Acetic acid, pentyl esterC7H14O2

CAS-No.:
628-63-7
UN-No.:
1104
EC-No.:
211-047-3
Hazard identification number:
30
Warning sign:
  • 30
  • 1104
Hazard signs
GHS02
Occupational exposure limit
WORKPLACE EXPOSURE STANDARDS FOR AIRBORNE CONTAMINANTS (AU)
  • TWA (ppm) 50
  • STEL (ppm) 100
  • TWA (mg/m3) 270
  • STEL (mg/m3) 541
  • H: 226
    Flammable liquid and vapour
  • Melting point:
    -71 °C
  • Boiling Point:
    149 °C
  • Density (at 20 °C, if not notified otherwise):
    0,88 g/cm3
  • Flash Point:
    41 °C
  • Ignition Temperature:
    350 °C
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    5,3 hPa
  • Lower Explosive Limit:
    1 Vol.-%
  • Upper Explosive Limit:
    7,5 Vol.-%
diamond 3 0 1
Details
Diamond-Red3Flammability: Flammable with normal temperature 
Diamond-Yellow0Instability: No danger for normal conditions 
Diamond-Blue1Health: Low risk. Filter recommended 
DG-EA:3Y
Also known as:
  • 1-Pentanol acetate
  • Amyl acetic ester
  • Amylacetat
  • n-Amyl acetate
  • n-Pentylacetat
  • pentyl acetate
  • Pentyl ester of acetic acid
  • Primary amyl acetate

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for Acetic acid, pentyl ester C7H14O2

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Gas Detection Tubes

Short-term Tubes

Dräger Short-term Tubes

  • Short-term Tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
null

Dräger Sampling Tubes and Systems

Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • display for clear readability of results
  • can be used in explosive areas
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Filters

Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...
Respirator filter Rd90

Dräger X-plore® Rd90 Filters

  • Respirator filter Rd90
  • ​Dräger specific Rd90 connection
  • robust aluminium housing
  • to be used in combination with X-plore 4700 half masks
Respirator filter Bayonet

Dräger X-plore® Bayonet

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore 3500 ...

Masks and Filters

Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40
Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • ​Dräger specific bayonet connection – lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...

Powered Air Purifying Respirator

Filters for PAPR

Dräger X-plore® 8000 Filters

  • Filters for PAPR
  • Particle, gas and combination filters available
  • To be used with powered air purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odour filter

null

Dräger X-plore® 8000

Protective Suits

Gas-tight suit

Dräger CPS 7900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit 
  • five suit sizes (S-XXL)
  • side zipper
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 7800

  • Gas-tight suit
  • ​SCBA worn over the protective suit 
  • five suit sizes (S-XXL)
  • diagonal zipper for easy donning and doffing without assistance
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 6900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit 
  • five suit sizes (S-XXL)
  • side zipper for donning without assistance 
  • suit material Umex, reusable
Gas-tight suit

Dräger CPS 6800

  • Gas-tight suit
  • SCBA worn over the protective suit
  • five suit sizes (S-XXL)
  • diagonal zipper for donning without assistance 
  • suit material Umex, reusable

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat