Infection Protection in Neonatology - neonatal-infection-prevention-16-6-D-13664-2017.jpg

Infection Protection in Neonatology

Contact Us

Worldwide, more than one in ten babies is born prematurely.25 Premature babies are particularly susceptible to germs due to their weak immune system. The infection protection of these smallest patients must therefore be a top priority in neonatal intensive care units.31

Ein durchdachtes Design der Geräte ist eine wichtige Voraussetzung für eine bessere Hygiene auf der Intensivstation

Workplace

Thoughtful design for better hygiene

The workplace in the neonatal intensive care unit requires the highest hygiene standards. In addition to rules of conduct for hospital staff and parents, this also applies to the equipment and accessories for the treatment of premature babies.31

Der Inkubator Lebensretter für Frühgeborene

The incubator – lifesaver for premature babies

Maintaining a constant temperature inside the incubator is essential, especially for premature babies who are not yet able to regulate their own body temperature.

Our innovative IncuWarm Babyleo TN500 stabilizes the baby's body temperature through three synchronized heat sources: convection heater, radiant heater and heated mattress. These ensure that the temperature in the device remains the same even when the hood is opened – thanks to the stand-by mode, the radiant heater does not require any warm-up time.

Arbeitsplatzgestaltung - Faktoren für bessere Entwicklungsmöglichkeiten

Workplace design – relevant factors for better development opportunities for premature babies

Early skin contact between premature babies and parents – also known as kangarooing – is associated with positive development of the child.37 We therefore took care to support Kangarooing in the workplace design of the Babyleo. Learn more about kangarooing with the Babyleo TN500.

Thermal monitoring brochure

Thermal monitoring in neonatology

What exactly is cold or heat stress? When and how does it develop and what consequences does it have for premature babies? Our booklet deals with this important topic comprehensively and also gives practical tips on how to deal with it.

Babyleo auf Station

Babyleo on ward – experience report of a mother

Maja is the first premature baby in a Dräger Babyleo. In this video, Maja's mother talks about her experiences in the intensive care unit for premature babies. The involvement in the daily care rounds and the Kangaroo Care help her to be very close to Maja and to gain confidence.

Der Selbstschutz aller Mitarbeiter sowie die Maßnahmen zur Erhöhung der Arbeitssicherheit auf der Intensivstation sind besonders wichtig

Occupational Safety

Also when dealing with premature babies – occupational safety is always important!

Occupational safety should be taken into account both in hand hygiene and in the preparation of the sometimes complex incubators, warming beds and respirators. Because of the frequent exposure to chemicals that are part of the cleaners and disinfectants, there is a risk of allergies or diseases of the skin.33 The RKI therefore recommends oxygen releasers for wiping disinfection of incubators.31

Händehygiene Präventionsmaßnahme Neugeborene

Hand hygiene – the most important preventive measure in dealing with newborns

Even more than in any other hospital ward, hand hygiene is a top priority in neonatal intensive care units.32 The frequent cleaning and disinfection of hands can also lead to irritant skin changes or even eczema. The wearing of gloves and appropriate care of the hands are therefore important preventive measures within the framework of employee protection.33

infection-prevention-d-3314-2018-3-2.jpg

For a long time, alcoholic hand disinfectants alone were held responsible for the skin changes. In the meantime, however, it has been shown that these are usually well tolerated, whereas hand washing with detergents is the main cause of skin damage.34

Hand disinfectants listed according to VAH (Association for Applied Hygiene) undergo an evaluation by the VAH Disinfectants Commission, which is based on the European standards DIN EN 1500:2013-07, DIN EN 12791:2005-10, DIN EN 14476:2015-12, DIN EN 13727:2015-12 and DIN EN 13624:2013-12.

Five moments of hand hygiene

1

Before patient contact

2

Before aseptic activities

3

After contact with potentially infectious materials

4

After patient contact

5

After contact with the immediate patient environment

psa-hospital-atemschutz-3-2.jpg

Personal protective equipment in the hospital

PPE approved according to EU Regulation 2016/425

Our products are used where human lives need to be protected, supported and saved. Dräger has more than 100 years of experience in the development and production of respiratory protection.

Aufbereitung Inkubatoren desinfizieren

Preparation of incubators – occupational safety is important!

In addition to the risk of infection through contaminated medical products, there is also the risk of skin damage due to the action of surface disinfectants during processing. Therefore, the protection of the hands is prescribed by the use of appropriate gloves. This is described in DIN EN standards 455-2 and 374-3.

According to DIN EN 455-2, liquid-tight, unpowdered, low-allergen and additionally detergent-resistant protective gloves with extended shaft must be worn for inverting during disinfection and cleaning work.

DIN EN 374-3 states that suitable protective gloves (e.g. made of nitrile rubber) must be worn.

Dräger-Empfehlung über die Verwendung von Zubehör im Falle von multiresistenten Keimen

Infectious Diseases

Infection protection in neonatology always has the highest priority

Sepsis is still one of the leading causes of death in premature babies.30 Premature babies require particularly strict hygiene measures due to their immature immune system and the limited use of antibiotics. If an infection does occur, the challenges not only for healing, but also for preventing it from spreading are very great.

PPE – Safely protected to protect others

Personal protective equipment serves as a mechanical barrier for personnel to protect against pathogens. Depending on the type of pathogen, there are different forms of PSA, which are divided into the following categories according to the RKI 14:

Kategorie 1 umfasst die einfache Schutzausrüstung bei geringem Risiko gesundheitlicher Gefährdung

Category I

Simple protective equipment with low risk of health hazard

Kategorie 2 umfasst Schutzanzüge zur Abwehr von Gefahren

Category II

Protective suits to prevent hazards not covered by categories 1 and 3

Kategorie 3 umfasst die Schutzausstattung im Einsatz gegen tödliche Gefahren oder bei schwerwiegenden gesundheitlichen Folgeschäden

Category III

Protective equipment in use against fatal hazards or serious damage to health

With more knowledge about critical germs you improve the treatment of infections

In February 2017, the WHO published a list of the twelve currently most critical bacterial families. 24 That document draws attention to the particular danger posed by Gram-negative bacteria. They are often resistant to a variety of antibiotics. This makes such infections difficult to treat.

Within the 12 families, the WHO divides the germs into three priority groups: critical, high and medium.

The most critical category includes multi-resistant germs, which are mainly found in intensive care units in hospitals. These include Acinetobacter, Pseudomonas and Enterobacteriecea. These germs can be responsible for pneumonia or catheter-associated infections – often fatal.

Infektiöse Patienten benötigen höchste Schutzvorkehrungen für sich und ihre Umwelt

Patient Protection

Infection protection is patient protection – especially in the neonatal intensive care unit

Up to the 23rd week, premature babies have a high risk of mortality. According to the Federal Health Gazette, the mortality rate before the completed 24th week of pregnancy is ≥50%.26

Infektionskontrolle auf der Neugeborenenstation

Dealing properly with the immature immune system of premature babies

In a premature baby, the skin, which serves as an infection barrier, is not yet fully formed. Furthermore, the nest protection is also not fully developed. These factors make premature babies very susceptible to infections.31

neonatal-care-d-7929-2019-3-2.jpg

Infection control in neonatology

Babies – especially premature babies – are susceptible to hospital-acquired infections. In addition, the symptoms of sepsis in the patient group are difficult to distinguish from other complications. M.D. John Sparks, University of Nebraska Medical Center, USA, explains what effective infection control should consider.

Erstversorgung frühgeborenen Intensivstation

Initial care of premature babies is crucial for further development

The initial care of premature babies takes place immediately after birth and is crucial for further development. In the necessary measures, which serve above all the stabilization of the respiratory and cardiovascular system, it is important to ensure compliance with hygiene standards, as these smallest patients have little defenses. An infection additionally reduces the chances of survival of these smallest patients.

Disposable is added value – especially in the neonatal intensive care unit

Safe handling and maximum infection protection through the use of disposable material. This is already a standard in neonatal intensive care units. Find out here about the portfolio of Dräger original accessories for the care of premature babies.

neonatal-care-ca-9066934-2210-11-4-3.jpg

The Dräger accessories catalogue for neonatology

In our catalogue you will find our entire portfolio of accessories in the areas of ventilation, respiratory limescale, sensors, monitoring, ward devices, splints, examination lights, neonatology and heat therapy.

de_de_neonatologische-intensivstation-3-2.jpg

The room layout in the intensive care unit for premature babies is another important factor for patient protection

The structural conditions in neonatal intensive care units should allow the aseptic preparation of medicines on the ward. This means a separation of "pure" and "impure" care aids. There should always be room for sufficient freedom of movement between incubators and other devices. This also depends on the respective need for care: What additional equipment is needed? And is there still enough space left for Kangaroo Care?31

Case Study

—
Creating an infection-controlled NICU: Karlstad Central Hospital, Sweden

A neonatal intensive care unit optimises its infection protection

Swedish Central Hospital Karlstad has redesigned its 27-year-old neonatal intensive care unit. The result: separate family rooms and separate corridors for parents' access. This division helps to prevent the spread of infectious diseases and at the same time supports developmental care.

neonatal-flow-sensor-D-10946-2016-3-2.jpg

Hygiene Library

In our hygiene library, we have compiled disassembly/assembly and preparation instructions to support you in your daily work. Please also request your personal copy of our manual for the reprocessing of devices and accessories, in which we have summarized the reprocessing of Dräger medical products with uniform surface disinfectants.

Get in touch with Dräger

—
contact-us-hospital-us-1-16-9.jpg
Dräger South Africa (Pty) Ltd.

Johannesburg: 2 Ruacana Street, Waterfall Commercial District, (cnr Beatty Street), Buccleuch, 2090

Postal Address: P.O. Box 4676 Rivonia, 2128 Republic of South Africa  

Dräger South Africa (Pty) Ltd.

Cape Town:  Unit 2, 7 on London, 7 London Circle, Brackengate Business Park, Brackenfell, 7561 

Postal Address: P.O. Box 3677 Tygervalley 7536

Dräger South Africa (Pty) Ltd.

Durban: 17 Thynk Industrial Park Cnr Brickworks and Queen Nandi Drive, Briardene, Durban North, 7561 

Postal Address: P.O. Box 40554 Redhill 4071

Dräger Ghana Ltd.

3rd Floor, EY Tower-Canon House, 60 Rangoon Lane, Cantonments City, Accra - Ghana

Postal Address: P.O Box CT 4412, Cantonments, Accra – Ghana.

Digital Address: GL-045-5249