Dräger Polytron® 5100 EC

The Dräger Polytron® 5100 EC is a cost-effective explosion-proof transmitter for the detection of toxic gases or oxygen in standard applications. It uses a high performance plug-and-play electrochemical DrägerSensor® to detect a specific gas. A 2- or 3-wire 4 to 20 mA output with relays makes it compatible with most control systems.

Toxic Gases and Oxygen Detector

  • Sensor: Electrochemical Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: displays 

Durable, intelligent and sensitive – the DrägerSensor®

With the unique electrochemical Dräger sensors, the Polytron 5100 covers a total of 15 typical gases in various measuring ranges. These long-life sensors provide continuous detection even under the harshest conditions. DrägerSensors offer the industry’s widest temperature range between -40 °C to +65 °C (-40 °F to +150 °F). The built-in memory contains all the necessary calibration and configuration information. The sensors are calibrated ready for immediate operation. The sensor's intrinsically safe connection dispenses with the need for a flame arrestor giving you a faster response time and higher sensitivity.

Same design, same operating principle

Polytron 5100 belongs to the Dräger Polytron 5000 series. All transmitters in this series have the same design and user interface. This allows for uniform operation with reduced training and maintenance requirements. The backlit display shows status information clearly with quick access to functions using a non-intrusive magnetic wand. The gas concentration and measurement unit are displayed during normal operation. Coloured LEDs (green, yellow and red) provide additional alarm and status information.

Three relays for controlling external equipment

The Dräger Polytron 5100 can also be supplied with three integrated relays upon request. This enables you to use it as an independent gas detection system with two adjustable gas concentration alarms and one fault alarm. Audible alarms, signal lights or similar devices can thus be controlled locally without an additional cable between the transmitter and central controller.

Safe, robust housing for every application

The Polytron 5100 features a Class I, Div. 1 rated explosion-proof enclosure made of aluminum or stainless steel, making it suitable for a wide range of environmental conditions. A protection type “e” version includes a convenient docking station enabling installation in hazardous atmospheres without running conduit (where approved) and this also facilitates pre-assembly.

Make the impossible possible with remote sensor

The remote sensor connection housing allows you to install the sensor separately from the transmitter. This allows you to simply place the sensor closer to the gas cloud in hard-to-reach locations. The display remains visible at eye level. Since the sensor is connected via an intrinsically safe connection, no conduit cabling is required. The connection also allows 'hot replacement' of the sensor in the hazardous area.

Downloads

Polytron 5100 EC Product Information, en
Polytron 5100 EC Product Information, en

The Dräger Polytron® 5100 EC is a cost-effective explosion-proof transmitter for the detection of toxic gases or oxygen in standard applications. It uses a high performance plug-and-play electrochemical DrägerSensor® to detect a specific gas. A 2- or 3-wire 4 to 20 mA output with relays makes it compatible with most control systems.

Download

IFU Polytron 5000 Series 9033825 ME
IFU Polytron 5000 Series 9033825 ME

These instructions for use are provided for informational purposes only. Please always read and comply with the instructions for use delivered with the product.

Download

PolySoft 1.20.0 Setup
PolySoft 1.20.0 Setup

20.0​

Download

Sensors and substances

Dräger Sensors for fixed gas detectors can be used to measure a large number of hazardous substances. Check the different sensors by searching for a substance. Get in contact with our experts to get more information.

Search for substance

Please enter a substance

Product configurations

Utilize for 79 Substances

24 matching SensorFGDS

Technical Data

Key Facts

Type
Transmitter
Cable entry
M20 or 3/4" NPT
Display
Intrinsic Safety
Flameproof
Increased Safety
SIL
✗ SIL 2 (IEC 61508-2)
4-20 mA
Bus
HART®
Wireless

Technical Data

Power Supply
10 to 30 V CD, 3-wire
Temperature (operation)
-40°C - 65°C
Humidity
0 to 100% r.h., non-condensing
Pressure (hPa)
700 - 1300
Dimensions (H × W × D)
0.28x0.15x0.13 m
Weight
5 Kg
Housing Material
Epoxy coated copper-free aluminum or stainless steel SS316 L
Degree of protection (IP class)
IP65/66/67

Approvals

ATEX
IECEx
UL
CSA
CE marking
GOST (EAC)
Performance approval
Shipping approval (MED)

Compare with related Products

Get in touch with Dräger

Contact Us Image

​Draeger Singapore Pte Ltd

​Draeger Singapore Pte Ltd
61 Science Park Road The Galen #04-01
Singapore 117525

+65 6872 9288

Draeger Malaysia Sdn. Bhd.

​No. 6, Jalan 15/22, Taman Perindustrian Tiong Nam, Seksyen 15, 40200 Shah Alam,
Selangor Darul Ehsan, Malaysia

+60 3 5526 2000

​Draeger Philippines Corporation

2504-C West Tower, Tektite Towers, Exchange Road, Ortigas Center,
Pasig City 1605 Metro Manila, Philippines

+63 2 8470 3825

Note

Not all products, features or services are for sale in all countries. Please contact your local Dräger representative for more information.

-