Dräger X-am® 8000

Clearance measurement was never this easy and convenient: The 1 to 7 gas detector detects toxic and flammable gases as well as vapours and oxygen all at once – either in pump or diffusion mode. Innovative signalling design and handy assistant functions ensure complete safety throughout the process.

Specially designed for use with a pump, optimised for clearance measurement

The Dräger X-am® 8000 is equipped with a very powerful pump. It can be connected with hoses of up to 45 metres in length. A pump adapter makes it easy to switch between diffusion and pump mode at any time. This means the pump is only operated when you actually need it. That saves energy, reduces wear and tear, and thereby extends the lifespan of the pump.

Handy and durable, the Dräger X-am® 8000 is intuitive to operate single-handedly using three function keys. The easy-to-read colour display clearly lays out all the information for you.

The multi-gas detector also features advanced software functions including change of measurement gas for PID, CatEx and IR sensor during operation. This is based on an on-board libary and a comfortable assistant to hide unused sensor channels to adapt the instrument flexible to the measurement task.

Standard accessories include a sturdy shoulder strap, so you can comfortably carry the X-am 8000. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.

Clearance measurement, release and documentation in no time

The X-am 8000 effectively supports various applications with specially developed assistant functions that guide you through each process step by step. During clearance measurement, for example, the smart assistant calculates the necessary flooding time for the device and probe (FKM hose) based on parameters such as measuring gases, temperature limits, and the indicated hose length. Additionally, customer defined flooding times are also possible.

When monitoring for possibly high methane concentrations, an optional automatic measurement range switch makes it easier to take a reading: if the Cat-Ex sensor measures values above 100 % LEL, the display switches to the range of 0 to 100 vol %. A similar function to measure in % LEL and vol% simultanously is also available for the IR EX ES sensor.

The DrägerSensor CatEx 125 PR Gas offers a special variant for the measuring gas methane, which enables measurements in the ppm range.

The performance of selected sensors has been verified by an external approval body within the scope of the measurement performance approval (EN 60079-29-1), for combustible gases and vapours for methane, propane and n-nonane, among others.

Clear signalling design

The signal system of the Dräger X-am 8000 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:

  • Red light = gas alarm
  • Yellow light = device-related alarm, e.g. low battery
  • Green light = device is ready for use

The green glow of the D-Light allows you to see from a distance whether the device has been properly tested and is ready for use.

In case of an alarm, the X-am 8000 alerts you with colourful alarm LEDs, a loud horn (100 dB(A) at a distance of 30 cm), and clearly palpable vibration. Optionally, four preset hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows the user to easily recognise the type of hazard based purely on the symbol displayed.

The X-am 8000 is equipped with an impact detection system. The event report indicates whenever severe mechanical impacts have occurred that might result in functional impairments of the device or the sensors. These are also documented in the data logger. With this information, a device attendant can specifically check the device. As an option the instrument can be locked after a detected impact as well.

Economical Fleet Management

Bumptest and calibration are carried out simply and quickly using the Dräger X-dock® calibrating station. Its low test gas consumption keeps operating costs to a minimum.

Its reporting function and numerous other useful features make the Software Dräger Gas Detection Connect a smart addition to any fleet management operation. To identify the devices in the fleet, you can either use tried and tested barcodes or an integrated RFID transponder.

Specialist for high and low hydrocarbon concentrations

To measure hard-to-detect hydrocarbons, you can fit the Dräger X-am 8000 with one of two high-performance PID sensors. The PID HC covers a measurement range of 0 to 2,000 ppm (Isobutene). The PID LC ppb is particularly suited for a measurement range of 0 to 10 ppm (Isobutene) with a high resolution in the range below 1 ppm.

For benzene-specific measurements, the X-am 8000 can be used with a pre-tube. The advantage: you only need one measuring device for this application, which significantly reduces the costs of purchasing, maintaining and transporting devices in use. The use of the pre-tubes is supported by a built-in assistant.

Inductive charging protects against wear and tear

The X-am 8000 features inductive charging. This makes it easier to operate and increases the lifespan of the device. Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) and measure at once, e.g, when in use inside vehicles or on machinery.

The charging cradle can connect with one another, taking up minimal space, and are compatible with existing Dräger X-am® series cradles.

Downloads

X-am 8000 Product Information, en
X-am 8000 Product Information, en

Clearance measurement was never this easy and convenient: The 1 to 7 gas detector detects toxic and flammable gases as well as vapours and oxygen all at once – either in pump or diffusion mode. Innovative signalling design and handy assistant functions ensure complete safety throughout the process.

Download

CC-Vision Basic 8.1.2
CC-Vision Basic 8.1.2

Release Date: 05th August, 2024

Download

Portable Gas Detection Portfolio brochure, en
Portable Gas Detection Portfolio brochure, en

Download

Brochure: Dräger sampling hoses for portable gas detectors
CC-Vision Software History, en
DrägerSensor & Portable Instruments Handbook (6th Edition), en
Driver for DIRA and MILO Interface
GasVision Software History, en
GasVision Version 8.0.5
IFU PID pre-filter tube benzene (8103511) - 9022880 da-me
IFU PID-Pre-Filter Tube Humidity 9022882 da, de me
IFU SP Adapter for power supply plug, X-am charging cradle 9033811 ME
IFU SP PID substance list 9300316 de-me
IFU SP Truck mount for X-am 8000 9033807 ME
IFU SP X-am 2500/2800/3500/5000/5100/5600/5800/8000 - Limited Manufacturer Guarantee - 9033743 af-me
IFU SP X-am 3500/8000 9033806 en
IFU SP X-am 8000 - Inductive Power Unit - Notes on Approval - 9300059 en-me
IFU SP X-am 8000 / DrägerSensor PID 9100201 de, en me
IFU Technical Manual X-am 3500/8000 9033665 en
IFU X-am 3500 / 8000 - Notes on approval / Sensor data - 9033655 en
IFU X-am 8000 - 9033654 de-me

Gas detectors, sensors and substances

Dräger gas detectors can be used with different sensors to measure a large number of hazardous substances. Check which sensor fits into this detector by searching for a substance. Contact our experts to get more information.

Search for substance

Please enter a substance

Product configurations

for the gas detector Dräger X-am® 8000

Utilise for 127 Substances

37 matching Sensor(s)

Technical Data

Key Facts

Measurable gases
Ex, CO2, O2, CO, H2S, NO2, SO2, VOC (PID) + (choice out > 40 sensors)
Sensorports
5
Number of gases
1 - 7
Sensor technology
CAT + IR + PID + EC

Applications

Personal Air Monitoring
Confined Space Entry
Area Monitoring

Technical Data

Operation time
>24h
Dimensions (W × H × D)
7.7x17.9x4.2 cm
Weight
1.32 lb
Battery type
Li-Ion
Degree of protection (IP class)
IP 68

Features

Dual sensors
CatEx Fullrange
D-Light
Internal pump
X-am Pump
X-zone 5500 Area Monitoring
Bump Test Station
X-dock Station
Bluetooth
Bodyguard Alarm (Panic alarm, Motionless detection)
Smart Configuraton in Dräger Gas Detection Connect
Support of Dräger ConHub (Gateway)

Approvals

ATEX
✓ I M1, II 1G, Ex da ia I Ma, Ex da ia IIC T4 Ga
IECEx
✓ I M1, II 1G, Ex da ia I Ma, Ex da ia IIC T4 Ga
c CSA us
✓ Class I, Zone 0, AEx da ia IIC T4 Ga, Class II, Div 1, Gr. E, F, G
CE
GOST (EAC)
✓ PO Ex da ia I Ma X, 0Ex da ia IIC T4 Ga X
Performance approval
Shipping approval (MED/DNV GL)

Compare with related Products

Get in touch with Dräger

woman black hair

Dräger South Africa (Pty) Ltd.

​Johannesburg:​ ​2​ ​Ruacana​ ​Street,​ ​Waterfall​ ​Commercial​ ​District,​ ​(cnr​ ​Beatty​ ​Street),​ ​Buccleuch,​ ​2090

+27(0)11 059 4200

​Postal​ ​Address:​ ​P.O.​ ​Box​ ​4676​ ​Rivonia,​ ​2128​ ​Republic​ ​of​ ​South​ ​Africa

Dräger South Africa (Pty) Ltd.

​Cape​ ​Town:​ ​​ ​Unit​ ​2,​ ​7​ ​on​ ​London,​ ​7​ ​London​ ​Circle,​ ​Brackengate​ ​Business​ ​Park​ ​Brackenfell,​ ​7561

+27(0) 21 819 3000

​Postal​ ​Address:​ ​P.O.​ ​Box​ ​3677​ ​Tygervalley​ ​7536

Dräger South Africa (Pty) Ltd.

​Durban:​ ​17​ ​Thynk​ ​Industrial​ ​Park​ ​Cnr​ ​Brickworks​ ​and​ ​Queen​ ​Nandi​ ​Drive,​ ​Briardene,​ ​Durban​ ​North,​ ​7561

+27(0)31 812 7900

​Postal​ ​Address:​ ​P.O.​ ​Box​ ​40554​ ​Redhill​ ​4071

Dräger Kenya Ltd

Nairobi:​​ ​​8th​​ ​​Floor​​ ​​Office​​ ​​2,​​ ​​Sanlam​​ ​​Tower,​​ ​​Westlands

+25(0) 47 462 40336

Postal​​ ​​Address:​​ ​​PO​​ ​​Box​​ ​​2380​​ ​​–​​ ​​00606,​​ ​​Nairobi,​​ ​​Kenya.