Compare

Dräger Flame 1750 H₂ (IR3)

Flame Detectors
  • Specially developed for hydrogen fire detection
  • Triple IR sensor, robust and weatherproof
  • High performance and low false alarm rate
Dräger Flame 1750 H₂ (IR3) Flame Detectors
Compare

Detecting the invisible: Choose the right detector for hydrogen flames

Quick Links
Specifications
Accessories
Downloads
Contact us
Radiation
Measuring Principle
Horizontal 90°, Vertical 90°
Field of view
Typically 4 seconds
Response time
-60°C - 85°C
Temperature (operation)
Open full specifications

Highlights

With its triple IR sensor, the Dräger Flame 1750 H2 detects hydrogen-based fires. It offers you high reliability against false alarms and its good measurement performance remains even at extreme temperatures.

Fast and safe detection

The Dräger Flame 1750 H2 is a triple IR flame detector. It detects hydrogen-based fires even at a greater distance. In just five seconds, it notifies you of a hydrogen fire (1-metre flame) at a distance of up to 40 metres. Due to its certified reliab More information

Dräger Flame 1750 H₂ (IR3) Flame Detectors -

Developed for hydrogen

The Dräger Flame 1750 H2 was specially developed for the detection of hydrogen fires. Its three IR sensors measure only in the 2 to 4 μm range relevant to hydrogen flames, guaranteeing high performance and a low false alarm rate. Common sources of fa More information

Robust and durable

The housing is very robust and weatherproof. To protect against icing and fogging, the window can be heated automatically. This allows you to operate the Flame 1750 H2 reliably even under extreme environmental conditions, e.g. in temperatures from -6 More information

Simple verification

The built-in self-test "Advanced Optical Verification" (AOV) automatically checks the electronics and optics of the Flame 1750 H2. The three-colour LED on the front allows you to quickly see the device status. Green stands for normal operation, yello More information

Specifications

Radiation
Measuring Principle
Horizontal 90°, Vertical 90°
Field of view
Typically 4 seconds
Response time
-60°C - 85°C
Temperature (operation)

Key Facts

Measuring Principle
Radiation
Field of view
Horizontal 90°, Vertical 90°
Response time
Typically 4 seconds
Cable entry
Dual M25 or ¾''NPT
Flameproof
Increased Safety
SIL
SIL 2 (IEC 61508-1-3)
4-20 mA
HART®
RS-485
Relay

Fuel measuring range

Methane
30 m
Ethanol
30 m
n-Heptane
12 m
Diesel Fuel / JP5 / Kerosene
40 m
Propane
30 m
Ethylene glycol
15 m
Gasoline
40 m
Methanol
23 m
IPA (Isopropyl Alcohol)
39 m
Hydrogen
40 m
Acetone
40 m
Hexane
40 m

Technical Data

Power Supply
18 to 32 V DC (24 V DC nominal)
Temperature (operation)
-60°C - 85°C
Humidity
0 to 100 % r.h., non-condensing
Dimensions (H × W × D)
22x10 cm
Weight
6 Kg
Housing Material
Aluminium or stainless steel, powder-coated
IP class
IP66 / NEMA 4X

Approvals

ATEX
IECEx
UL
CSA
CE marking
GOST (EAC)
Performance approval FM3260
Performance approval (DNV Type Approval)
Shipping approval (DNV Type Approval)
FM

See the whole Product System.

This product is part of a Dräger system solution. Combine it with the following system components.

Connective Products

Controller - Dräger REGARD® 3000
Dräger REGARD® 3000
  • Modular control system for various gas and vapour monitoring
  • Multi-coloured status light signals system status
  • Allows combination of Input, Relay, and Gateway modules
More Information
Controller - Dräger REGARD® 7000
Dräger REGARD® 7000
  • Highly expandable control and analysis system
  • Monitors various gases and vapours
  • Suitable for complex gas warning systems
More Information

Downloads

Download product information, instructions for use and other important files.
Next Steps

Get in touch with Dräger

Envelop Icon
Dräger Safety AG & Co. KGaA
​F: +971 4 42 94 699 Not all products, features, or services are for sale in all countries. Please contact your local Dräger representative for more information.
​Branch Office P.O. Box 505108 Dubai, United Arab Emirates