Dräger Atlan A300/A300 XL Anaesthesia Machines

Dräger Atlan A300/A300 XL

Contact us

Dräger Atlan A300/A300 XL

The new platform offers flexibility for most spatial conditions. The high precision piston ventilator supports lung protective ventilation measures and a comprehensive set of parameters assist decision-making support. The Atlan A300/XL can be networked to communicate securely with other networked devices to share data and information that can help to increase efficiency and reduce errors in anaesthesia.

Lung Protective Ventilation

The electronically controlled electrically driven piston ventilator technology of Atlan A300/XL anaesthesia machine helps to deploy lung protective ventilation measures that can be beneficial for perioperative lung function and may improve outcomes.

  • High precision piston ventilator enables accurate tidal volume delivery down to 5 ml (in VC mode)*
  • Synchronised piston movement with the patient expiration flow reduces the expiratory resistance and can reduce work of breathing
  • The set PEEP is maintained even in case of small leakage and during spontaneous breathing to reduce risk of atelectasis development
  • High trigger sensitivity can detect even weak spontaneous breathing efforts of patients
  • Fresh-gas decoupling seperates the ventilation from the fresh-gas flow and the O2 flush so changes to the fresh-gas flow have no influence on the applied tidal volume and the ventilation pressures
  • Features optimise low- and minimal-flow application, which can contribute to improved humidity of anaesthetic gases, mucociliary clearance, maintenance of body temperature and reduced fluid loss. They include:
    – built-in breathing system warmer to warm breathing gas and to reduce condensation
    – optimised breathing system architecture to enable fast changes in fresh-gas and agent concentrations
    – sample-gas recirculation to eliminate gas loss
  • Lung recruitment maneuver option** comprises One-step and Multi-step recruitment methods, Insp./Exp. Hold function and reminder function to support recruitment maneuver deployment
  • AutoFlow option ensures the delivery of the set tidal volume with the lowest required pressure to avoid pressure peaks and unintentional high tidal volumes
  • Highly accurate APL valve with a nearly linear increase and decrease in pressure pattern


* With option Advanced neonatal support
** Requires software 2.0 or higher

Decision Support

To support you and your staff make informed decisions, our Atlan A300/XL anaesthesia machine can be fitted with multiple options and combinations with other Dräger products.

  • Advanced Gas Monitoring option*:
    – Indicator and trend for efficiency of fresh-gas setting and anaesthetic agent consumption (Econometer and Low Flow Wizard (with no trend)) to support intuitive and convenient application of low- and minimal-flow anaesthesia
    – Access to gas and oxygen consumption and anaesthetic agent uptake data to analyse the low- and minimal-flow practices
    – MV x CO2 parameter to monitor the qualitative display of CO2 elimination
  • Advanced Ventilation Monitoring option:
    – Display of patient lung compliance with trend, P-V and V-Flow loops to assess the ventilation quality and adapt ventilation settings accordingly
  • Compilation of relevant ventilation and haemodynamic patient data in one view display to assess therapeutic effects of lung recruitment maneuver**
  • Guidance for optimised and patient oriented anaesthetic agent delivery in combination with Dräger's SmartPilot View ***


* Only with integrated patient-gas measurement module
** Only with Dräger Infinity Acute Care System (IACS) patient monitoring
*** Software requires medical-grade PC

Infection Prevention and Control

Breaking the chain of infection and complying with your hospital's hygiene protocols is critical in today's clinical environment. For this reason, during the development phase of Atlan anaesthesia machines, we designed them with infection prevention regulations in mind to support hygiene measures in the OR.

  • Quick disassembly of breathing system with few parts to be compliant with infection prevention regulations
  • Smooth and rounded surfaces ease cleaning/wipe disinfection
  • Cable ducts and channels reduce number of potential contamination sources
  • Compatible with original Dräger single-use consumables support hygiene standards
  • Generated message* reminds personnel about the replacement of the RFID technology-based consumables (Infinity ID breathing circuit, Infinity ID WaterLock 2 water trap, Infinity ID flow sensors, Infinity ID CLIC absorber) when their maximum period of use are exceeded
  • Compliant with ISO 17664


* With option Infinity ID Accessories Support

Workflow Efficiency

The design architecture of the Atlan A300/XL anaesthesia machines allows you flexibility to address customer tailored combinations as well as an ergonomic and user-friendly workplace for nearly every size of OR.

  • Scalability among workstation set-up addresses various customer needs and meets spatial conditions of different OR spaces:
    – Compact or large trolley, ceiling or wall variants supports good patient access, ergonomic working environment, and low turnaround times with customised workplaces
    – Comes with or w/o integrated patient-gas measurement module to offer flexibility and avoid redundant cost for clinics with gas bench monitors
  • Standardised Dräger user interfaces, operating principles, nomenclature, and accessories across other Dräger anaesthesia devices and ventilators reduce training efforts, optimise fleet management and reduce risk of errors
  • Graphically illustrated walk-through pre-test checklist enables easy and intuitive preparation of the machine for system test
  • Fully automated system test* (no user interaction needed) enhances operational efficiency and saves staff time for other tasks
  • Auto On** function enables an automatic system test and switching on of the tested machine at a defined time that helps to reduce time for start-up
  • Ex- and import of machine configuration via USB mass storage device saves manual efforts and time**
  • Large work surface, lockable drawer, and additional shelves (optional) for optimal working conditions and supply storage
  • Workplace illumination improves readability during Minimally invasive surgery (MIS) cases
  • Cable management channels reduce cable clutter, connection failures and cleaning efforts
  • Improved manoeuvrability via combination with ceiling supply units simplifies positioning of machine in the OR
  • Anaesthetic agent and gas consumption measurements help to analyse potential savings in agent and gas consumption
  • Generates a message*** when the maximum period of use of the RFID technology-based accessories (Infinity ID breathing circuit, Infinity ID WaterLock 2 water trap, Infinity ID flow sensors, Infinity ID CLIC absorber) are exceeded to remind personnel about the required replacement of consumables
  • Generates message*** when the RFID technology-based Infinity ID breathing bag connector or breathing circuit is connected incorrectly and if the Infinity ID CLIC absorber is not firmly connected to avoid potential human errors
  • Design flexibility enables different mounting positions of hardware components, e.g. patient monitors, IV pumps, IT hardware and shelves, etc., to offer customised workstation solutions


* Variant with integrated O2 monitoring requires weekly calibration of the O2 cell. The pre-use checklist has to be performed by the user prior to the system test.
** This requires software 2.0 or higher
*** With option Infinity ID Accessories Support

Cybersecurity

The Atlan A300/XL anaesthesia machine was designed with security in mind to combat dangerous and damaging cyber-attacks.

We implemented measures considering the NIST security best practices framework.

  • Identify:
    Dedicated documents with security relevant information are provided for asset risk management (e.g. Software Bill of Material, MDS2 Form, comprehensive cybersecurity whitepaper).
  • Protect:
    – A secure boot ensures the integrity of the software running on the device
    – Role-based authentication & authorisation prevents unauthorised access to critical settings and data
    – Hardened operating system by omitting all unnecessary software components and disabling all unused ports minimises attack surface
  • Detect:
    Security relevant events are detected, logged in a tamper-proof security log file and IT-admin is notified via SNMP traps
  • Respond:
    The system health monitor observes the system load carefully and reacts in case of suspected malicious events, i.e., disable network interface if load is unusually high.
  • Recover:
    The system can reboot into last good known state if security event is detected. Dräger service can restore hard- and software quickly, clinical configuration can be transferred from other devices via USB drive


Atlan was developed as to our secure development lifecycle encompassing:

  • Threat analysis to identify vulnerabilities during the development phase
  • Automatic code analysis along software development
  • Independent 3rd party penetration testing to discover residual vulnerabilities
  • Execution only of signed (trusted) code on the device
  • Release of patches if relevant vulnerability was detected
  • Continuous vulnerability monitoring along the lifecycle of the product

Interoperability

The Atlan A300/XL interoperates with other Dräger solutions as an advanced workstation to enhance patient care and workflows. The Atlan A300/XL workstation can be networked to communicate securely with hospital information systems, other networked machines to share data and information that can help to increase efficiency and reduce errors in anaesthesia.

  • Time and date synchronisation*: Identical date and time setting on all connected machines to enable consistent and accurate documentation
  • Data export and EMR Integration*: Collection of high-quality and standardised data from the Atlan workstations which is directly integrated into the patient’s electronic medical record system that reduces time spent on administrative tasks
  • Cardiac bypass mode synchronisation: Activation of Cardiac bypass mode (CBM) on Atlan anaesthesia machine deactivates all alarm monitoring (including arrythmia alarms) and the alarm bar of the connected Dräger patient monitoring during extracorporeal oxygenation of the patient by heart-lung machine
  • Analysis Tool page of the Dräger IACS provides contextual information to assess the effects after a lung recruitment maneuver is performed
  • Mobile Patient Watch: Displays near real-time ventilation numeric parameters and gas analysis waveforms from connected Atlan anaesthesia workstations on a (remote) web-enabled mobile phone or desktop computer to enable remote clinical supervision**


* Requires Dräger Connectivity Converter hardware and is based on ISO/IEEE 11073-Serviceoriented Device Connectivity (SDC) principles
** Optional and subject to applicable/licence terms of use. Requires compatible medical devices and additional IT infrastructure

Data Analytics & Digital Services*

Networked Atlan anaesthesia machines together with Dräger Connect, an innovative cloud-enabled digital business platform for digital solutions and services, can aggregate and process data into valuable information to optimise workflow and cost management:

Gas Consumption Analytics: A comprehensive view of the total consumption of used medical and anaesthetic gases from your connected Atlan workstations per OR and in each OR block.

  • Visualises the consumption and related costs per anaesthetic agent used in one department
  • Indicates the average fresh-gas flow as well as anaesthetic gas consumption and patient uptake ratio
  • Displays average costs per minute and intervention function as economic performance indicators
  • Displays the applied flow rates to support the implementation of low and minimal flow practices
  • Displays the calculated CO2 equivalent based on consumed anaesthetic gases to evaluate the environmental impact


OR Companion: Checks the live status of the connected Atlan workstations to support an effective management of the ORs. Upgrade the solution with the Self-Test Tracker option to streamline staff workflows for the daily anaesthesia system test procedure, protect patients and achieve a high uptime of anaesthesia workstations.

Self-Test Tracker option:

  • Enables remote check of the system test results of all Atlan workstations across departments to optimise and streamline workflows for nursing staff or biomedical engineers
  • Provides a centralised overview of machine system test results to inform staff about machine readiness, and together with the Auto On option of Atlan anaesthesia machine – which enables an automatic system test and switching on of the tested machine at a defined time – can help to reduce time for start-up and streamline staff workflows for the daily anaesthesia machines system test procedure
  • Acts as an assistance system and immediately provides staff with troubleshooting steps


Device Utilisation Analytics: Consolidate all relevant information on the utilisation of your networked Atlan workstations device fleet:

  • Gain insights of the utilisation of your networked Atlan to check its performance and improve efficiency
  • View real-time online network status and operational state of each device
  • Save costs through utilisation analyses and optimisation of the devices fleet with fundamental data insights
  • Provides a comprehensive data basis to support purchase decision making
  • Improves the transparency of software status and updates to avoid security gaps
  • Enables insights into your networked Atlan workstations fleet to support maximum performance and to avoid operational malfunctions


Connected Maintenance**: Supports to increase the uptime of your anaesthesia workstations - keeping them updated, safe and secure.

  • Help Ticket: Delivers fast expert help for technical issues and a higher first-time fix-rate by sending technical device data information with a click of a button
  • Software distribution: Manages software updates efficiently and securely with minimal disruptions to clinical workflows
  • Certificate Management: Medical devices and service tools kept safe and secure by automatic renewals


* Optional and subject to applicable/licence terms of use. Require compatible medical devices and additional IT infrastructure.
** Requires Connectivity Package for establishing the connectivity between devices and Dräger digital services

​Safety Mechanisms

Our Atlan A300/XL machines offer you a wide range of functionalities to help make the anaesthesia process safer for both your patients and clinical staff.

  • Backup manual mode (in case of ventilator, touch screen, or gas mixer failure) to allow manual ventilation while maintaining gas and ventilation monitoring as well as O2 and anaesthetic agent delivery to continue anaesthesia at any time
  • Generates message* when the RFID technology-based Infinity ID breathing bag connector or breathing circuit is connected incorrectly and if the Infinity ID CLIC absorber is not firmly connected to avoid potential human errors
  • Intuitive start in emergency case to reduce waiting time in critical situations
  • O2 real gas test** checks to ensure oxygen is the delivered gas during the system test
  • Automatic xMAC monitoring** to alarm in case of an unintentional drop in concentration of volatile anaesthetics to avoid awareness
  • In case of central gas supply failure and absence of spare gas cylinders, the mechanical ventilation of the patient can be continued with ambient air
  • Automatic and time-controlled*** system test, which includes all relevant components to ensure a safe-to-operate machine so as to enhance patient and personnel safety


* With option Infinity ID Accessories Support
** Only with integrated patient-gas measurement module
*** This requires software 2.0 or higher and Auto On option. The pre-use checklist has to be performed by the user prior to the system test.

Taking responsibility for creating sustainable products

Our technology protects people and the environment. Protecting the environment is therefore not just our duty, but also an opportunity for us to gain a competitive advantage through environmentally friendly products and by conserving resources. For this reason, we make sure that our day-to-day activities, in all areas of the company, protect the environment rather than damage it. We are committed to the United Nations' climate action goals. We handle resources responsibly and work systematically to reduce our carbon footprint. What is more, Dräger products and services help our customers all over the world live up to their responsibility to protect people and the environment.
Learn more:
https://www.draeger.com/en_za/About-Draeger/Sustainability

Downloads

Atlan A300/A300 XL Product Information, en
Atlan A300/A300 XL Product Information, en

Download

Accessory Catalogue 2024, en
Accessory Catalogue 2024, en

Download

Atlan A300/A350 Ceiling and Wall Product Information, en
Atlan A300/A350 Ceiling and Wall Product Information, en

Download

Atlan SW 2.0 and Options Product Information, en
Atlan Software Enhancement Product Information, en
Atlan Declaration of Conformity
IFU Atlan A100 (XL), A300 (XL), A350 (XL) - Reprocessing instructions - Fixed nozzles - 9512621 en
IFU Atlan A100 (XL), A300 (XL), A350 (XL) - Reprocessing instructions - Loose nozzles - 9512984 en
IFU Atlan A100 (XL), A300 (XL), A350 (XL) - SW 2.1n - 9511481 en
IFU Atlan A300, A300 XL, A350, A350 XL - Reprocessing instructions - 9510631 en
IFU Atlan A300, A300 XL, A350, A350 XL - SW 2.0n - 9510601 en
IFU Atlan A300, A300 XL, A350, A350 XL 9056001 en
IFU Connectivity Converter CC300 - Protocol converter SW 1.n 9055930 en
IFU Power socket strup PSS300 9056277 en
IFU SP Atlan A100 (XL), A300 (XL), A350 (XL) - Battery - 9511479 de-me
IFU SP Atlan A100 (XL), A300 (XL), A350 (XL) - SW 2.1n - 9513147 en
IFU SP Atlan A300, A300 XL, A350, A350 XL - Integrated System - 9510696 en
IFU SP Atlan A300, A300 XL, A350, A350 XL - SW 2.0n - 9512143 en
IFU SP Atlan A300, A300 XL, A350, A350 XL 9056596 en
IFU SP Atlan A300, A300 XL, A350, A350 XL SW1.0n 9510692 de-me
IFU SP Atlan A300, A350 ceiling-mounted versions and wall-mounted version 9056443 en
IFU SP Atlan ceiling-mounted version kit - 9512982 de-me
IFU SP Integrated system 9055899 en

Technical Data

Lung Protective Ventilation

Operational Application
Integrated anesthesia workstation for all patients
Patient categories
Adults, pediatrics, neonates
Fresh gas decoupling
Ventilator technology
E-Vent - Uncompromised ventilation quality helps to reduce lung complications and the length of stay
APL-Technology / Precise manual ventilaton
Dräger APL-Valve
Breathing gas warmer
Standard
Low- and minimal flow setting support
Visual filling level of bag; Econometer; Low flow wizard

Ventilation Modes

Man/Spon
CPAP in Man/Spon
Volume Controlled (VC)
VC Synchronized + PS
Pressure Controlled (PC)
PC Synchronized + PS
Pressure Support
Volume Controlled AutoFlow
APRV

Features

Screen Display
15.3" touch-screen with storable view and profiles, smart alarm managment with extensive support system
Vaporizers
Smooth and rounded surfaces ease frequent cleaning/wipe disinfection
Device self test
Automatic self test
LOOPS (p/V-loop and flow/V-loop)
Yes
Smart Pilot View
Yes
Patient gas module
in/ex O2, N2O, CO2, Agent (option with xGM patient gas module)

Technical Data

Device versions
Trolley version, wall version & ceiling version
Breathing system
Integrated; Decision support tools to enhance informed decision making in complex situation
Fresh-gas mixer
mech. mixer with digital flowtubes
Gases
O2, Air, N2O
RFID Technology
Serial interfaces
2 x serial ports (RS232) (MEDIBUS.X protocol), 1 x USB port, 1 x LAN

Safety Concept

Emergency ventilation in case of total gas supply failure
Typical battery run-time in case of power supply failure
typically 120 min
Emergency start-up procedure

Compare with related Products

Get in touch with Dräger

woman blak hair

Dräger South Africa (Pty) Ltd.

​Johannesburg:​ ​2​ ​Ruacana​ ​Street,​ ​Waterfall​ ​Commercial​ ​District,​ ​(cnr​ ​Beatty​ ​Street),​ ​Buccleuch,​ ​2090

+27(0)11 059 4200

​Postal​ ​Address:​ ​P.O.​ ​Box​ ​4676​ ​Rivonia,​ ​2128​ ​Republic​ ​of​ ​South​ ​Africa

Dräger South Africa (Pty) Ltd.

​Cape​ ​Town:​ ​​ ​Unit​ ​2,​ ​7​ ​on​ ​London,​ ​7​ ​London​ ​Circle,​ ​Brackengate​ ​Business​ ​Park​ ​Brackenfell,​ ​7561

+27(0) 21 819 3000

​Postal​ ​Address:​ ​P.O.​ ​Box​ ​3677​ ​Tygervalley​ ​7536

Dräger South Africa (Pty) Ltd.

​Durban:​ ​17​ ​Thynk​ ​Industrial​ ​Park​ ​Cnr​ ​Brickworks​ ​and​ ​Queen​ ​Nandi​ ​Drive,​ ​Briardene,​ ​Durban​ ​North,​ ​7561

+27(0) 31 812 7900

​Postal​ ​Address:​ ​P.O.​ ​Box​ ​40554​ ​Redhill​ ​4071

Dräger Kenya Ltd

Nairobi:​ ​8th​ ​Floor​ ​Office​ ​2,​ ​Sanlam​ ​Tower,​ ​Westlands

+25(0) 47 462 40336

Postal​ ​Address:​ ​PO​ ​Box​ ​2380​ ​–​ ​00606,​ ​Nairobi,​ ​Kenya.