SafEye™ Quasar 950/960 Toxic Gases and Oxygen Detectors

SafEye Quasar 950/960

Contact us

SafEye Quasar 950/960

The highly specialised open-path UV gas detection systems Quasar SafEye 950 and 960 provide reliable gas leak monitoring: The Quasar 950 model detects the toxic gases hydrogen sulphide and sulphur dioxide. The Quasar 960 model warns of toxic ammonia.

As far as the SafEye can see

The fixed open path gas detectors of the SafEye Quasar 950 and SafEye Quasar 960 series protect both your staff and the high risk areas of your plant. The sensors in these detectors are distinguished by their high sensitivity and fast response time. With a range of up to 60 m (197 ft), they reliably measure the concentrations of the toxic hazardous substances hydrogen sulphide (H2S) and sulphur dioxide (SO2) as well as ammonia (NH3).

Robust and resistant

You can rely on the SafEye Quasar 950/960 even in extreme and harsh conditions. The heated lenses prevent a reduction in the measuring performance due to ice build-up and snow accumulations. The detector also resists glare and is unaffected by sunlight, natural gas flares, welding arcs and other high intensity radiation. Even strong vibrations cannot harm it.

Complex, but not complicated

The SafEye Quasar 950/960 gas detector is a technically complex product – yet it is very easy to use. It can easily be installed, aligned, calibrated and configured by one person using the handheld unit (available separately).

Compatible with your control system

The SafEye Quasar 950/960 is equipped with different output signals. These are compatible with various industry-standard protocols such as 0 – 20 mA, HART® and RS485 Modbus. In addition, you can select the perfect model with the required range for your system from a wide selection of available versions. This gives you greater flexibility in designing the customised security, monitoring and alarm system for your plant. The approvals for ATEX, IECEx, TR CU and SIL 2 for SafEye 950/960 are available.

Downloads

SafEye Quasar 950/960 Product Information, en-master
SafEye Quasar 950/960 Product Information, en-master

The highly specialised open-path UV gas detection systems Quasar SafEye 950 and 960 provide reliable gas leak monitoring: The Quasar 950 model detects the toxic gases hydrogen sulphide and sulphur dioxide. The Quasar 960 model warns of toxic ammonia.

Download

Gas Dispersion Brochure, en
Gas Dispersion Brochure, en

Download

IFU SafEye Quasar 950/960   en
IFU SafEye Quasar 950/960 en

These instructions for use are provided for informational purposes only. Please always read and comply with the instructions for use delivered with the product.

Download

More than the sum Brochure, en

Get in touch with Dräger

Envelop Icon

​Draeger Singapore Pte Ltd

​Draeger​ ​Singapore​ ​Pte​ ​Ltd
61​ ​Science​ ​Park​ ​Road​ ​The​ ​Galen​ ​#04-01
Singapore​ ​117525

+65 6872 9288

Draeger Malaysia Sdn. Bhd.

​No.​ ​6,​ ​Jalan​ ​15/22,​ ​Taman​ ​Perindustrian​ ​Tiong​ ​Nam,​ ​Seksyen​ ​15,​ ​40200​ ​Shah​ ​Alam,
Selangor​ ​Darul​ ​Ehsan,​ ​Malaysia

+60 3 5526 2000

​Draeger Philippines Corporation

2504-C​ ​West​ ​Tower,​ ​Tektite​ ​Towers,​ ​Exchange​ ​Road,​ ​Ortigas​ ​Center,
Pasig​ ​City​ ​1605​ ​Metro​ ​Manila,​ ​Philippines

+63 2 8470 3825

Draeger Hong Kong Limited.

Room​ ​1701-02,​ ​17/F,​ ​APEC​ ​Plaza,​ ​49​ ​Hoi​ ​Yuen​ ​Road,​ ​Kwun​ ​Tong,​ ​Kowloon​ ​999077,​ ​Hong​ ​Kong

+852 2877-3077

Note:​ ​Not​ ​all​ ​products,​ ​features​ ​or​ ​services​ ​are​ ​for​ ​sale​ ​in​ ​all​ ​countries.​ ​Please​ ​contact​ ​your​ ​local​ ​Dräger​ ​representative​ ​for​ ​more​ ​information.