WiTOF is the first wireless NMT monitor.

Idmed voordelen ENG
Real-time control of the neuromuscular blockade

As a true monitor of the neuromuscular block, the WiTOF has a graphic interface for precise control of its depth. It allows to visualize and anticipate the recovery and to manage well the antagonism. The setting up of events gives the possibility to alert the user at any time of the actual level of the patient blockade.

Witofscreen
Secure wireless transmission

WiTOF‘s wireless sensors simplify patient accessibility and allow for optimal positioning of the monitor in the operating theatre. IDMED has provided the WiTOF with a set of algorithms and protocols that guarantee a wireless communication that is both robust and secure. Accessibility to the hand or foot of the patient is no longer a default choice but a decision of the practitioner.

Witofarm
Intuitive handling

Its sensors integrate electrodes sockets ideally spaced to control the inter-electrode distance to ensure the optimal electrical stimulation. They continuously monitor the impedance of the patient and are illuminated with colored flashes in order to instantly validate the quality of the stimulations.

Witoffoot
WiTOF solves the problems of monitor-patient connectivity and offers total control of the depth of the neuromuscular blockade.

SENSORS

Anesthesia teams will manage cases with ease and efficiency with the wireless sensor. All the WiTOF sensors make use of three-dimensional accelerometry for the actual measurement of movements with advanced accuracy and to dispense with any calibration process.

Witofarm

Wireless 3D Hand sensor

  • Simplified accessibility to the hand or the foot of the patient
  • The sensor is charged on the station in a built-in holder
  • Controlled gap between the electrodes
  • Impedance light signal on the sensor
Witoffoot

Wireless 3D Foot sensor

TECHNICAL DATA

Simulation ENG

  • TOF (Train Of Four)
  • Automatic TOF
  • ATP (Automatic TOF-PTC)
  • PTC
  • DBS (3.3, 3.2)
  • Single Twitch (0,1 ; 1 Hz)
  • Tetanus 50 Hz / 100 Hz
  • Trend curve
  • Continuous monitoring
Measurements eng

  • TOF mode : T4/T1
  • TOF mode : T4/Tref
  • TOF mode : count
  • PTC mode : count
  • DBS mode : count
Egonomics eng

  • 3D accelerometer sensor hand and foot
  • No calibration required
  • Adjustable stimulation current
  • Monitoring the depth of blockade
  • Event management
  • Automatic sleep mode
  • Fixing clamp
  • Connectable monitor
  • Mains power supply
Standards eng

  • EN 60601-1 (Medical Electrical Equipment)
  • EN 60601-1-2 (EMC)
  • 2A CE Class (CE 0459)

Données techniques