n-ButyyliakrylaattiC7H12O2

Details
CAS-No.:141-32-2
UN-No.:2348
EC-No.:205-480-7
Hazard identification number:39
Warning sign
  • 39
  • 2348
Hazard signs
GHS02
GHS07
Occupational exposure limit
  • HTP-15 min (mg/m3) 53
  • HTP-8 h (mg/m3) 11
  • HTP-15 min (ppm) 10
  • HTP-8 h (ppm) 2
  • H: 226
    Flammable liquid and vapour
  • H: 315
    Causes skin irritation
  • H: 317
    May cause an allergic skin reaction
  • H: 319
    Causes serious eye irritation
  • H: 332
    Harmful if inhaled
  • H: 335
    May cause respiratory irritation
  • H: 412
    Harmful to aquatic life with long lasting effects
Melting point:-65 °C
Boiling Point:148 °C
Density (at 20 °C, if not notified otherwise):0,90 g/cm3
Flash Point:37 °C
Ignition Temperature:275 °C
Vapour Pressure (at 20 °C, if not notified otherwise):5,34 hPa
Lower Explosive Limit:1,2 Vol.-%
Upper Explosive Limit:8 Vol.-%
Hazardous Effects:Ss
Important to know:
Substance included in the Community Rolling Action Plan (CoRAP).
diamond223

Details

Diamond-Red2Flammability: Flammable when warm 
Diamond-Yellow2Instability: Strong chemical reactions 
Diamond-WhiteSpecial: Water suitable as an extinguishing agent 
Diamond-Blue3Health: Very dangerous 
DG-EA:3Y
Also known as:
  • 2-Propenoic acid butyl ester
  • Acrylic acid butyl ester
  • Butyl 2-propenoate
  • Butyl acrylate
  • Butyl ester of acrylic acid
  • Butyl-2-propenoat
  • Butylacrylat
  • n-Butyl propenoate

Suitable products for n-Butyyliakrylaatti C7H12O2

Whether portable gas detectors, gas detection tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.

Portable Gas Detectors and Sensors

Multigas detector

Dräger X-pid® 9000/9500

  • Multigas detector
  • ​Selective VOC gas detection
  • For frequent testing of toxic & carcinogenic substances
  • Laboratory quality results in very low concentrations
  • Benzene measurement starting from 50 ...

Gas Detection Tubes

Short-term Tubes

Dräger Short-term Tubes

  • Short-term Tubes
  • ​results are directly shown at the end of the measurement process
  • spot measurement for more than 500 different gases 
  • short measurement time: between 5 seconds to 15 ...
Sampling Tubes

Dräger Sampling Tubes and Systems

  • Sampling Tubes
  • ​analysis of the sample in a laboratory
  • measurement of complex compounds and mixtures of substances possible 
  • detection of low concentrations possible 
Automatic tube pump

Dräger X-act® 5000 Basic

  • Automatic tube pump
  • ideal for a high number of strokes
  • display for clear readability of results
  • can be used in explosive areas
Manual tube pump

Dräger accuro

  • Manual tube pump
  • for spot measurements with a limited number of strokes
  • integrated stroke counter for safe control
  • easy to operate with one hand
  • can be used in explosive areas 

Filters

Respirator filter Rd40

Dräger X-plore® Rd40

  • Respirator filter Rd40
  • ​standard thread connection Rd40 according to EN 148-1
  • robust aluminium housing
  • to be used with half and full face masks with standard thread connection Rd40 according to EN ...
Respirator filter Bayonet

Dräger X-plore® Bayonet

  • Respirator filter Bayonet
  • Dräger specific Bayonet connection
  • lateral position of the filters for an unrestricted field of vision and even weight distribution
  • to be used with X-plore 3300 or X-plore 3500 ...
Respirator filter Rd90

Dräger X-plore® Rd90 Filters

  • Respirator filter Rd90
  • ​Dräger specific Rd90 connection
  • robust aluminium housing
  • to be used in combination with X-plore 4700 half masks

Masks

Single-filter full-face mask

Dräger X-plore® 6300

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of PMMA
  • to be used with all filters with standard thread connection Rd40
Twinfilter full-face mask

Dräger X-plore® 5500

  • Twinfilter full-face mask
  • ​Dräger specific bayonet connection – lateral position of the filters 
  • EPDM mask body, visor made of triplex or PC
  • to be used in combination with X-plore Bayonet ...
Twin-filter half-face mask

Dräger X-plore® 3300/3500

  • Twin-filter half-face mask
  • ​Dräger specific bayonet connection (twin-filter system)
  • mask body made from Soft-TPE or DrägerFlex material (silicon free)
  • to be used with X-plore Bayonet ...
Single-filter half-face mask

Dräger X-plore® 4700

  • Single-filter half-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • mask body made from TPE (universal size) or silicone (two sizes)
  • to be used with all filters with standard thread ...
Single-filter full-face mask

Dräger Panorama® Nova

  • Single-filter full-face mask
  • ​different thread connections: RA thread connection Rd40, PE thread connection M45x3, ESA plug-in connector, P Dräger plug-in connection
  • EPDM or silicone mask body, ...
Single-filter full-face mask

Dräger X-plore® 6530

  • Single-filter full-face mask
  • ​standard thread connection Rd40 according to EN 148-1
  • EPDM mask body, visor made of triplex or PC
  • to be used with all filters with standard thread connection ...

Puhallinsuojaimet ja suodattavat hengityksensuojaimet

Filters for PAPR

Dräger X-plore® 8000 Filters

  • Filters for PAPR
  • Particle, gas and combination filters available
  • To be used with powered air purifying respirator X-plore® 8500 or 8700 (EX)
  • Optional pre- and odour filter

null

Dräger X-plore® 8000

Get in touch with Dräger

If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.

Haluatko lähettää meille liitteen? Lähetä se meille sähköpostilla tästä: asiakaspalvelu@draeger.com

Discover more: Dräger VOICE - The hazmat-based safety product finder

You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guides you, according to a substance, to suitable gas detectors and protection equipment. Give it a try!

VOICE Hazmat