Dräger Polytron® 8310 IR
Poison-resistant and fail-safe – the DrägerSensor® IR
DrägerSensor IR is a cost-effective alternative to catalytic bead sensors while offering several benefits: it is poison-resistant against chemicals that can shorten a catalytic bead pellistor’s life. Long life optics result in lower maintenance costs compared to pellistors. IR technology is inherently fail-safe, meaning no unrevealed failures. Improved performance with excellent long-term stability and fast response times.
Easy device management via digital communication
The Dräger Polytron 8310 is equipped with digital interfaces allowing for quick and easy remote interrogation of the transmitter’s state. Integration with existing asset management systems such as PACTware™ is possible via DTM. In addition to the common HART® communication system, the fieldbus interfaces PROFIBUS® PA, FOUNDATION fieldbus™ H1, and Modbus RTU are also available.
Same design, same operating principle
The Dräger Polytron 8310 belongs to the Polytron 8000 series. All transmitters in this series have the same design and user interface. This allows for uniform operation with reduced training and maintenance requirements. The large graphic backlit display shows status information clearly and in an easy to use format. The measured gas concentration, selected gas type, and measuring unit are displayed during normal operation. Colored LEDs (green, yellow and red) provide additional alarm and status information. The Polytron 8310 is operated by means of a magnetic wand over contact surfaces.
Three relays for controlling external equipment
Upon request, the Dräger Polytron 8310 can also be supplied with three integrated relays. This enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm. Audible alarms, signal lights or similar devices can thus be controlled locally without an additional cable between the transmitter and central controller.
Safe, robust housing for every application
Polytron 8310 features a Class I, Div. 1 rated explosion proof enclosure made from aluminium or stainless steel, making it suitable for a wide range of environmental conditions. A protection type “e” version includes a convenient docking station which allows installation in hazardous atmospheres without running conduit (where approved) and this also facilitates pre-assembly.
Make the impossible possible with the remote sensor
The remote sensor connection housing allows you to install the sensor separately from the device electronics. This 'external' installation makes it easier to use if the sensor has to be installed in a difficult to access or unfavourable position.
Data logger
The Polytron 8310 has a data logger, which records measuring and event data from the past years.
Images and Videos
Downloads
Polytron 8310 IR Product Information, en
The Dräger Polytron® 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit (LEL). It uses an infrared DrägerSensor® IR that can be configured for methane, propane or ethylene. Besides a 3 wire 4 to 20 mA analogue output with relays, it also offers HART®, Modbus and Fieldbus protocols making it compatible with most control systems.
Brochure: Digital Communication (PDF)
Dräger has counted on digital communication for over 30 years. This includes the globally recognised HART®, FoundationFieldbus H1®, Profibus PA® and LON technologies.
Explosion Protection Brochure, en
Fixed gas detectors, sensors and substances
Dräger gas detectors can be used with different sensors to detect a large number of hazardous substances. Check which sensor fits into this detector by searching for a substance. Contact our experts to get more information on our wide portfolio.
Product configurations
for the device Dräger Polytron 8310
Utilize for 17 Substances
2 matching Sensor(s)
Technical Data
Key Facts
- Type
- Transmitter
- Measuring Principle
- Infrared
- Response time
- Cable entry
- M20 or 3/4" NPT
- Display
- ✓
- Intrinsic Safety
- ✗
- Flameproof
- ✓
- Increased Safety
- ✓
- SIL
- ✓ SIL 2 (IEC 61508-2)
- 4-20 mA
- ✓
- Bus
- ✓
- HART®
- ✓
- Wireless
- ✗
Technical Data
- Power Supply
- 10 to 30 V DC, 3-wire
- Temperature (operation)
- -40°C - 65°C
- Humidity
- 0 to 100 % r.h., non-condensing
- Pressure (hPa)
- 700 - 1300
- Dimensions (H × W × D)
- 28x15x13 cm
- Weight
- 4 Kg
- Housing Material
- Epoxy coated copper-free aluminum or stainless steel SS 316L
- Degree of protection (IP class)
- IP65/66/67
Approvals
- ATEX
- ✓
- IECEx
- ✓
- UL
- ✓
- CSA
- ✓
- CE marking
- ✓
- GOST (EAC)
- ✓
- Performance approval
- ✓
- Shipping approval
- ✓
- FM
- ✗