Carbon disulfideCS2
CAS-No.: | 75-15-0 |
---|---|
UN-No.: | 1131 |
EC-No.: | 200-843-6 |
Hazard identification number: | 336 |
Warning sign: |
|
Hazard signs
Occupational exposure limit
ACGIH (US)
- TWA (ppm) 1
- TWA (mg/m3) 3.13
NIOSH (REL) (US)
- TWA (ppm) 1
- TWA (mg/m3) 3
- STEL (ppm) 10
- STEL (mg/m3) 30
NIOSH (US)
- IDLH (ppm) 500
OSHA (PEL) (US)
- TWA (ppm) 20
- STEL (ppm) C 30
- STEL (ppm) 100 (30min)
- H: 225
Highly flammable liquid and vapour
- H: 315
Causes skin irritation
- H: 319
Causes serious eye irritation
- H: 372
Causes damage to organs (state all organs affected, if known) through prolonged or repeated exposure (state route of exposure if it is conclusively
proven that no other routes of exposure cause the hazard)
- P: 201
Obtain special instructions before use
- P: 210
Keep away from heat/
sparks/open flames/hot
surfaces. — No smoking.
- P: 280
Wear protective gloves/protective clothing/eye protection/face protection.
- P: 304 + 340 + 312
IF INHALED:
Remove victim to fresh air and keep at rest in a position comfortable for breathing.
Call a POISON CENTER or
doctor/physician if you feel
unwell. (Sigma-Aldrich)
- P: 305 + 351 + 338
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact
lenses, if present and easy to do. Continue rinsing.
- P: 308 + 313
IF exposed or concerned: Get medical advice/attention
No statement for this group.
No GHS Classification available at the moment.
Melting point:
-112 °C Boiling Point:
46 °C Density (at 20 °C, if not notified otherwise):
1,26 g/cm3Ionization:
10.073 ± 0.005 eVFlash Point:
< -20 °C Ignition Temperature:
95 °C Vapour Pressure (at 20 °C, if not notified otherwise):
395 hPaLower Explosive Limit:
0,6 Vol.-%Upper Explosive Limit:
60 Vol.-%Hazardous Effects:
R
Also known as:
- Carbon bisulfide
- Carbon disulfide
- Carbon sulfide
- Carbondisulfid
- Dithiocarbonic anhydride
- dithioxomethane
- methanedithione
Get in touch with Dräger
If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.
Suitable products for Carbon disulfide CS2
Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.
Portable Gas Detectors and Sensors
Gas Detection Tubes
Filters
Masks
Powered Air Purifying Respirators and Filters
Protective Suits
Get in touch with Dräger
If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.
Discover more: Dräger VOICE - The hazmat-based safety product finder
You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!