Ammonia Safety for Use in Zero-Carbon Energy
—Ammonia is key to clean energy solutions, offering great promise for sustainable energy systems. As the use of ammonia expands, it's vital to address the inherent hazards associated with its handling. Highly toxic and flammable, requiring strict safety protocols to protect both people and the environment. Dräger, with extensive experience in ammonia safety, is your go-to partner for mitigating ammonia-related hazards. We provide expert guidance and robust safety solutions, ensuring that your operations are both safe and sustainable.

Empowering Safe Energy Transition: Dräger CleanTech Solutions
Discover how Dräger supports safety and innovation in the rapidly evolving energy sector. This video highlights the essential role of safety and trust in energy transformation. Watch why Dräger, with more than 130 years of expertise, empowers customers worldwide to navigate change with confidence.
Ammonia Hazards
—Ammonia is a flammable gas and can form flammable or potentially explosive compounds in dry air when in gaseous state.
Additionally, Ammonia is a respiratory poison that has a strong irritating and corrosive effect – in gaseous state, but mainly in liquid state.

Toxicity
Exposure to ammonia vapours can cause irritation and damage to the eyes, nose, throat, and lungs. In higher concentrations, ammonia can be fatal. To ensure the safety of workers, appropriate protective measures must be taken, such as gas detectors, personal protective equipment, or ventilation systems.

Flammability
Ammonia is a flammable gas that can be ignited between 14% by volume (lower explosion limit) and 32.5% by volume (upper explosion limit). Spontaneous ignition occurs at 630°C in the presence of sufficient oxygen.

Corrosion
Ammonia is corrosive as it extracts water from its surroundings, creating alkalinity at the points of contact. This can cause skin and eye irritation, chemical burns and damage to the respiratory tract.

Frostbite
Liquid ammonia is often stored in a cold or cryogenic state. Therefore, when handling ammonia, leaks or cold surfaces can lead to frostbite or cold burns. Therefore, when selecting protective equipment, particular attention must be paid to the resistance of materials such as protective clothing.

Water Solubility
Ammonia is highly soluble in water, depending on temperature and partial pressure. Ammonia water poses a long-term danger to aquatic organisms and their environment. Therefore, leaking or spilling ammonia must be avoided at all costs, especially during maritime transport.

Propagation
Ammonia is lighter than air and rises typically. However, when used as a refrigerant, cryogenic NH3 tends to sink when it escapes. Humid conditions can also lead to the formation of ammonia vapour, which is heavier than air. The optimal location of gas detection equipment must be considered case-by-case.
Hazards found in different application areas for Ammonia
Recommended Plant & Personal Safety Solutions
—Get an overview of mobile and fixed gas detection solutions for ammonia detection as well as personal protective equipment and Dräger Services.
Click/tap the tabs below to find out more
Every industrial plant is different. From our extensive experience, we know that fixed fire and gas detection systems are only as effective as the planning which goes in to them. To that end, we work in close collaboration with our customers to provide guidance through the complete process – from consultation through design, realisation and implementation. So, you can achieve the best possible solution for your specific needs

Dräger Polytron® 7000

Dräger Polytron® 8900 UGLD

Dräger Polytron 8200 CAT
The Dräger Polytron 8200 CAT is an explosion-proof high-end transmitter designed for detecting flammable gases and vapours. It uses the catalytic DrägerSensor Ex… DQ. In addition to the 3-wire operation with a 4 to 20 mA analogue output, it also offers HART, fieldbus options and Modbus, allowing you to integrate the transmitter with most control sy…
stems in your gas detection system.
Dräger Flame 1750 IR3 H2
With its triple IR sensor, the Dräger Flame 1750 H2 detects hydrogen-based fires. It offers you high reliability against false alarms and its good measurement performance remains even at extreme temperatures.

Dräger PEX 3000
The Dräger PEX 3000 transmitter detects flammable gases and vapours in concentrations below their lower explosive limit (100 % LEL). It helps you to increase the explosion protection of your plant. Its heat-tone sensor reacts to gas within just a few seconds, and the measurement signal remains particularly stable over the long term.

Dräger REGARD® 3000
Monitor various gases and vapours with the modular Dräger REGARD® 3000 control system. Its multi-coloured status light signals the status of your gas detection system. The controller allows you to combine three different modules: Input, Relay and Gateway module. You can connect up to four analogue transmitters and eight relays in combination.
Find the full range of Dräger Fixed Flame & Gas Detection products
VOICE Hazardous Substances Database
—Dräger VOICE is an essential tool for the safe handling of hazmats. One click and you’ll receive relevant information and specific recommendations of safety equipment for more than 1,500 hazardous substances in its database.

Ammonia is an inorganic compound of nitrogen and hydrogen. A stable binary hydride, and the simplest pnictogen hydride, ammonia is a colourless gas with a distinct pungent smell.
For a full list of substance properties, click the link below.
Find out more from VOICE
Resource Centre
—Discover Dräger’s collection of resources to enhance your understanding of the ammonia safety landscape effectively.
What's New?
Our white papers on three of the main CleanTech energy carriers give you a quick overview of their key safety challenges and solutions to handle them.

Ammonia - a new energy source with special dangers

Hydrogen - safety for the energy source of the future

Methanol in the hydrogen economy - energy carrier with challenging hazards
Further ammonia-related downloads

Hydrogen explosion
The danger of explosion is lurking everywhere. Detecting flammable gases and vapours before they become a hazard takes priority over mechanical and electrical explosion-protection measures.

Confined spaces in the chemical industry
Where no two jobs are the same. Cleaning and maintenance work in confined spaces present particular challenges for safety officers in the chemical industry. This document outlines five basic rules for working safely and efficiently.

How to choose the right emergency escape devices
Life-threatening emergencies can occur at any moment in all kinds of industries. Proper risk analysis and safety planning should consider every possible emergency scenario. Use this emergency escape chart to help you plan.

Cooling with Ammonia
Using ammonia for refrigeration is effective, saves resources and is generally safe. Unpredicted gas leaks, however, cannot be completely prevented. Download to find out what you should keep in mind ...
Got a question? Get in touch
Other Applications
—Around 85% of all ammonia is used to produce synthetic nitrogen fertiliser. A wide range of other applications exist such as refrigeration, mining, pharmaceuticals, water treatment, plastics and fibres, abatement of nitrogen oxides (NOx), etc.

Farming
The direct influence of high ammonia concentrations on the functional or morphologic disturbances in the respiratory tract have been confirmed in experimental investigations.

Refrigeration
For over a hundred years, the alkaline compound of nitrogen and hydrogen which is Ammonia has dominated refrigeration systems in a wide variety of settings and applications.

Fertiliser Production
The most important feedstock for the production of fertilisers is Ammonia. It is synthesised of nitrogen and hydrogen and is one of the most widely used products of the chemical industry.
Want to know more about Dräger application solutions?
Get in touch by completing our short form.
Want to know more? Get in touch
—If you have any questions or queries about Clean Energy, Ammonia and the safety solutions involved - then complete the short form below and we'll get straight back to you.
Other Dräger Clean Energy Solutions
—Follow the links below to find out more about our range of safety solutions in the Clean Tech area.
Get in touch with Dräger
—
Johannesburg: 2 Ruacana Street, Waterfall Commercial District, (cnr Beatty Street), Buccleuch, 2090
Postal Address: P.O. Box 4676 Rivonia, 2128 Republic of South Africa
Cape Town: Unit 2, 7 on London, 7 London Circle, Brackengate Business Park, Brackenfell, 7561
Postal Address: P.O. Box 3677 Tygervalley 7536
Durban: 17 Thynk Industrial Park Cnr Brickworks and Queen Nandi Drive, Briardene, Durban North, 7561
Postal Address: P.O. Box 40554 Redhill 4071
3rd Floor, EY Tower-Canon House, 60 Rangoon Lane, Cantonments City, Accra - Ghana
Postal Address: P.O Box CT 4412, Cantonments, Accra – Ghana.
Digital Address: GL-045-5249





















