MiraCradle®

​MiraCradle® is an affordable cooling device to induce therapeutic hypothermia among newborns suffering from birth asphyxia. It is easy to use, safe, light weight, portable and gives the precise temperature control of 33–34°C for a period of 72 hours with minimal manual supervision.

MiraCradle® – an affordable solution for developing countries

​MiraCradle® is a CE marked neonatal cooler that enables controlled cooling of newborn infants to support therapeutic hypothermia (TH) for birth asphyxia. The product has been developed with proprietary Phase Change Material (PCM) to maintain the temperature of the infant at 33–34°C (91.4–93.2 F) for the entire treatment duration of 72 hours, consistent with current best practices in treatment. Leveraging sophistication in material engineering, the product offers temperature specificity offered by current servo-devices less than one fifth of the cost.

Safe and easy to use, easy to set up

​MiraCradle® is free of electronics and needs no maintenance. The phase changing material can be charged in a normal refrigerator. After 6–8 hours of charging it is ready to use. The set up is easy and beside the normal temperature monitoring minimal supervision is required.

Precise temperature control

​Two clinical studies have been published in India to show that the temperature stays stable for 72 hours.

The first trial was conducted on 41 babies. The mean (±SD) temperature during the cooling phase was 33.50 ± 0.39°C.Throughout the cooling phase, the target temperature range was maintained in 96.2% of the time. There was no temperature reading <32°C.

Reference: Thomas et al. Phase changing material: an alternative method for cooling babies with hypoxic ischaemic encephalopathy. Neonatology. 2015;107(4):266-70. Epub 2015 Feb. PMID:25720449.

The second trial was conducted on 103 babies and at 10 different hospitals. The median (IQR) of time taken to reach target temperature was 90 (45, 120) minutes. The mean (SD) deviation of temperature during cooling phase was 33.5 (0.39°C). Temperature readings were outside the target range in 10.8% (5.1% of the readings were <33°C and 5.7% were >34°C). Mean (SD) of rewarming was 0.28 (0.13)°C per hour.

Reference: Thomas et al. Phase Changing Material for Therapeutic Hypothermia in Neonates with Hypoxic Ischemic Encephalopathy – A Multi-centric Study. Indian Pediatrics. 2017. Epub 2017 Dec. PMID:29242417.

Economical solution

​Less than 1/5th of the cost of the available electronic devices, long lasting material. No service and maintenance required.

Downloads

MiraCradle Product Information, en
MiraCradle Product Information, en

Download

Infographic Newborn Mortality, en
Infographic Newborn Mortality, en

Download

MiraCradle Brochure Global version, en
MiraCradle Brochure Global version, en

Download

Get in touch with Dräger

Contact Us Image

Draeger Malaysia Sdn. Bhd.

​No. 6, Jalan 15/22, Taman Perindustrian Tiong Nam, Seksyen 15, 40200 Shah Alam,
Selangor Darul Ehsan, Malaysia

+60 3 5526 2000

​Draeger Philippines Corporation

2504-C West Tower, Tektite Towers, Exchange Road, Ortigas Center,
Pasig City 1605 Metro Manila, Philippines

+63 2 8470 3825

Note

Not all products, features or services are for sale in all countries. Please contact your local Dräger representative for more information.

-