N,N-DimethylethylamineC4H11N

CAS-No.:
598-56-1
UN-No.:
2734
EC-No.:
209-940-8
Hazard identification number:
883
Warning sign:
  • 883
  • 2734
Hazard signs
GHS02
GHS05
GHS06
GHS07
Occupational exposure limit
TRGS 900 (DE/INT)
  • AGW (mg/m3) 6.1
  • AGW (ppm) 2
  • H: 225
    Highly flammable liquid and vapour
  • H: 302
    Harmful if swallowed.
  • H: 314
    Causes severe skin burns
    and eye damage.
  • H: 331
    Toxic if inhaled
  • H: 335
    May cause respiratory irritation
  • Melting point:
    -140 °C
  • Boiling Point:
    36.5 °C
  • Density (at 20 °C, if not notified otherwise):
    0,675 g/cm3
  • Ionization:
    7.74 ± 0.03 eV
  • Flash Point:
    -28 °C
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    527 hPa
  • Hazardous Effects:
    PBT
  •  
diamond 4 1 2
Details
Diamond-Red4Flammability: Easily flammable 
Diamond-Yellow1Instability: Instable when heated 
Diamond-Blue2Health: Dangerous 
DG-EA:2W
Also known as:
  • Dimethylethylamine
  • DMEA
  • DMEA ethyldimethylamine N,N-dimethylethanamine
  • Ethyldimethylamin
  • Ethyldimethylamine
  • Methanamine
  • Methanamine, N-ethyl-N-methyl-
  • N-Ethyldimethylamine

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for N,N-Dimethylethylamine C4H11N

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Gas Detection Tubes

Short-term Tubes

Dräger Short-term Tubes

  • Short-term Tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Sampling Tubes

Dräger Sampling Tubes and Systems

  • Sampling Tubes
  • ​analysis of the sample in a laboratory
  • measurement of complex compounds and mixtures of substances possible 
  • detection of low concentrations possible 
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • display for clear readability of results
  • can be used in explosive areas
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Fixed Gas Detectors and Sensors

Toxic Gases and Oxygen Detector

Dräger Polytron® 7000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: 4-20 mA, Bus, HART ®
  • IP class: 66/67 and SIL2
  • Special: Display
Toxic Gases and Oxygen Detector

Dräger Polytron® 3000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: with Intrinsic Safety
  • Interface: 4-20 mA
  • IP class: IP66 and SIL1
  • Special: -
Toxic Gases and Oxygen Detector

Dräger Polytron® 5100 EC

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: displays 
Toxic Gases and Oxygen Detector

Dräger Polytron® 6100 EC WL

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: Wireless
  • IP class: 66/67 and SIL2
  • Special: Wireless 
Toxic Gases and Oxygen Detector

Dräger Polytron® 8100 EC

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: ...
Electrochemical Gas Detector

Electrochemical DrägerSensor®

  • Electrochemical Gas Detector
  • ​continuous monitoring of poisonous gases and oxygen
  • compatible with: Polytron 8100, Polytron 7000, Polytron 6100, Polytron 5100, Polytron 3000, PointGard ...

Filters

Respirator filter Rd90

Dräger X-plore® Rd90 Filters

  • Respirator filter Rd90
  • ​Dräger specific Rd90 connection
  • robust aluminium housing
  • to be used in combination with X-plore 4700 half masks
Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...
Respirator filter Bayonet

Dräger X-plore® Bayonet

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore 3500 ...

Masks

Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...
Single-filter full-face mask

Dräger X-plore® 6570

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • silicone mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger Panorama® Nova

  • Single-filter full-face mask
  • ​different thread connections: RA thread connection Rd40, PE thread connection M45x3, ESA plug-in connector, P Dräger plug-in connection
  • EPDM or silicone mask body, ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40
Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • ​Dräger specific bayonet connection – lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...

Powered Air Purifying Respirators and Filters

Filters for PAPR

Dräger X-plore® 8000 Filters

  • Filters for PAPR
  • Particle, gas and combination filters available
  • To be used with powered air purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odour filter

Powered-Air Purifying Respirator

Dräger X-plore® 8000

  • Powered-Air Purifying Respirator
  • Protection without breathing resistance
  • Different breathing filters and head / face pieces available
  • Protection class IP65
  • For Ex zones 1, 2, 21 and 22

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat