This website uses cookies. By using the website you agree to our cookie policy. You can change your cookie settings in your browser.Find out more

1,3-ButadieneC4H6

CAS-No.:
106-99-0
UN-No.:
1010
EC-No.:
203-450-8
Hazard identification number:
239
Warning sign:
  • 239
  • 1010
Hazard signs
GHS02
GHS04
GHS08
Occupational exposure limit
WORKPLACE EXPOSURE STANDARDS FOR AIRBORNE CONTAMINANTS (AU)
  • TWA (ppm) 10
  • TWA (mg/m3) 22
  • H: 220
    Extremely flammable gas
  • H: 280
    Contains gas under pressure; may explode if heated
  • H: 340
    May cause genetic defects (state route of exposure if it is conclusively proven that no other routes of exposure cause
    the hazard)
  • H: 350
    May cause cancer.
  • Melting point:
    -108.9 °C
  • Boiling Point:
    -4.5 °C
  • Density (at 20 °C, if not notified otherwise):
    0,0024982 (0°C) g/cm3
  • Ionization:
    9.072 ± 0.007 eV
  • Flash Point:
    -85 °C
  • Ignition Temperature:
    415 °C
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    2400 (20°C) hPa
  • Lower Explosive Limit:
    1,4 Vol.-%
  • Upper Explosive Limit:
    16,3 Vol.-%
  • Hazardous Effects:
    C, M
Important to know:
Substance included in the Community Rolling Action Plan (CoRAP).
Also known as:
  • .alpha.,.gamma.-Butadiene
  • 1,3 -BD
  • Biethylene
  • Bivinyl
  • Buta-1,3-diene
  • Butadiene
  • CH-CH
  • CH2
  • Divinyl
  • Erythrene
  • H2C
  • H2C=CH-CH=CH2
  • Pyrrolylen
  • Vinylethylene

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for 1,3-Butadiene C4H6

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Multi-gas detector

Dräger X-am® 5600

  • Multi-gas detector
  • ​1 to 6 gas detection device
  • for personal air monitoring 
  • detection of explosive, flammable and toxic gases as well as vapours and oxygen
Single-gas detector

Dräger Pac® 8000

  • Single-gas detector
  • ​for personal air monitoring 
  • detection of 29 different gases – including special gases such as nitrogen dioxide, ozone or phosgene
  • non-disposable
Multi-gas detector

Dräger X-am® 8000

  • Multi-gas detector
  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapours and oxygen
Multi-gas detector

Dräger X-am® 5000

  • Multi-gas detector
  • ​1 to 5 gas detection device
  • for personal air monitoring 
  • detection of flammable and toxic gases and organic vapours as well as oxygen and harmful concentrations

Dräger X-am® 5800

Multi-gas detector

Dräger X-am® 2500

  • Multi-gas detector
  • ​1 to 4 gas detection device
  • for personal air monitoring 
  • detection of flammable gases and vapours as well as O2, CO, NO2, SO2 and H2S
Multi-gas detector

Dräger X-am® 3500

  • Multi-gas detector
  • ​1 to 4 gas detection device
  • for clearance measurement
  • detection of flammable gases and vapours as well as O2, CO, H2S, NO2 and SO2
Multigas detector

Dräger X-pid® 9500

  • Multigas detector
  • ​Selective VOC gas detection
  • For frequent testing of toxic & carcinogenic substances
  • Laboratory quality results in very low concentrations
  • Benzene measurement starting from 50 ...
Electrochemical sensor XXS

DrägerSensor XXS

  • Electrochemical sensor XXS
  • ​monitoring of toxic gases and lack of oxygen
  • compatible with: Pac series and X-am family
  • measuring range: in vol.-% and ppm
Infrared Sensors

Dräger Infrared Sensors

  • Infrared Sensors
  • ​monitoring of explosive mixtures and CO2
  • recommended for frequent occurrence of explosive gases
  • compatible with: X-am 5600 / 7000 / 8000
  • measuring range: lower explosion limit up to 100 vol.%, for ...
Electrochemical sensor XS

DrägerSensor XS

  • Electrochemical sensor XS
  • ​monitoring of toxic gases and oxygen deficiency including hydrides, amines, organic vapours
  • compatible with: X-am 3000 and X-am 7000
  • measuring range: in vol.-% and ...
Catalytic Ex-Sensors

Dräger Catalytic Ex-Sensors

  • Catalytic Ex-Sensors
  • ​monitoring of explosive mixtures
  • high poisoning resistance to silicones and H2S
  • compatible with: X-am family
  • measuring range: lower explosion limit up to 100 vol.-%
PID sensor

PID sensors

  • PID sensor
  • ​detection of volatile organic compounds in low concentrations
  • compatible with: X-am 7000 and X-am 8000 – selective benzene measurement with pre-tubes possible
  • measuring range: in ppm ...

Gas Detection Tubes

Short-term Tubes

Dräger Short-term Tubes

  • Short-term Tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
null

Dräger Sampling Tubes and Systems

Multi-Gas Detector

Dräger X-act® 7000

  • Multi-Gas Detector
  • ​Opto-electronic analysis system for selective detection of carcinogenic and toxic substances
  • Lab quality measurement in ppb range
  • To be used with Dräger MicroTubes
  • With coupler ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • display for clear readability of results
  • can be used in explosive areas
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Fixed Gas Detection and Sensors

Flammable Gas Detectors

Dräger Polytron® SE Ex

  • Flammable Gas Detectors
  • Sensor: Catalytic bead sensor
  • Installation: Increased Safety
  • Interface: 3-wire cable
  • IP class: IP 66
  • Special: Sensing Head
Flammable Gas Detectors

Dräger PEX 3000

  • Flammable Gas Detectors
  • ​Sensor: Catalytic Bead Sensor
  • Installation: with Increased Safety 
  • Interface: 4-20 mA
  • IP class: IP66
  • Special: -
Flammable Gas Detectors

Dräger Polytron® 5200 CAT

  • Flammable Gas Detectors
  • ​Sensor: Catalytic bead sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: Display
Flammable Gas Detectors

Dräger Polytron® 8200 CAT

  • Flammable Gas Detectors
  • ​Sensor: Catalytic bead sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: Display
Toxic Gases and Oxygen Detector

Dräger Polytron® 8100 EC

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: ...
Toxic Gases and Oxygen Detector

Dräger Polytron® 5100 EC

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: displays 
Toxic Gases and Oxygen Detector

Dräger Polytron® 6100 EC WL

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: Wireless
  • IP class: 66/67 and SIL2
  • Special: Wireless 
Toxic Gases and Oxygen Detector

Dräger Polytron® 7000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: 4-20 mA, Bus, HART ®
  • IP class: 66/67 and SIL2
  • Special: Display
Toxic Gases and Oxygen Detector

Dräger PointGard 2100

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Non-explosion proof
  • Interface: 4-20 mA, Relays
  • IP class: IP 66
  • Special: Self-contained gas monitor
Electrochemical Gas Detector

Electrochemical DrägerSensor®

  • Electrochemical Gas Detector
  • ​continuous monitoring of poisonous gases and oxygen
  • compatible with: Polytron 8100, Polytron 7000, Polytron 6100, Polytron 5100, Polytron 3000, PointGard ...
Catalytic bead sensor

Catalytic Bead DrägerSensor®

  • Catalytic bead sensor
  • ​Seamless monitoring of combustible gases and vapours
  • Compatible with: Polytron 8200, Polytron 5200, PointGard 2200, PEX 3000, Polytron SE Ex
  • B121 measuring range: LEL in ...

Filters

Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...

Masks and Filters

Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40

Protective Suits

Gas-tight suit

Dräger CPS 5800

  • Gas-tight suit
  • SCBA worn over the protective suit
  • four suit sizes (M-XXL)
  • diagonal zipper for donning without assistance
  • suit material Zytron® 500, limited use

Gas-tight suit

Dräger CPS 7900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit 
  • five suit sizes (S-XXL)
  • side zipper
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 7800

  • Gas-tight suit
  • ​SCBA worn over the protective suit 
  • five suit sizes (S-XXL)
  • diagonal zipper for easy donning and doffing without assistance
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat