Hydrogen chloride (anhydrous)HCl

CAS-No.:
7647-01-0
UN-No.:
1050
EC-No.:
231-595-7
Hazard identification number:
268
Warning sign:
  • 268
  • 1050
Hazard signs
GHS04
GHS05
GHS06
GHS07
  • H: 280
    Contains gas under pressure; may explode if heated
  • H: 314
    Causes severe skin burns
    and eye damage.
  • H: 331
    Toxic if inhaled
  • Melting point:
    -114.8 °C
  • Boiling Point:
    -85 °C
  • Density (at 20 °C, if not notified otherwise):
    0,0016423 g/cm3
  • Ionization:
    12.744 ± 0.009 eV
  • Vapour Pressure (at 20 °C, if not notified otherwise):
    42600 hPa
  •  
diamond 0 1 3
Details
Diamond-Red0Flammability: No explosion danger 
Diamond-Yellow1Instability: Instable when heated 
Diamond-Blue3Health: Very dangerous 
DG-EA:2RE
Also known as:
  • Acids
  • Anhydrous hydrogen chloride
  • chlorane
  • Chlorohydric acid
  • Hydrochloric acid
  • Hydrochloric acid gas
  • Hydrochloride
  • Hydrogen chloride
  • Muriatic acid

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Suitable products for Hydrogen chloride (anhydrous) HCl

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Gas Detection Tubes

Short-term Tubes

Dräger Short-term Tubes

  • Short-term Tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
​Dräger Simultaneous Test Set

Dräger simultaneous test sets

  • ​Dräger Simultaneous Test Set
  • Parallel measurement of five gases
  • Air is simultaneously drawn with Dräger-Tube pump
  • For different combinations of organic and inorganic gases
  • Several different ...
Multi-Gas Detector

Dräger X-act® 7000

  • Multi-Gas Detector
  • ​Opto-electronic analysis system for selective detection of carcinogenic and toxic substances
  • Lab quality measurement in ppb range
  • To be used with Dräger MicroTubes
  • With coupler ...
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • display for clear readability of results
  • can be used in explosive areas
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Fixed Gas Detectors and Sensors

Toxic Gases and Oxygen Detector

Dräger Polytron® 5100 EC

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: with Increased Safety or flameproof
  • Interface: 4-20 mA, Relays
  • IP class: IP 65/66/67
  • Special: displays 
Toxic Gases and Oxygen Detector

Dräger Polytron® 6100 EC WL

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: Wireless
  • IP class: 66/67 and SIL2
  • Special: Wireless 
Toxic Gases and Oxygen Detector

Dräger Polytron® 7000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Intrinsic Safety
  • Interface: 4-20 mA, Bus, HART ®
  • IP class: 66/67 and SIL2
  • Special: Display
Toxic Gases and Oxygen Detector

Dräger Polytron® 8100 EC

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: Increased Safety or flameproof
  • Interface: 4-20 mA, Relays, Bus, HART ®
  • IP class: IP65/66/67 and SIL2
  • Special: ...
Toxic Gases and Oxygen Detector

Dräger PointGard 2100

  • Toxic Gases and Oxygen Detector
  • Sensor: Electrochemical Sensor
  • Installation: Non-explosion proof
  • Interface: 4-20 mA, Relays
  • IP class: IP 66
  • Special: Self-contained gas monitor
Toxic Gases and Oxygen Detector

Dräger Polytron® 3000

  • Toxic Gases and Oxygen Detector
  • ​Sensor: Electrochemical Sensor
  • Installation: with Intrinsic Safety
  • Interface: 4-20 mA
  • IP class: IP66 and SIL1
  • Special: -
Electrochemical Gas Detector

Electrochemical DrägerSensor®

  • Electrochemical Gas Detector
  • ​continuous monitoring of poisonous gases and oxygen
  • compatible with: Polytron 8100, Polytron 7000, Polytron 6100, Polytron 5100, Polytron 3000, PointGard ...

Filters

Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...
Respirator filter Bayonet

Dräger X-plore® Bayonet

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore 3500 ...

Masks

Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...
Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...
Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40
Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • ​Dräger specific bayonet connection – lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...

Powered Air Purifying Respirators and Filters

Filters for PAPR

Dräger X-plore® 8000 Filters

  • Filters for PAPR
  • Particle, gas and combination filters available
  • To be used with powered air purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odour filter

Powered-Air Purifying Respirator

Dräger X-plore® 8000

  • Powered-Air Purifying Respirator
  • Protection without breathing resistance
  • Different breathing filters and head / face pieces available
  • Protection class IP65
  • For Ex zones 1, 2, 21 and 22

Protective Suits

Gas-tight suit

Dräger CPS 7900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit 
  • five suit sizes (S-XXL)
  • side zipper
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 5800

  • Gas-tight suit
  • SCBA worn over the protective suit
  • four suit sizes (M-XXL)
  • diagonal zipper for donning without assistance
  • suit material Zytron® 500, limited use

Gas-tight suit

Dräger CPS 7800

  • Gas-tight suit
  • ​SCBA worn over the protective suit 
  • five suit sizes (S-XXL)
  • diagonal zipper for easy donning and doffing without assistance
  • suit material D-mex, reusable 
Gas-tight suit

Dräger CPS 6900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit 
  • five suit sizes (S-XXL)
  • side zipper for donning without assistance 
  • suit material Umex, reusable
Gas-tight suit

Dräger CPS 6800

  • Gas-tight suit
  • SCBA worn over the protective suit
  • five suit sizes (S-XXL)
  • diagonal zipper for donning without assistance 
  • suit material Umex, reusable
Gas-tight suit

Dräger CPS 5900

  • Gas-tight suit
  • ​SCBA worn inside the protective suit
  • five suit sizes (S-XXL)
  • side zipper
  • suit material Zytron® 500, limited use

Splash Suit

Dräger SPC 4400 / SPC 4800 / SPC 4900

  • Splash Suit
  • Overall with hood (SPC 4400), protective suit with facial cuff (SPC 4800) or full-body protective suit with visor (SPC 4900)
  • CPM (single use) or CLF (limited use)
  • Antistatic version ...
Splash Suit

SPC 4700 with CVA 0700

  • Splash Suit
  • ​Ventilated splash-protective suits
  • Continuous supply of breathing air and cooling airflow (type 3 suit)
  • Coated barrier protection material CPM or carrier fleece material CLF
  • Limited ...

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat