Dräger VarioGard 3200 CAT Transmitter
Digital function
The Dräger VarioGard 3200 CAT is connected with the controller via the digital VarioGard bus. This is how it is supplied with electricity and how it transmits its measuring results. You can easily control the entire VarioGard system via the VarioGard bus.
High reliability
The Dräger VarioGard 3200 CAT is equipped with a catalytic DrägerSensor. This sensor measures the concentration of flamable gases in the ambient air. The measured values are transmitted digitally to the controller and displayed there. An alarm is triggered if the gas concentration exceeds one or more of the limit values configured.
Easy operation
Operation is extremely easy. You can make all configurations comfortably from the controller using VarioGard software. You can configure and monitor four current limit values and four averages over time for each transmitter. The alarms are optically and acoustically displayed on the transmitter and transmitted to the controller. A three-colour LED indicates the operating status of the transmitter. The calibration is controlled using a magnetic wand via contact points.
Individually configurable
The VarioGard 3200 CAT is adaptable to your needs. This means that you have different gas libraries available depending upon the desired use: LPG for garages and CH4 for methane monitoring that does not require explosion protection. In addition, you can place the cable inlets on all four sides of the transmitter. The transmitter can be mounted vertically as well as horizontally.
Images and Videos
Downloads
VarioGard System Brochure, en
The Dräger VarioGard central unit is the centre of an affordable and modular gas warning system. Many different transmitters and modules can be connected to the VarioGard central unit.
Digital Communication Brochure, en
Dräger has counted on digital communication for over 30 years. This includes the globally recognised HART®, FoundationFieldbus H1®, Profibus PA® and LON technologies.
Gas Dispersion Brochure, en
Technical Data
Key Facts
- Type
- Transmitter
- Measuring Principle
- Catalytic Bead Sensor
- Response time
- Cable entry
- M20 x 1.5
- Display
- ✗
- Intrinsic Safety
- ✗
- Flameproof
- ✗
- Increased Safety
- ✗
- SIL
- ✗
- 4-20 mA
- ✗
- Bus
- ✓
- HART®
- ✗
- Wireless
- ✗
Technical Data
- Power Supply
- 16 to 30 V DC, 3-wire
- Temperature (operation)
- -20°C - 50°C
- Humidity
- 10 to 95 % r.h., non-condensing
- Pressure (hPa)
- 700 - 1300
- Dimensions (H × W × D)
- 12x11x6 cm
- Weight
- 2.2 lb
- Housing Material
- Aluminum
- Degree of protection (IP class)
- IP65
Approvals
- ATEX
- ✗
- IECEx
- ✗
- UL
- ✗
- CSA
- ✗
- CE marking
- ✓
- GOST (EAC)
- ✗
- Performance approval
- ✗
- Shipping approval
- ✗
- FM
- ✗