector
  • ​1 to 6 gas detection device
  • for personal air monitoring 
  • detection of explosive, flammable and toxic gases as well as vapours and oxygen

Multigas detector

Dräger X-pid® 9500

  • Multigas detector
  • ​​Selective VOC gas detection
  • For frequent testing of toxic & carcinogenic substances
  • Laboratory quality results in very low concentrations
  • Benzene measurement starting from 50 ...
Infrared Sensors

Infrared sensors

  • Infrared Sensors
  • ​monitoring of explosive mixtures and CO2
  • recommended for frequent occurrence of explosive gases
  • compatible with: X-am 5600 / 7000 / 8000
  • measuring range: lower explosion limit up to 100 vol.%, for ...
null

PID sensors

Catalytic Ex-Sonsors

Dräger Catalytic Ex-Sensors

  • Catalytic Ex-Sonsors
  • ​monitoring of explosive mixtures
  • high poisoning resistance to silicones and H2S
  • compatible with: X-am family
  • measuring range: lower explosion limit up to 100 vol.-%

Gas Detection Tubes

Sampling tubes

Dräger sampling tubes and systems

  • Sampling tubes
  • ​analysis of the sample in a laboratory
  • measurement of complex compounds and mixtures of substances possible 
  • detection of low concentrations possible 
Short-term tubes

Dräger-Tubes® for short-term measurements

  • Short-term tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • can be used in explosive areas
  • highly visible end of measurement indicator
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Fixed Gas Detectors and Sensors

Flammable Gas Detectors

Dräger Polytron® 8200 CAT

  • Flammable Gas Detectors
  • ​Sensor: Catalytic bead sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: Display
Flammable Gas Detectors

Dräger Polytron® 5200 CAT

  • Flammable Gas Detectors
  • ​Sensor: Catalytic bead sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: Display
null

Catalytic Bead DrägerSensors®

Powered Air Purifying Respirators and Filters

​PAPR filters

Dräger X-plore® 8000 Filters

  • ​PAPR filters
  • Particle, gas and combination filters available
  • To be used with powered air-purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odor filter
Powered Air-Purifying Respirator

Dräger X-plore® 8000

  • Powered Air-Purifying Respirator
  • Protection without breathing resistance
  • Different breathing filters and head / face pieces available
  • Protection class IP65
  • For Ex zones 1, 2, 21 and 22

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat