Dräger Pac® 6000
Strong performance for maximum safety
You can rely on the Dräger Pac 6000: The personal single gas detection device warns against hazardous concentrations of carbon monoxide, hydrogen sulphide, sulphur dioxide or oxygen with precision and reliability.
Powerful sensors with a very low t-90 response time ensure quick reactions. The Pac 6000 is versatile thanks to its wide measurement range. For example, the CO sensor measures concentrations from 1 to 1,999 ppm, and the H2S sensor from 0.4 to 100 ppm.
Easy handling thanks to clear user guidance
The D-Light indicates whether the functionality of the device has been tested and that it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Dräger Pac 6000 features a clear, well visible colour coding, thereby minimising the chance of mistakes.
Robust design – even for the toughest conditions
The Pac 6000 can easily handle even extreme conditions: depending on the sensor, temperatures from -40 °C to 55 °C and air pressures between 700 and 1,300 mbar can be tolerated.
A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemical-resistant housing meets the requirements specified in the IP68 standard rating.
User-friendly display with all important information
The large display is non-verbal and clearly indicates the respective gas concentration. Other important information, such as remaining operating time and battery capacity, is also displayed. The bright backlighting ensures clear reading of all values in the dark.
360° alarm with various functions
If the Dräger Pac 6000 measures hazardous gas concentrations, it sets off an audible, visual, and noticeable vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic alarm reaches a volume of 90 dB. The display can show the peak concentration measured at any given moment. Earlier alarms registered can also be retrieved at a later time even if acknowledged.
The Pac 6000 with oxygen sensor has two additional alarm thresholds in addition to the standard alarm threshold setting.
Event logger for analyses and reports
The Dräger Pac 6000 logs concentrations and events along with date and time. The data can be downloaded to a PC via an interface and processed further there.
Economical operational costs
All of the versions of the Pac 6000 are equipped with extremely durable DrägerSensors® and a powerful battery. Neither the sensor nor the battery need to be changed for the entire two-year maintenance-free service life of the H2S, SO2 and CO versions. The service life of the Dräger Pac 6000 starts when it is first activated. The device automatically switches off after two years.
The Pac 6000 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled you can quickly and easily replace it yourself. The device is then ready to use again in no time.
Fast function test saves time and money
Function tests and calibrations can be carried out especially efficient using the Dräger X-dock® calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to short test duration and extremely low test gas consumption. The Dräger Pac 6000 is simply placed in the bump test station and automatically selects the correct setting.
Images and Videos
Downloads
Product Information: Dräger Pac® 6000
The disposable personal single-gas detection device, Dräger Pac® 6000, measures CO, H2S, SO2 or O2 reliably and precisely, even in the toughest conditions. The robust design, quick sensor response times, and a powerful battery ensure maximum safety for up to two years with virtually no maintenance required.
Portable Gas Detection Portfolio brochure, en
Gas detectors, sensors and substances
Dräger gas detectors can be used with different sensors to measure a large number of hazardous substances. Check which sensor fits into this detector by searching for a substance. Contact our experts to get more information.
Product configurations
for the gas detector Dräger Pac® 6000
Utilize for 4 Substances
4 matching Sensor(s)
Technical Data
Key Facts
- Sensor type
- Single-Gas Detector
- Measurable gases
- CO, O2, H2S, SO2
- Number of measurable gases
- 1
- Lifetime
- 2 years
Application
- Personal Air Monitoring
- ✓
Technical Data
- Temperature range (device)
- -40°C - 55°C
- Battery service life
- 2 years (24/7)
- Air humidity (relative humidity) in %
- 10% to 90%
- Air pressure (hPa)
- 700 - 1300
- Degree of protection (IP class)
- IP 68
- Weight
- 106 g
Features
- Changable filter
- easy to change from outside / mechanical connection
- D-light
- ✓
- TLV / STEL
- ✗
- Peak
- ✓
- Dual sensor
- ✗
- Alarm Hold
- ✓
Approvals
- ATEX
- ✓ I M1 Ex ia I Ma II 1G Ex ia IIC T4 Ga (Zone 0)
- IECEx
- ✓ Ex ia I Ma Ex ia IIC T4 Ga
- c CSA us
- ✗
- CE
- ✓
- GOST (EAC)
- ✓
- Performance approval
- ✗
- Shipping approval (MED)
- ✗