Dräger catalytic Ex sensors

Sensors for Portable Gas Detectors
  • Monitoring of explosive mixtures
  • High resistance to poisoning from silicones and H2S
  • Compatible with the X-am family
  • Measuring range: lower explosion limit up to 100 vol%
Dräger catalytic Ex sensors Sensors for Portable Gas Detectors
DrägerSensor CatEx PR technology, our sensors are resistant to poisoning and particularly stable over the long-term
Dräger Catalytic Ex Sensors - high product quality, low operational costs
Dräger catalytic Ex sensors Sensors for Portable Gas Detectors
Dräger catalytic Ex sensors Sensors for Portable Gas Detectors

Improved safety with our advanced sensor technology

Quick Links
Specifications
Accessories
Downloads
Explore all substances

Highlights

The catalytic DrägerSensors are particularly shock-resistant and have excellent resistance to poisoning. The high product quality and long-term stability ensure low operating costs. Fast response times provide a reliable warning of gas hazards.

Our own design

We develop these sensors with our own engineering knowledge. This way we can assure quality and accurate measurement. This allows them to be utilized to the fullest in combination with our in-house developed Dräger gas detectors.

Shock resistance

The CatEx SR (SR = shock resistant) DrägerSensor is characterised by its particular shock resistance. A fall from great height that exceeds the standard requirements has no effect on the sensor signal. The usual adjustment of the zero point and sensi More information

Durable and resistant to poisoning by sensor poisons

Hydrogen sulphide and silicone are known catalytic poisons that may be present in environments with explosive gas. Thanks to an improved pellistor composition, the sensors are highly resistant to poisoning from these substances. The high resistance t More information

Vapour sensitivity

Unknown gas hazards and higher hydrocarbons pose a particular challenge for the sensitivity display of catalytic sensors. The new CatEx DrägerSensors are particularly sensitive. The detection of all hydrocarbons (from methane to nonane) has been cert More information

Versatile measurement, simple adjustment

Dräger's catalytic sensors are suitable for providing warning of known and unknown flammable gas hazards. The sensors provide the option of setting the device for a variety of different combustible gases or vapours, including hydrogen. If several fla More information

Rapid response times

Rapid warning for explosive gases and vapours is vital. Our CatEx sensors' fast response times minimise the timespan between danger and warning.

Fast adjustment

With the DrägerSensor CatEx SR, fresh air adjustment can be performed after a maximum of only 60 seconds after switching on the device. This saves valuable time and lets you perform a fresh air adjustment shortly before the shift, for example.

From the LEL to 100 vol%

Our catalytic sensors are suitable for measurements in the lower explosion limit range. For methane, measurement up to 100 vol% is also possible.

The X-am 5800 or X-am 8000 features the option to automatically switch the measuring ranges, making it ea More information

Optimised for hydrogen

With the DrägerSensor CatEx H2 100, Dräger also offers a sensor specially optimised for hydrogen applications. With this sensor, measurements can be carried out across the entire measuring range, from a few ppm or %LEL up to 100 vol%. Here too, the o More information

Specifications

Dräger VOICE
Your hazmat-based safety product finder

Relevant information and specific recommendations of safety equipment for more than 1,500 hazardous substances.

See the whole Product System.

This product is part of a Dräger system solution. Combine it with the following system components.

Connective Products

Multi Gas Detectors -    Dräger X-am 2600
Dräger X-am 2600
  • 1 to 4 gas detection device
  • Compatible with Dräger Gas Detection Connect
  • Live monitoring with Gas Detection Connect possible
  • Robust design: IP68 rating
More Information
Multi Gas Detectors - Dräger X-am 3500
Dräger X-am 3500
  • 1 to 4 gas detection device
  • for clearance measurement
  • detection of flammable gases and vapours as well as O2, CO, H2S, NO2 and SO2
More Information
Multi Gas Detectors - Dräger X-am 5000
Dräger X-am 5000
  • 1 to 5 gas detection device
  • for personal air monitoring
  • Detects combustible gases and vapours, as well as O2, CO, H2S, NO2, and SO2
More Information
Multi Gas Detectors - Dräger X-am 8000
Dräger X-am 8000
  • 1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapours and oxygen
More Information
Multi Gas Detectors - Dräger X-am® 2800
Dräger X-am® 2800
  • 1 to 4 gas detection device
  • for personal air monitoring
  • detection of flammable gases and vapours as well as O2, CO, NO2, SO2 and H2S
  • Live monitoring with Gas Detection Connect possible
More Information
Multi Gas Detectors - Dräger X-am® 5800
Dräger X-am® 5800
  • 1 to 6 gas detection device
  • for personal air monitoring
  • detection of flammable gases/vapours, toxic gases as well as oxygen
  • System component of Dräger Gas Detection Connect
More Information
Next Steps

Get in touch with Dräger

Envelop Icon
Dräger Safety AG & Co. KGaA
​F: +971 4 42 94 699 Not all products, features, or services are for sale in all countries. Please contact your local Dräger representative for more information.
​Branch Office P.O. Box 505108 Dubai, United Arab Emirates