Dräger M2000

Full Face Masks
  • Dedicated full-face mask for defense forces
  • Protection against biological and chemical warfare agents, and particles of radioactive substances
  • Available in various sizes
Side view of Dräger M2000

Ensuring critical protection for CBRN operations and civil defense.

Quick Links
Specifications
Accessories
Downloads
Contact us

Highlights

The M2000 full face respirator has been specifically designed to meet the demanding requirements of military and security operations. In combination with a suitable filter, it offers enhanced protection against biological and chemical warfare agents, as well as against particulate radioactive substances.

Effective protection

Two filter options are available for the M2000 full face mask: NATO-standard round-threaded filters for use with existing filter stocks, or the special Dräger F2000 plug-in filter. Both filter options offer reliable protection against biological and  More information

Dräger M2000 Full Face Masks -

Optimal wearing comfort - even during prolonged operations

The M2000 offers a high level of comfort for operational personnel, even during prolonged operations lasting over 24 hours. The optimised air circulation effectively prevents the mask’s visor and even eyeglasses from fogging up. An integrated hole in More information

Dräger M2000 Full Face Masks -

Optimal fit​ and rapid operational readiness

The M2000 mask body is available in three different sizes (S, M, L) and the inner mask in two sizes (S, M/L). This ensures a secure and reliable seal for a wide variety of face shapes and contours. The 6-point harness system allows the respirator to  More information

Dräger M2000 Full Face Masks -

Highest compatibility

The M2000 full face mask is compatible with all standard helmets and overgarments used in the defence sector. The integrated speech diaphragm enables clear and reliable communication – including via radio – even in demanding operational environments. More information

Dräger M2000 Full Face Masks -

Easy to maintain

No special tools are required for the maintenance and repair of the M2000, which makes servicing considerably easier. Thanks to the large number of common parts across all three sizes, spare parts costs and logistics are significantly reduced.

360° Product View

Draeger M2000 360

See the whole Product System.

This product is part of a Dräger system solution. Combine it with the following system components.

Connective Products

Tubes - Dräger Civil Defense Set
Dräger Civil Defense Set
  • Specialized set for detecting up to five different chemical agents simultaneously in just five minutes
  • Easy handling, cost-effective, and requires minimal training
  • No calibration needed
More Information
Hazmat Suits - Dräger CPS 7800 olive
Dräger CPS 7800 olive
  • Reusable, gas-tight suit
  • Protection against a wide range of gaseous, liquid, aerosol and solid hazardous and warfare agents, even in areas of explosion hazard
  • SCBA worn over the protective suit
More Information
Hazmat Suits - Dräger CPS 7900 olive, beige
Dräger CPS 7900 olive, beige
  • Reusable gas-tight suit for use in CBRN hazard situations
  • Protection against industrial chemicals, biological agents, and others
  • Suitable for civil emergency and disaster recovery missions, and decontamination work
More Information
Respiratory Filters - Dräger NBC and civil defence filters
Dräger NBC and civil defence filters
  • Special filters offering civil defence and protection against a variety of hazardous chemicals
  • With standard thread connection Rd40
More Information
Dräger Plug-in filter F2000
Dräger Plug-in filter F2000
The Dräger F2000 is a plug-in filter that allows for quick filter changes and can be positioned to the right or left. The filter provides reliable protection against biological and chemical warfare agents, as well as particulate radioactive substances.
Respiratory Protection Test Equipment - Dräger Quaestor 8000
Dräger Quaestor 8000
  • Performs fully automatic static and dynamic tests
  • Tests full-face masks, chemical protection suits, and compressed air breathing apparatus (others possible, if required) for functionality and leak tightness"
More Information

Accessories

CamelBak adapter for the Dräger M2000
CamelBak adapter for the Dräger M2000
For connecting a CamelBak hydration system to the mask.
Respiratory Filters - Dräger X-plore® Rd40
Dräger X-plore® Rd40
  • Filter series with standard thread connection Rd40 according to EN 148-1
  • Robust aluminium housing with long life time
  • Suitable for use with Rd40 threaded half and full face masks
More Information
Hose adapter for the Dräger M2000
Hose adapter for the Dräger M2000
For connection of the mask to a drinking canteen.
Spectacle frame for the Dräger M2000
Spectacle frame for the Dräger M2000
Spectacle frame, can be individually adjusted right and left.

Downloads

Download product information, instructions for use and other important files.
Next Steps

Get in touch with Dräger

Smiling woman with blonde hair
Draeger Australia Pty. Ltd.
​8 Acacia Place Notting Hill Victoria 3168
Draeger New Zealand Ltd.
​Unit 4 24 Bishop Dunn Place East Tamaki Auckland 2013