Don’t miss a chance to achieve ventilation weaning progress

As Your Specialist in Acute Care we understand that mechanical ventilation should only take as long as necessary. Otherwise the risk of complications and lung damage increases as well as the ICU length of stay. The crucial factors for successful weaning and extubation are an interdisciplinary strategy and an accurate assessment of the patient.

Wean the patient successfully as third step of the Respiration Pathway

Wean-Pathway-3-2.JPG

Wean the patient quick and safe because ...

  • the incidence of acute lung injuries (ALI) or acute respiratory distress syndrome (ARDS) could delay the induction of weaning
  • the delayed induction of ventilation weaning may lead to weaning failure
  • paying attention to early detection of risk factors may contribute to successful weaning and shorten ICU length of stay

Download full graph

The six phases of the weaning process

There are a series of stages in the process of care, from intubation and initiation of mechanical ventilation through initiation of the weaning effort to the ultimate liberation from mechanical ventilation and successful extubation.

Weaning-Process-3-2.JPG
Evita-V800-3-2-D-2640-2019.jpg

Gentle ventilation with variable pressure support

Making random ventilation changes to imitate the “noise” is an innovative way to improve outcome. Visit our topics page to learn more about Variable Pressure Support. 

Learn more

Evita-V800-PPS-3-2-D-2642-2019.jpg

Allow the patient to take control of ventilation.

Proportional Pressure Support (PPS) applies patient-triggered pressure support in proportion to the patient’s inspiratory effort.

Discover more

Evita-V800-SmartCare-3-2-D-2673-2019.jpg

Improves outcome, shortens ICU stay

SmartCare/PS is an integrated automated clinical protocol that is designed to stabilize the patient’s spontaneous breathing in a comfortable zone of normal ventilation.

Learn more

Early-Mobilisation-Scene-3-2-D-6376-2018.jpg

Early Mobilization

Traditionally, every patient admitted to an ICU is immediately put on enforced bed rest. Research now shows that bed rest can have adverse effects on muscles and organs, which can impair neuropsychological functions and reduce movement capacity.

Discover more

the-pulmovista-500-allows-you-to-visualise-the-distribution-of-ventilation-in-the lungs-3-2

Dräger PulmoVista® 500 – making ventilation visible

PulmoVista 500 helps adjust ventilation settings to achieve individually optimized ventilation with regional specific, continuous and dynamic information at the bedside.

Learn more

Our set of treatment tools to protect the lung

Stabilizing a patient’s breathing means to be well informed about the state of the lung at all times. Let us assist you with a set of proven tools. 

VC-MMV-Autoflow-Screenshot-3-2.jpg

VC-MMV with AutoFlow (Volume Controlled - Mandatory Minute Volume) to support the transition from controlled to assisted spontaneous breathing with a minimum minute ventilation.

PC-BIPAP-3-2.JPG

PC-BIPAP to enable the patient to breathe spontaneously at any time during pressure controlled ventilation.

Automatic-Tube-Compensation-3-2.jpg

ATC - Automatic Tube Compensation to reduce tube related work of breathing to ease spontaneaous breathing.

P0.1-measurement-RSBi-NIF-3-2.jpg

P0.1-measurement,RSBI, NIF to help to asses and quantify the patients ability to breathe spontaneously.

Draeger-SPN-CPAP NIV-Respiratory-Pathway-3-2.jpg

SPN-CPAP-VS to support the spontaneous breathing with guaranteed tidal volume. 

Draeger-SPN-PPS-Tube-ATC-Spont-Breath-II-Respiratory-Pathway-3-2.jpg

SPN-PPS to unload the patient individually for elastic or resistive work of breathing and to avoid asynchrony with proportional assisted ventilation.

SPN-CPAP-ATC-Variable-PS-3-2.JPG

Variable Pressure Support to increase the variability of delivered tidal volume which will lead to improved oxygenation

Comprehensive-Monitoring-Functions-3-2.jpg

Comprehensive monitoring functions like loops, trends logbooks to enable the retrospective analysis of all patient data.

Draeger-Smart-Pulmonary-View-III-Respiratory_Pathway-3-2.jpg

Smart Pulmonary View to perform real time visualization and turn data into information for a potentially quicker analysis of lung dynamic parameters.

Downloads

SmartCare-smartcare-bk-9051398-en-master-1910-5-9-11.JPG
Smart Care Booklet

Learn more about protective ventilation

Download booklet

Ventilation-Mini-Manual- 9-11-9069812.JPG
Mini Manual Ventilation

Learn more about ventilation with our mini manual

Download booklet

NIF Infographic
Did you know? (NIF)

The Negative Inspiratory Force Index (NIF): What is ti? How is it measured? Why is it relevant?

Download infographic

DYK PO.1.jpg
Did you know? (P0.1)

P0.1  has been shown to be a good predictor fo successful weaning

Download infographic

DYK PPS.jpg
Did you know? (PPS)

Porportional Pressure Support (PPS): What is it? When should be applied? Why is it helpful to improve the outcome?

Download infographic

DYK TRIGGER.jpg
Did you know? (Trigger)

The Inspiratory and Expiratory Trigger: What it is? Why is it helpful?

Download infographic

APRV Infographic
Did you know? (APRV)

Airway Pressure Release Ventilation: What is it, why is it helpful to improve outcomes and how to avoid it?

Download infographic

Mandatory Minute Ventilation (MMV) Infographic
Did you know? (MMV)

Mandatory Minute Ventilation (MMV)

Download infographic

DYK Autoflow.jpg
Did you know? (Autoflow)

Autoflow: What is it, why is it relevant and why is it helpful to improve the outcome?

Download infographic

QuickSet Infographic
Did you know? (Quick Setting)

QuickSet: What is it, how to use it, why is it relevant and why is it helpful to improve outcome?

Download infographic

Pressure Link Infographic
Did you know? (Pressure Link)

Pressure Link: What is it, how to use it, why is it relevant and why is it helpful to improve outcomes?

Download infographic

Time Constant Infographic
Did you know? (Time Constant)

Time Constant: What is it, why is it helpful to improve outcomes and how to avoid it?

Download infographic

Autorelease Infographic
Did you know? (Autorelease)

Autorelease: What is it, why is it helpful to improve outcomes and how to avoid it?

Download infographic

Variable Pressure Support Infographic
Did you know? (Variable Pressure Support)

Variable Pressure Support: What is it, why is it helpful to improve outcomes and how to avoid it?

Download infographic

PEEPi Infographic
Did you know? (PEEPi)

PEEPi: What is it, why is it helpful to improve outcomes and how to avoid it?

Download infographic

CO2 Production Infographic
Did you know? (CO2 Production)

CO2 Production: What is it, why is it helpful to improve outcomes and how to avoid it?

Download infographic

Dead Space Volume Infographic
Did you know? (VDS)

Dead Space Volume: What is it, why is it helpful to improve outcomes and how to avoid it?

Download infographic

ETCO2 Monitoring Infographic
Did you know? (ETCO2)

ETCO2 Monitoring: What is it, why is it helpful to improve outcomes and how to avoid it?

Download infographic

Smar Pulmonary View Infographic
Did you know? (SPV)

Smart Pulmonary View: What is it, why is it helpful to improve outcomes and how to avoid it?

Download infographic

Follow the Respiration Pathway

Draeger-Prevent-Respiratory-Pathway-3-2.jpg

Phase 1 - Prevent

Draeger-Stabilize-Respiratory-Pathway-3-2.jpg

Phase 2 - Stabilize

Draeger-Recover-Respiratory-Pathway-3-2.jpg

Phase 4 - Recover

Respiratory-Pathway-3-2.jpg

Your choice for every therapy phase

Would you like to learn more about our set of treatment tools to support individual ventilation therapy along the whole Respiration Pathway?

Visit our main page

Get in touch

Contact us

Дрегер Медикал България ЕООД

бул.Джеймс Баучер 2
гр.София, п.к. 1164

+359 2963 4403

Dräger tehnika d.o.o.

Radoja Dakića 7
110 10 Beograd

+381 11 3911 222

Draeger Hellas S.A.

150, El. Venizelou Str.
142 31 Nea Ionia, Greece

+30 21 0282 1809

Dräger Slovenija d.o.o.

Nadgoriška cesta 19
12 31 Ljubljana-Črnuče

+386 1 561 2263