Dräger SensorAlive H₂S

Sensors for Fixed Gas Detectors
  • Electrochemical sensor with integrated gas generator
  • Daily automatic sensor testing
  • Improves safety and minimises service efforts
Dräger SensorAlive H₂S Sensors for Fixed Gas Detectors
Dräger SensorAlive H₂S
Dräger SensorAlive H₂S
Dräger SensorAlive H₂S with Dräger Polytron® 8100
Dräger SensorAlive H₂S Sensors for Fixed Gas Detectors

Automatic daily self-test with test gas for more safety

Quick Links
Specifications
Accessories
Downloads
Explore all substances

Highlights

Automated Bump Testing For Your Fixed H2S Gas Detectors

The Dräger SensorAlive is an electrochemical sensor with an integrated gas generator. The gas generator enables daily automatic sensor testing with hydrogen sulfide (H2S) as the test gas. It also alerts when the sensor inlet is clogged, preventing gas from reaching the sensor. Daily bump tests help to improve the safety of your gas detection system and allow for extended preventive maintenance intervals.

Dräger SensorAlive Functional Description

Dräger SensorAlive is a self-testing H2S sensor compatible with the Polytron 8100 transmitter and the PointGard 3100 with EC Sensing Remote standalone gas detection system running the latest firmware.

Dräger SensorAlive H₂S Sensors for Fixed Gas Detectors -

LifeTest: Daily automated bump testing

SensorAlive performs a LifeTest on a daily basis to check the function and sensitivity of the integrated electrochemical sensor. The LifeTest consists of two sequential activations of the gas generator, a sensitivity test, and an obstruction test of  More information

Extended calibration interval

Calibration of the electrochemical sensor is still required at regular intervals. During a calibration, the gas generator is also calibrated by SensorAlive at the same time.

The calibration interval of electrochemical sensors can be extended when usin More information

Proven measuring technology

As with all DrägerSensor® electrochemical sensors, the Dräger SensorAlive offers fast response, high accuracy and stability, long service life, and established principles of intrinsic safety for electrical explosion protection.

Coupled with the Dräger More information

Specifications

Dräger VOICE
Your hazmat-based safety product finder

Relevant information and specific recommendations of safety equipment for more than 1,500 hazardous substances.

See the whole Product System.

This product is part of a Dräger system solution. Combine it with the following system components.

Connective Products

Toxic Gases and Oxygen Detectors - Dräger Polytron 8100 EC
Dräger Polytron 8100 EC
  • Top-of-the-line explosion-proof transmitter
  • Monitors toxic gases or oxygen
  • High performance plug and play electrochemical DrägerSensor
More Information

Accessories

Diagnostic Dongle
Diagnostic Dongle
​With the various software dongles, different test and diagnostic functionalities can be activated in the transmitter for application-specific requirements. These sensor tests increase the reliability and safety of the gas detection system. The additional diagnostic functions can automatically correct the sensitivity of the sensor and determine the remaining sensor life.
Dust filter
Dust filter
​Thiy hydrophobic dust filter for electrochemical DrägerSensors (see also the corresponding sensor data specification).
Gassing adapter
Gassing adapter
​This gassing adapter is preferably used for the calibration of electrochemical DrägerSensors. However, it can also serve as a simple bypass adapter in sampling systems.
Remote sensor
Remote sensor
​With the EC Sensing Head Remote, the sensor can be installed up to 30 metres away from the Polytron in a separate compact housing. The separate sensor housing with included field cable is intrinsically safe, which makes installation considerably easier and more flexible. This means that it is not necessary to search for a suitable cable and the sensor’s position can even be adjusted within an Ex zone later on.
Viton® calibration adapter
Viton® calibration adapter
​The flexible, soft calibration adapter, made of Viton®, is used for gassing during zero point test and when calibrating electrochemical DrägerSensors.

Downloads

Download product information, instructions for use and other important files.
Next Steps

Get in touch with Dräger

Envelop Icon
​Draeger Singapore Pte Ltd
​Draeger Singapore Pte Ltd 61 Science Park Road The Galen #04-01 Singapore 117525
Draeger Malaysia Sdn. Bhd.
​No. 6, Jalan 15/22, Taman Perindustrian Tiong Nam, Seksyen 15, 40200 Shah Alam, Selangor Darul Ehsan, Malaysia
​Draeger Philippines Corporation
2504-C West Tower, Tektite Towers, Exchange Road, Ortigas Center, Pasig City 1605 Metro Manila, Philippines
Draeger Hong Kong Limited.
Note: Not all products, features or services are for sale in all countries. Please contact your local Dräger representative for more information.
Room 1701-02, 17/F, APEC Plaza, 49 Hoi Yuen Road, Kwun Tong, Kowloon 999077, Hong Kong