This website uses cookies. By using the website you agree to our cookie policy. You can change your cookie settings in your browser.Find out more

3-Chloro-1-propeneC3H5Cl

CAS-No.:
107-05-1
UN-No.:
1100
EC-No.:
203-457-6
Hazard identification number:
336
Warning sign:
  • 336
  • 1100
Hazard signs
GHS02
GHS06
GHS07
GHS08
GHS09
Occupational exposure limit
WORKPLACE EXPOSURE STANDARDS FOR AIRBORNE CONTAMINANTS (AU)
  • TWA (ppm) 1
  • STEL (ppm) 2
  • TWA (mg/m3) 3
  • STEL (mg/m3) 6
  • H: 225
    Highly flammable liquid and vapour
  • H: 301
    Toxic if swallowed
  • H: 311
    Toxic in contact with skin
  • H: 315
    Causes skin irritation
  • H: 319
    Causes serious eye irritation
  • H: 331
    Toxic if inhaled
  • H: 335
    May cause respiratory irritation
  • H: 341
    Suspected of causing genetic defects. 
  • H: 351
    Suspected of causing cancer.
  • H: 372
    Causes damage to organs (state all organs affected, if known) through prolonged or repeated exposure (state route of exposure if it is conclusively
    proven that no other routes of exposure cause the hazard)
  • H: 400
    Very toxic to aquatic life
  • Melting point:
    -136 °C
  • Boiling Point:
    45 °C
  • Density (at 20 °C, if not notified otherwise):
    0,94 g/cm3
  • Ionization:
    10.05 ± 0.01 eV
  • Flash Point:
    -32 °C
  • Ignition Temperature:
    390 °C
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    398 hPa
  • Lower Explosive Limit:
    3,26 Vol.-%
  • Upper Explosive Limit:
    11,2 Vol.-%
  • Hazardous Effects:
    C,M
diamond 3 1 4
Details
Diamond-Red3Flammability: Flammable with normal temperature 
Diamond-Yellow1Instability: Instable when heated 
Diamond-Blue4Health: Extremely dangerous 
DG-EA:3WE
Also known as:
  • 1-Chloro-2-propene
  • 3-chloroprop-1-ene
  • 3-Chloropropene
  • 3-Chloropropylene
  • Allyl chloride
  • Allylchloride

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for 3-Chloro-1-propene C3H5Cl

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Multi-gas detector

Dräger X-am® 8000

  • Multi-gas detector
  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapours and oxygen
PID sensor

PID sensors

  • PID sensor
  • ​detection of volatile organic compounds in low concentrations
  • compatible with: X-am 7000 and X-am 8000 – selective benzene measurement with pre-tubes possible
  • measuring range: in ppm ...

Gas Detection Tubes

Short-term Tubes

Dräger Short-term Tubes

  • Short-term Tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • display for clear readability of results
  • can be used in explosive areas
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Fixed Gas Detection and Sensors

Flammable Gas Detector

Dräger Polytron® 8700 IR

  • Flammable Gas Detector
  • Sensor: IR Sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: Display
Flammable Gas Detector

Dräger Polytron® 5700 IR

  • Flammable Gas Detector
  • Sensor: IR Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: display

Flammable Gas Detectors

Dräger PointGard 2700

  • Flammable Gas Detectors
  • Sensor: IR Sensor
  • Installation: Non-explosion proof
  • Interface: 4-20 mA, Relays
  • IP class: IP 66
  • Special: Self-contained gas monitor, remotely mounted Dräger PIR 7000
Flammable Gas Detectors

Dräger PIR 7000

  • Flammable Gas Detectors
  • ​Sensor: IR Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA and Bus, HART®
  • IP class: IP66/67 and SIL 2
  • Special: Response Time <1 second

Filters

Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...

Masks and Filters

Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40

Protective Suits

Gas-tight suit

Dräger CPS 5800

  • Gas-tight suit
  • SCBA worn over the protective suit
  • four suit sizes (M-XXL)
  • diagonal zipper for donning without assistance
  • suit material Zytron® 500, limited use

Gas-tight suit

Dräger CPS 7900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit 
  • five suit sizes (S-XXL)
  • side zipper
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 7800

  • Gas-tight suit
  • ​SCBA worn over the protective suit 
  • five suit sizes (S-XXL)
  • diagonal zipper for easy donning and doffing without assistance
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat