Helping infants with respiratory distress breathe easier.3
The Seattle-Positive Airway Pressure (PAP) system is an innovation which uses the proven advantages of Bubble CPAP therapy, such as oscillatory effects similar to high frequency ventilation1, 2 combined with a unique design. Affordable and easy healthcare for those who need it most.
Availability of the version depending on the country.
Worldwide, almost 1 million infants die each year from respiratory distress. Respiratory muscle exhaustion is a major cause of failure in conventional n-B-CPAP therapy. These failures, which occur in half of babies receiving this therapy, often nece … More information
ssitate endotracheal intubation and mechanical ventilation that carry the risk of tissue damage and inflammation.3The Seattle-PAP from Dräger may be a solution for such complications. The patented Seattle-PAP Bubble CPAP System is designed to create continuous positive airway pressure and pressure oscillations. The 135° angle in the submersed tubing increases the amplitude of oscillations, thus providing effects similar to high frequency oscillatory ventilation for improving gas exchange and offer more efficient respiratory support compared to other methods of non invasive respiratory support.1,2 These oscillations are thought to lessen the work required from respiratory muscles, which would make it easier for babies to breathe.3, 4, 5, 6Regrettably, most of these casualties occur in resource-limited countries due to a lack of access of respiratory support devices commonly used in the developing world. We at Dräger take responsibility for those who can’t afford high-end technology. The Seattle-PAP has the potential to make effective respiratory support accessible to newborns anywhere in the world.Seattle-PAP is safe, effective and easy to use. It was designed to:
Promote infant safety with a uniquely designed pressure manifold with pressure relief valve.
The Seattle PAP has a functional design with a complete focus on the infant’s clinical needs. It is both easy to understand and use. You can:
Time is of the essence in every clinical environment. For this reason, the Seattle-PAP requires minimal training to use. Caregivers can learn to use the device safely and effectively in short time, so they can focus more on the patient rather the ma … More information
naging bedside technology.Inadvertent changes of the position of the tube in the water, thus changing the CPAP level can cause serious harm to your patient. With the Seattle PAP you select your desired settings by locking the tube in the set position. This avoids accidential … More information
changes of CPAP levels and is a unique safety feature. Safety and simplicity with no need to worry.Prevention and control of infections is an additional factor that went into the design concept. Consequently, all components for this system are designed with single-patient use in mind, thus eliminating the risk of cross-contamination.
New innovations and technology should also be affordable for developing countries. Due to the simplicity of the design, the Seattle-PAP is exactly that – affordable respiratory care. This means that effective and life-saving therapy is now available … More information
to many parts of the world that did not have access before.1 Mechanisms of gas transport during ventilation by highfrequency oscillation. J Appl Physiol 1984;56(3):553-563, Chang HK.
2 High-Frequency Oscillatory Ventilation: Theory and Practical Applications, Jane Pillow, Dräger Booklet 9102693 from 2016
3 Sh … More information
ort term evaluation of respiratory effort by premature infants supported with bubble nasal continuous airway pressure using Seattle-PAP and a standard bubble device. PLOS ONE, March 28, 2018, Stephen E. Welty, Craig G. Rusin, Larissa I. Stanberry, George T. Mandy, Alfred L. Gest, Jeremy M. Ford, Carl H. Backes, Jr, C. Peter Richardson, Christopher R. Howard, Thomas N. Hansen, Charles V. Smith4 Bubble CPAP: is the noise important? An invitro study. Pediatr Res 2005;57(6):826-830. Pillow JJ, Travadi JN.5 A comparison of underwater bubble CPAP with ventilator derived CPAP in premature neonates ready for extubation. Biol Neonate 1998;73(2):69-75, Lee KY, Dunn MS, Fenwick M, Shennan AT.6 A Study to Evaluate the Efficacy of Seattle-PAP for the Respiratory Support of Premature Infants, ClinicalTrials.gov Identifier: NCT030853297 Effects of condensate in the exhalation limb of neonatal circuits on airway pressure during bubble CPAP. Respir Care. 2013 Nov;58(11):1840-6. doi: 10.4187/respcare.02322. Epub 2013 Mar 12, Youngquist TM1, Richardson CP, Diblasi RM.