2-PentanolC5H12O
Details
CAS-No.: | 6032-29-7 |
---|---|
UN-No.: | 1105 |
EC-No.: | 227-907-6 |
Hazard identification number: | 30 |
Warning sign
- 30
- 1105
Hazard signs
Occupational exposure limit
- AGW (ppm) 20
- AGW (mg/m3) 73
- H: 226
Flammable liquid and vapour - H: 332
Harmful if inhaled - H: 335
May cause respiratory irritation
- P: 261
Avoid breathing dust/fume/gas/mist/vapours/spray.
- EUH: 066
Repeated exposure may cause skin dryness or cracking
No GHS Classification available at the moment.
Melting point: | |
---|---|
Boiling Point: | |
Density (at 20 °C, if not notified otherwise): | 0,81 g/cm3 |
Ionization: | 9.78 ± 0.03 eV |
Flash Point: | |
Ignition Temperature: | |
Vapour Pressure (at 20 °C, if not notified otherwise): | 5,5 hPa |
Lower Explosive Limit: | 1,2 Vol.-% |
Upper Explosive Limit: | 10,5 Vol.-% |
Details
3 | Flammability: Flammable with normal temperature | |
1 | Instability: Instable when heated | |
1 | Health: Low risk. Filter recommended | |
DG-EA: | 3Y |
Also known as:
- 3-Methyl-2-butanol
- Isoamyl alcohol (secondary)
- pentan-2-ol
- Secondary isoamyl alcohol
Suitable products for 2-Pentanol C5H12O
Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.
Filters
Masks
Powered Air Purifying Respirators and Filters
Get in touch with Dräger
If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.
Discover more: Dräger VOICE - The hazmat-based safety product finder
You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!