Bromine (gaseous)Br2

CAS-No.:
7726-95-6
UN-No.:
1744
EC-No.:
231-778-1
Hazard identification number:
886
Warning sign:
  • 886
  • 1744
Hazard signs
GHS05
GHS06
GHS09
Occupational exposure limit
TRGS 900 (DE/INT)
  • AGW (mg/m3) 0.7
  • H: 314
    Causes severe skin burns
    and eye damage.
  • H: 330
    Fatal if inhaled
  • H: 410
    Very toxic to aquatic life with long lasting effects

  • Melting point:
    -7.2 °C
  • Boiling Point:
    58.7 °C
  • Density (at 20 °C, if not notified otherwise):
    3,11 g/cm3
  • Ionization:
    10.517 ± 0.003 eV
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    233 hPa
  •  
Also known as:
  • Bromine
  • Bromine caswellno112 Great Lakes Bromine
  • Dibromine
  • Molecular bromine

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for Bromine (gaseous) Br2

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Single-gas detector

Dräger Pac® 8000

  • Single-gas detector
  • ​for personal air monitoring 
  • detection of 29 different gases – including special gases such as nitrogen dioxide, ozone or phosgene
  • non-disposable
Multi-gas detector

Dräger X-am® 8000

  • Multi-gas detector
  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapours and oxygen
Multi-gas detector

Dräger X-am® 5000

  • Multi-gas detector
  • ​1 to 5 gas detection device
  • for personal air monitoring 
  • detection of flammable and toxic gases and organic vapours as well as oxygen and harmful concentrations
Multi-gas detector

Dräger X-am® 5600

  • Multi-gas detector
  • ​1 to 6 gas detection device
  • for personal air monitoring 
  • detection of explosive, flammable and toxic gases as well as vapours and oxygen

Dräger X-am® 5800

Electrochemical sensor XXS

DrägerSensor XXS

  • Electrochemical sensor XXS
  • ​monitoring of toxic gases and lack of oxygen
  • compatible with: Pac series and X-am family
  • measuring range: in vol.-% and ppm
Electrochemical sensor XS

DrägerSensor XS

  • Electrochemical sensor XS
  • ​monitoring of toxic gases and oxygen deficiency including hydrides, amines, organic vapours
  • compatible with: X-am 3000 and X-am 7000
  • measuring range: in vol.-% and ...

Gas Detection Tubes

Short-term Tubes

Dräger Short-term Tubes

  • Short-term Tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • display for clear readability of results
  • can be used in explosive areas
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Fixed Gas Detectors and Sensors

Toxic Gases and Oxygen Detector

Dräger Polytron® 8100 EC

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: ...
Toxic Gases and Oxygen Detector

Dräger Polytron® 3000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: with Intrinsic Safety
  • Interface: 4-20 mA
  • IP class: IP66 and SIL1
  • Special: -
Toxic Gases and Oxygen Detector

Dräger Polytron® 5100 EC

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: displays 
Toxic Gases and Oxygen Detector

Dräger Polytron® 6100 EC WL

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: Wireless
  • IP class: 66/67 and SIL2
  • Special: Wireless 
Toxic Gases and Oxygen Detector

Dräger Polytron® 7000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: 4-20 mA, Bus, HART ®
  • IP class: 66/67 and SIL2
  • Special: Display
Toxic Gases and Oxygen Detector

Dräger PointGard 2100

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Non-explosion proof
  • Interface: 4-20 mA, Relays
  • IP class: IP 66
  • Special: Self-contained gas monitor
Electrochemical Gas Detector

Electrochemical DrägerSensor®

  • Electrochemical Gas Detector
  • ​continuous monitoring of poisonous gases and oxygen
  • compatible with: Polytron 8100, Polytron 7000, Polytron 6100, Polytron 5100, Polytron 3000, PointGard ...

Filters

Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...
Respirator filter Rd90

Dräger X-plore® Rd90 Filters

  • Respirator filter Rd90
  • ​Dräger specific Rd90 connection
  • robust aluminium housing
  • to be used in combination with X-plore 4700 half masks
Respirator filter Bayonet

Dräger X-plore® Bayonet

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore 3500 ...

Masks

Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Single-filter full-face mask

Dräger Panorama® Nova

  • Single-filter full-face mask
  • ​different thread connections: RA thread connection Rd40, PE thread connection M45x3, ESA plug-in connector, P Dräger plug-in connection
  • EPDM or silicone mask body, ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40
Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • ​Dräger specific bayonet connection – lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...

Protective Suits

Gas-tight suit

Dräger CPS 7900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit 
  • five suit sizes (S-XXL)
  • side zipper
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 5800

  • Gas-tight suit
  • SCBA worn over the protective suit
  • four suit sizes (M-XXL)
  • diagonal zipper for donning without assistance
  • suit material Zytron® 500, limited use

Gas-tight suit

Dräger CPS 7800

  • Gas-tight suit
  • ​SCBA worn over the protective suit 
  • five suit sizes (S-XXL)
  • diagonal zipper for easy donning and doffing without assistance
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use

Splash Suit

Dräger SPC 4400 / SPC 4800 / SPC 4900

  • Splash Suit
  • Overall with hood (SPC 4400), protective suit with facial cuff (SPC 4800) or full-body protective suit with visor (SPC 4900)
  • CPM (single use) or CLF (limited use)
  • Antistatic version ...
Splash Suit

SPC 4700 with CVA 0700

  • Splash Suit
  • ​Ventilated splash-protective suits
  • Continuous supply of breathing air and cooling airflow (type 3 suit)
  • Coated barrier protection material CPM or carrier fleece material CLF
  • Limited ...

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat