Compare

Dräger X-am 3500

Multi Gas Detectors
  • 1 to 4 gas detection device
  • for clearance measurement
  • detection of flammable gases and vapours as well as O2, CO, H2S, NO2 and SO2
Dräger X-am 3500 Multi Gas Detectors
The X-am 3500 is specially designed for use with a pump and optimised for clearance measurement.
The multi-gas detector is intuitive to operate single-handedly using three function keys.
The colour display of the multi-gas monitor is easy to read and ensures optimum safety and easy handling.
With a pedestal the 4 gas monitor can be used for area monitoring.
Dräger X-am 3500 Multi Gas Detectors
Dräger X-am 3500 Multi Gas Detectors
Dräger X-am 3500 Multi Gas Detectors
Dräger X-am 3500 Multi Gas Detectors
Dräger X-am 3500 Multi Gas Detectors
Dräger X-am 3500 Multi Gas Detectors
Dräger X-am 3500 Multi Gas Detectors
Compare

Boosting your safety with our portable gas detectors: Where trust meets technology

Quick Links
Specifications
Accessories
Downloads
Explore all substances
1 - 4
Number of gases
CAT + EC
Sensor technology
No
Smart Configuraton in Dräger Gas Detection Connect
C7H14O3, C4H10O2, C4H6, C4H8O, C5H12O, C3H8O, C2H4O2, C6H12O2 and more
Substances
See all relevant substances
Open full specifications

Highlights

The Dräger X-am 3500 was especially designed for clearance measurements. The 1 to 4 gas detector reliably detects flammable gases and vapours as well as O2, CO, H2S, NO2 and SO2. The innovative signalling design and extensive range of accessories ensure optimum safety and easy handling.

Specially designed for use with a pump, optimised for clearance measurement

The Dräger X-am 3500 is equipped with a very powerful pump. It can be connected with hoses of up to 45 metres in length. A pump adapter makes it easy to switch between diffusion and pump mode at any time. This means the pump is only operated when you More information

Clear signalling design

The signal system of the Dräger X-am 3500 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:

  • Red light = gas alarm
  • Yellow light = device-related alarm, e.g. low battery
  • Green light = devic More information

Economical Fleet Management

Bumptest and calibration are carried out simply and quickly using the Dräger X-dock calibrating station. Its low test gas consumption keeps operating costs to a minimum.

Its reporting function and numerous other useful features make the Dräger Gas Det More information

Inductive charging protects against wear and tear

The X-am 3500 features inductive charging. This makes it easier to operate and increases the lifespan of the device. Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazar More information

Specifications

1 - 4
Number of gases
CAT + EC
Sensor technology
No
Smart Configuraton in Dräger Gas Detection Connect
C7H14O3, C4H10O2, C4H6, C4H8O, C5H12O, C3H8O, C2H4O2, C6H12O2 and more
Substances
See all relevant substances

Key Facts

Measurable gases
Ex, O2, CO, H2S or NO2 or SO2
Sensorports
4
Number of gases
1 - 4
Sensor technology
CAT + EC

Applications

Personal Air Monitoring
Confined Space Entry
Area Monitoring

Technical Data

Operation time
>24h
Dimensions (W × H × D)
7.7x17.9x4.2 cm
Weight
1.1 lb
Battery type
Li-Ion
Degree of protection (IP class)
IP 68

Features

Dual sensors
CatEx Fullrange
D-Light
Internal pump
X-am Pump
X-zone 5500 Area Monitoring
Bump Test Station
X-dock Station
Bluetooth
Bodyguard Alarm (Panic alarm, Motionless detection)
Smart Configuraton in Dräger Gas Detection Connect
Support of Dräger ConHub (Gateway)

Approvals

ATEX
I M1, II 1G, Ex da ia I Ma, Ex da ia IIC T4 Ga
IECEx
I M1, II 1G, Ex da ia I Ma, Ex da ia IIC T4 Ga
c CSA us
Class I, Zone 0, AEx da ia IIC T4 Ga Class II, Div 1, Gr. E, F, G
CE
GOST (EAC)
PO Ex da ia I Ma X, 0Ex da ia IIC T4 Ga X
Performance approval
Shipping approval (MED/DNV GL)

Dräger VOICE
Your hazmat-based safety product finder

Relevant information and specific recommendations of safety equipment for more than 1,500 hazardous substances.

See the whole Product System.

This product is part of a Dräger system solution. Combine it with the following system components.

Connective Products

Sensors for Portable Gas Detectors - Dräger Catalytic Ex-Sensors
Dräger Catalytic Ex-Sensors
  • monitoring of explosive mixtures
  • high poisoning resistance to silicones and H2S
  • compatible with: X-am family
  • measuring range: lower explosion limit up to 100 vol.-%
More Information
Sensors for Portable Gas Detectors - Dräger Infrared Sensors
Dräger Infrared Sensors
  • monitoring of explosive mixtures and CO2
  • recommended for frequent occurrence of explosive gases
  • compatible with X-am 5600 / 7000 / 8000
  • measuring range: lower explosion limit up to 100 vol.%, for CO2 0 - 5 vol.%
More Information
Calibration and Bump Testing - Dräger X-dock 5300/6300/6600
Dräger X-dock 5300/6300/6600
  • Provides full control of portable Dräger gas detection instruments
  • Automatic bump tests and calibrations
  • Comprehensive documentation and evaluations
More Information
Sensors for Portable Gas Detectors - DrägerSensor XXS
DrägerSensor XXS
  • Miniature electrochemical sensors
  • monitoring of toxic gases and lack of oxygen
  • compatible with: Pac series and X-am family
  • measuring range: in vol.-% and ppm
More Information
Sensors for Portable Gas Detectors - PID sensors
PID sensors
  • detection of volatile organic compounds in low concentrations
  • compatible with: X-am 7000 and X-am 8000 - selective benzene measurement with pre-tubes possible
  • measuring range: in ppm and ppb range
More Information

Accessories

   Shoulder Strap with adhesive label for X-am
Shoulder Strap with adhesive label for X-am
With the shoulder strap you can comfortably carry the deivce. The corresponding adhesive label can be marked individually with device specific information, e.g. sensor assortment.
Calibration and Bump Testing - Calibration gas and accessories
Calibration gas and accessories
  • Ensures safe operation and functionality of equipment
  • Offers various calibration gas options.
  • Meets applicable regulations and codes of practice
More Information
Multi Gas Detectors - Dräger X-am® Pump
Dräger X-am® Pump
  • External pump for Dräger X-am® 2500/2800 and X-am ® 5000/5600/5800
  • for clearance measurement
  • Automatically switches on when connected to a running X-am® device
More Information
Inductive charger
Inductive charger
​​To charge the device inductively
Pedestal
Pedestal
To stand the device upright for area monitoring. The pedestal can be used with or without a shoulder strap.
Protective rubber boot
Protective rubber boot
Prevents damage and wear in harsh environments. The protective boot can easily be replaced by the user.

Software

Portable Gas Detection Software - Dräger Configuration and Evaluation Software
Dräger Configuration and Evaluation Software
  • Enables saving measurement results and configuring gas detection instruments
  • Provides detailed analysis of data collected by portable gas detectors
More Information

Need Software Updates?

Software updates for this product are available in the download area.
Downloads
Next Steps

Get in touch with Dräger

woman black hair
Dräger South Africa (Pty) Ltd.
​Postal Address: P.O. Box 4676 Rivonia, 2128 Republic of South Africa
​Johannesburg: 2 Ruacana Street, Waterfall Commercial District, (cnr Beatty Street), Buccleuch, 2090
Dräger South Africa (Pty) Ltd.
​Postal Address: P.O. Box 3677 Tygervalley 7536
​Cape Town: Unit 2, 7 on London, 7 London Circle, Brackengate Business Park Brackenfell, 7561
Dräger South Africa (Pty) Ltd.
​Postal Address: P.O. Box 40554 Redhill 4071
​Durban: 17 Thynk Industrial Park Cnr Brickworks and Queen Nandi Drive, Briardene, Durban North, 7561
Dräger Kenya Ltd
Postal​ ​Address:​ ​PO​ ​Box​ ​2380​ ​–​ ​00606,​ ​Nairobi,​ ​Kenya.
Nairobi:​ ​8th​ ​Floor​ ​Office​ ​2,​ ​Sanlam​ ​Tower,​ ​Westlands