Dräger Oxylog® 3000 plus Emergency and Transport Ventilators

Dräger Oxylog® 3000 plus

Contact us

Dräger Oxylog® 3000 plus

Offering high ventilation performance with features such as AutoFlow® integrated capnography and non-invasive Ventilation, the compact and robust Oxylog® 3000 plus helps you transport your patients safely and provides feedback on correctness of intubation and ventilation effectiveness. The Oxylog® 3000 plus gives you confidence to master even demanding situations.

High confidence during transport

Whether you are transporting critically ill patients in your hospital or in the field, with new features such as AutoFlow®, integrated capnography, full paediatric support and enhanced data connectivity, you don't have to compromise on therapy during transport. ​

Wide range of ventilation modes and AutoFlow

The Oxylog 3000 plus offers a complete range of volume- and pressure controlled ventilation modes, including VC-AC, VC-SIMV, Spn-CPAP and PC-BIPAP*. Non-invasive ventilation with leak compensation is also provided as standard. With the AutoFlow option, you can provide volume controlled ventilation with minimised peak inspiratory pressure for advanced patient care.

Integrated capnography

Monitoring patients in the field can be challenging. Available with integrated mainstream CO2 monitoring, the Oxylog 3000 plus helps you confirm correct intubation and ventilation performance at all times. ​

Ready for paediatric patients

A specially designed, dedicated paediatric patient circuit with reduced dead space and low compliance is available for use with the Oxylog 3000 plus. This enables you to provide quality ventilation to an even wider range of patients with a single device.

Automatic altitude compensation

Tested for use in fixed and rotary wing aircraft, the Oxylog 3000 plus automatically compensates for altitude, adjusting provided- and measured patient volumes accordingly, eliminating the need for manual calculation and reducing the risk of error.

Standard equipment

The Oxylog 3000 plus uses the same reusable and disposable hoses like Oxylog 3000 and Oxylog 2000 plus. This increases your efficiency and saves you valuable storage space and training time.

Intuitive user interface

The Oxylog 3000 plus uses the same intuitive user interface common to most current Dräger products. The select-adjust-confirm operating system facilitates a rapid user familiarization process. Clinical parameters, curves and ventilation settings are clearly displayed on the screen which makes sure you can have a quick assessment of the patient’s status even in hectic situations. The intuitive user interface allows you to easily and quickly operate the device after switching it on.

Advanced data export functionality

With its advanced data export functions, the Oxylog 3000 plus can not only export ventilation parameter data to external monitors and data management systems in real time, but it can also take full advantage of Dräger Remote Service. This concept lets you transfer status information from your Oxylog 3000 plus to DrägerService for analysis. This supports you in increasing equipment up-time.

* Trademark used under license ​

360 Product View

Draeger Oxylog 3000 plus 360

Downloads

Alduk IV Product information, en
Alduk IV Product information, en

Thanks to its compact and robust design as well as its excellent performance, the Alduk IV is user-friendly in its handling for use in hospitals, rescue service deployments and also for overland and air transport.

Download

BTPS & Ambient Pressure Correction in air medical transport
BTPS & Ambient Pressure Correction in air medical transport

Mechanical ventilation can be challenging during air medical transport, particularly due to the impact of changing atmospheric pressure with changing altitude.

Download

Oxylog 3000 plus Product Information, en
Oxylog 3000 plus Product Information, en

Download

Oxylog Carrying System Product information, en
Oxylog Trolley Product Information, en
Oxylog 3000 plus Brochure, en
Special print: Rettungs-Magazin (PDF)
Booklet: It began with the Pulmotor One Hundred Years of Artificial Ventilation (PDF)
Neonatal and pediatric accessories catalogue, en
Special Print: Der Notarzt
Accessory Catalogue 2025/2026, en
AutoFlow® Booklet, en
Nomenclature Booklet, en
Breathing Booklet, en
AutoFlow Booklet, en
NIV Booklet, en
CO2-measurement during ventilation, Booklet, en
NIV Booklet Oxylog 2000 plus/3000 plus, en
Mini Manual Ventilation, en
Oxylog & More Catalogue, en

Technical Data

Protective Ventilation

Operational Application
Inter- and intra-clinical transport ventilator, ICU ventilation standard at all time
Patient categories
Adults, pediatric patients
Ventilator technology
DuroFlow blower
Inspiratory Flow
max. 100 L/min

Ventilation Modes

Volume controlled ventilation
Pressure controlled ventilation (PC-BIPAP/SIMV)
Support of spontaneous breathing

Technical Data

Screen Display
108x56 mm EL
Serial interfaces
RS232
Internal Battery
9.5 hours

Features

AutoFlow®
Volume Guarantee
Non-invasive ventilation
CO2-Monitoring
O2-therapy