Compare

Dräger X-am 5000

Multi Gas Detectors
  • 1 to 5 gas detection device
  • for personal air monitoring
  • Detects combustible gases and vapours, as well as O2, CO, H2S, NO2, and SO2
Dräger X-am 5000 Multi Gas Detectors
The X-am 5000 is a 5 gas monitor and is developed especially for personal monitoring applications.
Dräger X-am 5000 Multi Gas Detectors
Dräger X-am 5000 Multi Gas Detectors
Dräger X-am 5000 Multi Gas Detectors
Dräger X-am 5000 Multi Gas Detectors
Dräger X-am 5000 Multi Gas Detectors
Compare

Boosting your safety with our portable gas detectors: Where trust meets technology

Quick Links
Specifications
Accessories
Downloads
Explore all substances
1 - 5
Number of gases
CAT + EC
Sensor technology
Yes
Smart Configuraton in Dräger Gas Detection Connect
C4H10O2, C4H6, C4H8O, C5H12O, C4H10S, C3H8O, C3H3N, C2H4O and more
Substances
See all relevant substances
Open full specifications

Highlights

The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as oxygen and harmful concentrations of toxic gases, organic vapors, Odorant and Amine.

Ergonomic design

Despite its advanced functionality, the Dräger X-am 5000's practical design and light weight make it comfortable to carry. Reduced to its essentials, the two button control panel and easy to follow menu allow for intuitive use.

Flexible sensor exchange

It is easy to exchange, upgrade or calibrate the sensors to other gases. The ability to customize the Dräger X-am 5000's sensors makes more applications possible, including rental equipment.

Poison-resistant Ex sensor

For improved safety when facing unknown and potentially explosive hazards – the Dräger X-am 5000 provides dependable warnings in the event of explosive atmospheres thanks to the high level of sensitivity of the innovative catalytic Ex sensor. It not  More information

Durable sensor technology

The Dräger X-am 5000 is equipped with powerful and durable Dräger sensors.

Robust and watertight

The Dräger X-am 5000 is water and dust resistant according to IP 67 standards. This means that the detector remains fully functional and ready for use even after being dropped into water. The integrated rubber protection and shock-proof sensors provi More information

External pump

The optional external pump, which operates with a hose up to 45 meters long, makes it possible to use the detector for pre-entry measurements into confined spaces such as tanks, shafts, etc. The pump starts automatically when the detector is attached More information

Area monitoring

In combination with the Dräger X-zone 5500/5800 the gas detector can be used for various area monitoring applications. Up to 25 Dräger X-zone 5500/5800 units can be automatically interconnected to form a wireless fenceline. This interconnection of th More information

Optimum solutions for function or bump tests and calibrations

Simple, fast and professional: from a function or bump test to complete documentation, users can choose from a range of practical, on-site solutions that offer maximum safety for every application. The automatic test and calibration station Dräger X- More information

Flexible power supply

The Dräger X-am 5000 can be used with alkaline batteries. In addition, it can be fitted with a rechargeable NiMh T4 battery that can be charged while still inside the instrument. An optional Save Energy Mode makes it possible to increase the operatin More information

360° Product View

Draeger X-am 5000 360

Specifications

1 - 5
Number of gases
CAT + EC
Sensor technology
Yes
Smart Configuraton in Dräger Gas Detection Connect
C4H10O2, C4H6, C4H8O, C5H12O, C4H10S, C3H8O, C3H3N, C2H4O and more
Substances
See all relevant substances

Key Facts

Measurable gases
Ex, O2, CO, H2S, NO2, SO2, + (choice out of > 40 sensors)
Sensorports
4
Number of gases
1 - 5
Sensor technology
CAT + EC

Applications

Personal Air Monitoring
Confined Space Entry
Area Monitoring

Technical Data

Operation time
>12h
Dimensions (W × H × D)
4.8x13x4.4 cm
Weight
7.76 oz
Battery type
NiMh
Degree of protection (IP class)
IP 67

Features

Dual sensors
CatEx Fullrange
D-Light
Internal pump
X-am Pump
X-zone 5500 Area Monitoring
Bump Test Station
X-dock Station
Bluetooth
Bodyguard Alarm (Panic alarm, Motionless detection)
Smart Configuraton in Dräger Gas Detection Connect
Support of Dräger ConHub (Gateway)

Approvals

ATEX
I M1 Ex da ia I Ma, II 1G Ex da ia IIC T4/T3 Ga
IECEx
Ex da ia I Ma, Ex da ia IIC T4/T3 Ga
c CSA us
Class I Div. 1 Group A, B, C, D, E, F, T4/T3 | A/Ex da ia IIC T4/T3 /Ga
CE
GOST (EAC)
PO Ex da ia I Ma X 0Ex da ia IIC T4/T3 Ga X
Performance approval
Shipping approval (MED/DNV GL)

Dräger VOICE
Your hazmat-based safety product finder

Relevant information and specific recommendations of safety equipment for more than 1,500 hazardous substances.

See the whole Product System.

This product is part of a Dräger system solution. Combine it with the following system components.

Connective Products

Calibration and Bump Testing - Dräger Bump Test Station
Dräger Bump Test Station
  • Function testing for gas detection and warning devices
  • Simple, cordless and portable
More Information
Sensors for Portable Gas Detectors - Dräger Catalytic Ex-Sensors
Dräger Catalytic Ex-Sensors
  • monitoring of explosive mixtures
  • high poisoning resistance to silicones and H2S
  • compatible with: X-am family
  • measuring range: lower explosion limit up to 100 vol.-%
More Information
Fire Simulation Systems - Dräger FTS 8000
Dräger FTS 8000
  • Mobile fire training system for fire brigades
  • Enables safe real fire training with wood-, gas-, and liquid gas-fired fire sites
  • Offers diverse training scenarios for firefighters at all levels
More Information
Multi Gas Detectors - Dräger X-am® 5800
Dräger X-am® 5800
  • 1 to 6 gas detection device
  • for personal air monitoring
  • detection of flammable gases/vapours, toxic gases as well as oxygen
  • System component of Dräger Gas Detection Connect
More Information
Calibration and Bump Testing - Dräger X-dock 5300/6300/6600
Dräger X-dock 5300/6300/6600
  • Provides full control of portable Dräger gas detection instruments
  • Automatic bump tests and calibrations
  • Comprehensive documentation and evaluations
More Information
Sensors for Portable Gas Detectors - DrägerSensor XXS
DrägerSensor XXS
  • Miniature electrochemical sensors
  • monitoring of toxic gases and lack of oxygen
  • compatible with: Pac series and X-am family
  • measuring range: in vol.-% and ppm
More Information
Leather carrying case for X-am pump
Leather carrying case for X-am pump
The leather case is designed to protect the X-am device and pump. It is equipped with a belt loop on the reverse and can be used to support the pump when it is separated from the X-am.

Accessories

Calibration and Bump Testing - Calibration gas and accessories
Calibration gas and accessories
  • Ensures safe operation and functionality of equipment
  • Offers various calibration gas options.
  • Meets applicable regulations and codes of practice
More Information
Multi Gas Detectors - Dräger X-am® Pump
Dräger X-am® Pump
  • External pump for Dräger X-am® 2500/2800 and X-am ® 5000/5600/5800
  • for clearance measurement
  • Automatically switches on when connected to a running X-am® device
More Information
Rechargeable battery and charging technology set
Rechargeable battery and charging technology set
NiMH supply unit T4 with charger module und power pack

Software

Portable Gas Detection Software - Dräger Configuration and Evaluation Software
Dräger Configuration and Evaluation Software
  • Enables saving measurement results and configuring gas detection instruments
  • Provides detailed analysis of data collected by portable gas detectors
More Information

Need Software Updates?

Software updates for this product are available in the download area.
Downloads
Next Steps

Get in touch with Dräger

woman black hair
Dräger South Africa (Pty) Ltd.
​Postal Address: P.O. Box 4676 Rivonia, 2128 Republic of South Africa
​Johannesburg: 2 Ruacana Street, Waterfall Commercial District, (cnr Beatty Street), Buccleuch, 2090
Dräger South Africa (Pty) Ltd.
​Postal Address: P.O. Box 3677 Tygervalley 7536
​Cape Town: Unit 2, 7 on London, 7 London Circle, Brackengate Business Park Brackenfell, 7561
Dräger South Africa (Pty) Ltd.
​Postal Address: P.O. Box 40554 Redhill 4071
​Durban: 17 Thynk Industrial Park Cnr Brickworks and Queen Nandi Drive, Briardene, Durban North, 7561
Dräger Kenya Ltd
Postal​ ​Address:​ ​PO​ ​Box​ ​2380​ ​–​ ​00606,​ ​Nairobi,​ ​Kenya.
Nairobi:​ ​8th​ ​Floor​ ​Office​ ​2,​ ​Sanlam​ ​Tower,​ ​Westlands