2-Propenoic acid ethyl esterC5H8O2

CAS-No.:
140-88-5
UN-No.:
1917
EC-No.:
205-438-8
Hazard identification number:
339
Warning sign:
  • 339
  • 1917
Hazard signs
GHS02
GHS06
GHS07
Occupational exposure limit
WORKPLACE EXPOSURE STANDARDS FOR AIRBORNE CONTAMINANTS (AU)
  • TWA (mg/m3) 20 Peak limitation
  • TWA (ppm) 5 Peak limitation
  • H: 225
    Highly flammable liquid and vapour
  • H: 302
    Harmful if swallowed
  • H: 312
    Harmful in contact with skin.
  • H: 315
    Causes skin irritation
  • H: 317
    May cause an allergic skin reaction
  • H: 319
    Causes serious eye irritation
  • H: 331
    Toxic if inhaled
  • H: 335
    May cause respiratory irritation
  • H: 412
    Harmful to aquatic life with long lasting effects
  • Melting point:
    < -75 °C
  • Boiling Point:
    100 °C
  • Density (at 20 °C, if not notified otherwise):
    0,92 g/cm3
  • Ionization:
    ≤10.3 eV
  • Flash Point:
    9 °C
  • Ignition Temperature:
    350 °C
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    39,1 hPa
  • Lower Explosive Limit:
    1,7 Vol.-%
  • Upper Explosive Limit:
    13 Vol.-%
  • Hazardous Effects:
    Ss
diamond 3 4 3
Details
Diamond-Red3Flammability: Flammable with normal temperature 
Diamond-Yellow4Instability: High explosion danger 
Diamond-Blue3Health: Very dangerous 
DG-EA:3WE
Also known as:
  • 2-Propenoic Acid Ethyl Ester
  • Acrylate déthyle
  • Acrylic acid ethyl ester (6CI, 8CI)
  • CH2-CHCOOC2H5
  • CH2CHCOOC2H5
  • EA
  • Ethoxycarbonylethylene
  • Ethyl 2-propenoate
  • Ethyl acrylate
  • Ethyl acrylate (inhibited)
  • Ethyl Acrylate Monomer
  • Ethyl ester of acrylic acid
  • Ethyl propenoate
  • ethylacrylate
  • Norsocryl AE

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for 2-Propenoic acid ethyl ester C5H8O2

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Multi-gas detector

Dräger X-am® 5600

  • Multi-gas detector
  • ​1 to 6 gas detection device
  • for personal air monitoring 
  • detection of explosive, flammable and toxic gases as well as vapours and oxygen
Multi-gas detector

Dräger X-am® 8000

  • Multi-gas detector
  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapours and oxygen
Multigas detector

Dräger X-pid® 9500

  • Multigas detector
  • ​Selective VOC gas detection
  • For frequent testing of toxic & carcinogenic substances
  • Laboratory quality results in very low concentrations
  • Benzene measurement starting from 50 ...
Infrared Sensors

Dräger Infrared Sensors

  • Infrared Sensors
  • ​monitoring of explosive mixtures and CO2
  • recommended for frequent occurrence of explosive gases
  • compatible with: X-am 5600 / 7000 / 8000
  • measuring range: lower explosion limit up to 100 vol.%, for ...

Gas Detection Tubes

Short-term Tubes

Dräger Short-term Tubes

  • Short-term Tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
null

Dräger Sampling Tubes and Systems

Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • display for clear readability of results
  • can be used in explosive areas
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Filters

Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...
Respirator filter Rd90

Dräger X-plore® Rd90 Filters

  • Respirator filter Rd90
  • ​Dräger specific Rd90 connection
  • robust aluminium housing
  • to be used in combination with X-plore 4700 half masks
Respirator filter Bayonet

Dräger X-plore® Bayonet

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore 3500 ...

Masks and Filters

Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40
Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • ​Dräger specific bayonet connection – lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...

Powered Air Purifying Respirator

Filters for PAPR

Dräger X-plore® 8000 Filters

  • Filters for PAPR
  • Particle, gas and combination filters available
  • To be used with powered air purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odour filter

null

Dräger X-plore® 8000

Protective Suits

Gas-tight suit

Dräger CPS 5800

  • Gas-tight suit
  • SCBA worn over the protective suit
  • four suit sizes (M-XXL)
  • diagonal zipper for donning without assistance
  • suit material Zytron® 500, limited use

Gas-tight suit

Dräger CPS 7900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit 
  • five suit sizes (S-XXL)
  • side zipper
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 7800

  • Gas-tight suit
  • ​SCBA worn over the protective suit 
  • five suit sizes (S-XXL)
  • diagonal zipper for easy donning and doffing without assistance
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat